Washington Public Power, Supply System A JOINT OPERATING AGENCY P. O, BOX 90$
3000 GEO. WAEHINCVON WAV RICHI.ANO, WASHINCTON 99352 PHONE (509) 375 5000 January 29, 1980 Mr. Brian K. Grimes, Director Emergency Preparedness Task Group Office of Nuclear Reactor Regulations U. S. Nuclear Regulatory Commission Washington D.
C.
20555
Dear Mr. Grimes:
Subject:
EMERGENCY EVACUATION TIMES In response to your requests dated November 29 and December 26, 1979 concerning emergency evacuation
- times, we are submitting the enclosed map, overlay, table and basis of methodology regarding estimates for evacuation of various areas around WNP 1, 2 and 4 located on the Hanford Reservation in Richland, Washington.
We will be sending similar information for the WNP-3/5 sites under separate cover when it is compiled.
The information provided is the best presently available.
Washington Public Power Supply System has initiated a study of evacuation feasi-bility for the population around the Hanford site with completion expected in May 1980.
Updated information will be provided at that time.
Very truly yours, D. L.
RENBERGER Assistant Director Technology mg Attachment(s)
V L
q <
'~I 5gII 8002060 Sg j dig(/ //
I p
u I
v J
POPULATION, POPULATION DENSITY 5 EVACUATION TIMES HNP 1, 2.&, 4 Distance Sector Residential Population Population Density (For population areas within sector)
Estimated Evacuation Time 2 ml 2-5mi 2-5mi 5 - 10 mi 5 - 10 mi 5
10 mi 5 - 10 mi all
¹ 2
all others 0
82 persons 0
275 persons 533 persons 1333 persons 0
0
.10 persons/mi2 10 persons/mi 10 persons/mi 400 persons/mi2 0
0 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 0
3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> 5'ours 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> '
!i
EVACUATION TIMES WNP1,254 s
ti Two estimates are requested in each of the areas defined in item 1 for a general evacuation of the population (not including special facilities).
A best estimate is required and an adverse weather estimate is required for movement of the population.
~Res ense:
Attached is a table of populations, population densities and evacuation times.
A map with an overlay of the 2 mile, 5 mile, and 10 mile sectors with times indicated is also attached.
The evacuation times are for normal weather conditions and include shutdown and mobilization times for farms which takes longer than in densely populated areas.
Adverse weather conditions such as a blizzard could make evacuation impos-sible.
However, adverse weather conditions due to hurricanes, tornadoes, snow storms, etc.,
have been analyzed by the EPA to determine their effect on evacuation times.
This has been reported in EPA document 520/6-74-002, "Evacuation Risks - An Evacuation" which states:
"Data analysis and literature reviewed in the bibliography do not reveal any correlation between time of day, weather conditions, population size, area size, area type, road conditions, time lapse before onset of incident, use of plans, or the nature of the incident and the time required to evacuate a population group."
For each of the sectors shown on the table and the overlay to the map, the following summary is given.
The evacuation times agree with the esti-mates of the local Director of Emergency Services who was contacted in regard to this request.
2 Mile Radius:
There is no residential population living within two miles of the site which is located on the Hanford Reservation.
5 Mile Radius:
Only Sector b
2 contains a residential population within the five mile radius.
This populous is located east of the Columbia River three miles and beyond from the site.
The Benton-Franklin counties Nuclear Incident Response Plan contains a phone list of all the residents within six miles of the site, which includes this area of 82 in population.
Using the list, it is estimated that this popula-tion could be evacuated within one hour's time.
~
~
EVACUATION TIMES
. Page 2
10 Nile Radius Sector 1
This is a farming area with all of the residents living east of the Columbia River in Franklin County.
The population of the Sector is 275.
An approximation can be made of the time required to evacuate the affected areas based on the load capacity of roads.
EPA estimates indicated that 1,000 vehicles could be moved per lane per hour, and as many as 4,000 cars per lane per hour have been observed during actual evacuations.
- Clearly, there are no obstacles in moving only 274 persons, and a conservative time estimate of five hours is given.
This estimate is also in agreement with those that can be derived from EPA 520/1-75-001, "Manual of Protective Action Guides and Protective Actions For Nuclear Incidents", Table 1.5 Approximate Range Time Segments Making Up The Evacuation Time.
Sector 2
This is also a farm area with similar population density to Sector 1, but with a total population of 533.
This area has two main roads to be used during an evacuation, and a conservative estimate of five hours time is given.
This includes the concurrent evacuation of the inner adjacent sector.
Sector 3
It is estimated that this sector, North Richland, can be evacuated in five hours.
The following formula from EPA 520/6-74-002, is the basis for this time.
Evacuation time:
log (hours)
= 1.30571-0.21243 log (persons/square miles).
The population of this sector is 1333 with a population density of 400 persons/square mile for the small area of the section which is populated.
This falls within the range of applicability for the formula.
(The other sector's population density is too low for valid use of the formula.)
Sector 4
There is no residential population living in this area (Hanford Reservation).
~
~
I J
l t
I I
~
s
~
EVACUATION TINE Page 3
guestion 2:
The total time required to evacuate special facilities (e.g., hospitals within each area must be specified (best estimate and adverse weather).
~Res onse:
There are no special facilities located within 10 miles of WNP-2.
The time required for confirmation of evacuation should be indicated.
Confirmation times may consider special instructions to the public (e.g.,
tying a hankerchief to a door or gate to indicate the occupant has left the premises).
~Res onse:
Present plans are to notify residents to evacuate by use of the public telephone system.
Using this method, confirmation would be received when the notification call is completed.
These confirmation times are included in the estimates given.
s i
'I:
Where plans and prompt notification systems have not been put in place for areas out to about 10 miles, estimates of the times required to evacuate until such measures are in place for the plume exposure emergency planning zone (EPZ) should also be given.
Notification times greater than 15 minutes should be included in the evacuation times and footnoted to indicate the notification time.
~Res onse:
Plans and methods of prompt notification will be in place prior to the fuel load of WNP-2.
s i
5:
Where special evacuation problems are identified (e.g., in high population density areas),
specify alternative protective actions, such as sheltering, which would reduce exposures and the effectiveness of these measures.
~Res onse:
No area is identified where special evacuation problems may exist.
As can be seen on the attached table and map overlay, all areas within the 10 mile EPZ have very low populations.
g
~
~
I
~
~ I(,
I ~
C (
I
'I
~
~
~
I
~
I ~
~
EVACUATION TIME Page 4
guestion 6:
A short background document should be submitted giving the methods used to make the estimates and the assumptions made including the routes and methods of transportation used.
This document should also note the agree-ment or areas of disagreement with principal local officials regarding these estimates.
~Res ense:
Private vehicles will be the primary means of transportation for evacuees.
Available types of mass-transportation include school busses and trucks.
The County Emergency Services Director can arrange for such transportation, if required.
5 Mile Radius The primary relocation center for the Franklin County population living within five miles of the site, if an evacuation out to this distance was initiated, is Basin City Elementary School.
The residents of this-area (Ringold) will proceed northeast on County Road 170 or east on Ringold or Eltopia Roads to Glade North Road, then north to Basin City, approximately ll miles from the site.
The roads available for evacuation from this area are two-lane, gravel surfaced which feed, approximately each mile, into improved two-lane roadways.
Sector 1
Residents of this sector will proceed east on the Russell and Basin Hill
- Roads, then north on County Road 17, and east on the Hendricks Road to the vicinity of Connell approximately 25 miles from the site.
Sector 2
Residents of this sector will proceed south on the Taylor Flats or Glade Roads to the vicinity of Pasco approximately 15 miles from the site.
Sector 3
Persons located west of Stevens Drive will proceed south on Highway 240 to Highway 224, then west to the Elks lodge in West Richland.
Persons located east of Stevens Drive wi 11 proceed south on Stevens Drive to Van Giesen, then west to the Elks lodge in West Richland.
The Elks lodge is approxi-mately 12 miles from the site.
There are alternate routes and relocation centers for each of these sectors described in the Benton-Franklin Nuclear Incident Response Plan.
All information presented in this letter is in agreement with Mr. Don Minnock, Benton County Director of Emergency Services.
h1r. Minnock also directs the Franklin County nuclear response planning effort.
4 l
gvggugtyi~
Taws4 f Stc >L~l <
wNN 4t l
l
~li WiX
>> ~
CI r
ItI rel>>r>>/q
/
ee'XAI el I
I s
I A R>>
~ >>>>,>>,
eeeec i I
I I
t I
l
>>)
C(>>/ss aw I
I>> \\>>ere>>i tt I
I
/
/
Ill
-e>>>>>>it II IRRICOe "III I
ce>>>>>>>> l~
I'>>/I, I I
S i.
I
"~
~
= ~
II.,>>/
'c
'wkr
~. ~
c I
Ol r
r
/
/'
e I
l>>
r
/
BENTON COUNTY
- ctn, C," I >><
'i
",~I~
weeco
~
~
te/IIISR I)R I +
\\CS>>>>I j/
WIRC$
I
~'>>>>l md'.
I
~4
/ I
/O ~
r 1
S i ~
Il
'Cl5'ir Ie>>reaR>>g COUNTY I
c l
(
(
II er>>>>P I
I
>. ~
I(
l III I!I FRANKL e>>
Cg>>( ~ >>e
~ t ll>>M4 ii i>> rr
'/ I q /C(fc 0 te(fy a, I' (o,'(>> c
~
~
YCI seecc l
I
\\
l
~ ~
~ I
~
~
)f g
4 4
4
~F
~
f
/
l~
~ ~
I
- r r
lI
~ I 4 4
.g.< - ~c.
+ ~
ay 0
~
~
RKGULATO INFORMATlON DISTRIBUTION ~TEM (RIDS)
I ACCESSION NBR!8002060591, DOC ~ DATE! 80/01/29 NOTARIZED!
NO PACK 50 397 HPPSS HucIear Projecti Unit 2i'Aasliington Public Powe
" " "50 460 Hl P88 Nuc)ear Projectg Onit ig Hash'ington Pub)'ic Powe 50 513 NPPSS Nuclear Projecti Unit 4p washington Pub'lie F'owe AUTH,AAMK-ALlTHOR AFP ILiATION REABERVERgP.L.
Nashington I'ubI,ic-"l,ower Supply System RECTI
~ AAME AECIPIENT AFFILlATIOH GRIMES/ B k Kmer gency Preparednessr Task Force COPIES L'tTR'EACL i
5 i
0 RECIPIENT ID CODE/hlAMK AD L.4aJR LAL.tu@~ Q) 02 NRC PDR Oe UPERA 'LIC BR 15 UAB-- ""- '
i2 STRUC ENG'R i5 AKAC SYS BA i7 CORE PERF SR CONTAIN SYS P'ONER SYS BR 26 ACCENT AALIYS 28 RAG ASMt'H AD F'R ENG AD AEAC, SAFETY DIREClOR AHA "
INTERNAL,e 0
~
~ ~ >>
a rrm r
I g g
rrr 09 SKOSH'IKN BR 11 HECR EAb SR.
13 MATLT ENG, SR 16 aAaL:YSZS BR i8 AUX S78 BR 20 I L
C SYS BR 22 AD SlTE TKCR 27 El FL> TAT 878 29 KIAlfNOOD AD PL'ART"8VS AD SlTE-AaPSIS RYDRO METE'UR-UA IIELD" 1
1 2
1 2
1ii i
i 0
1 1
ii 0
i 0
2 0
1i i
i i
1i 0
0 0
SUBJECT:
Submits map overlayitables L basis 'of methodology re estimates for evacuation 'times in response to 791226 ltr.
Evacuation feasibility study will be completed in May 1980, One'versize
'map enc:I s
DISTRIBUTION CODE:
SDOIS COPIES RECEIVED:LTR 1 ENCLi SIZE" T$ 'fLEi PSAR/FSAR AMDTS and AeIated:Correspondence NOTES)
Ph
~
V0 L
L
,A H RECIPIENT 80u4VL80P IES ID COOK/NAMF~7 I:fTR ENCL ACTION!
05 PA %, Lynch~
1 1
Bc~A les A
i 0
DOCKKT 05000397 O5OO0II60 05000518 EXTERNALS 03 LPDR 30 ACRS 1
1 10 1lI 04 NSIC Ver ~ ~
~ G'a(uncs MVXI pgOrrPSITr
~~IEIEZS'- PIE,P, Sg
&08@ 0-ag k)opg($
8 19SO TOTAL NUMBER OF COPIES REQUIRED:
LT R
&1 ENCL 49
~I1+( I
'I O. 8l
.0j 4)y
~
$ f g lp Q
~
f3
< ~) l~gjg(1)44 I
~ $
>f$ "i
~ 5,"
(f~
Ey 44 Q. lg f
'N t
s 1
II
~
p P'
(~
i5 W
pi P)- e~
~
~
W f QeQlQ
~
~
~.-'
L 4