ML17269A100
| ML17269A100 | |
| Person / Time | |
|---|---|
| Site: | Arkansas Nuclear |
| Issue date: | 09/20/2017 |
| From: | Office of Nuclear Material Safety and Safeguards |
| To: | |
| Beardsley M | |
| Shared Package | |
| ML17269A097 | List: |
| References | |
| Download: ML17269A100 (4) | |
Text
Revisions to Transportation Safety Requirements and Harmonization with International Atomic Energy Agency Transportation Requirements; Including Corrections 10 CFR Part 71 (80 FR 33987, Published June 12, 2015 and 80 FR 48683, Published August 14, 2015)
RATS ID: 2015-3 Effective Date: July 13, 2015 Date Due for State Adoption: July 13, 2018 ARKANSAS CROSS-REFERENCE Change to NRC Section Title State Section Comp.
Category Comments
Revised Purpose and Scope RH-3002.d.1.
D No change needed to d.1.; revised other Comp D paragraphs in RH-3002.
§ 71.4 New Definition: Contamination RH-3100.
[B]
Defn of Act is Comp D; Certificate of Compliance Comp Comp [B]
§ 71.4 Revised Definition: Criticality Safety Index (CSI)
RH-3100.
[B]
§ 71.4 Revised Definition:
Low Specific Activity (LSA) material RH-3100.
[B]
§ 71.4 Revised Definition: Special form radioactive material RH-3100.
[B]
§ 71.4 Revised Definition: Uranium - natural, depleted, enriched RH-3100.
[B]
§ 71.6 Revised Information Collection Requirements:
OMB Approval NA D
§ 71.14(a)(1) - (a)(3)
Revised, New Exemption for low-level materials RH-3202.a.-c.
[B]
2 Change to NRC Section Title State Section Comp.
Category Comments
Revised Exemption from classification as fissile material RH-3203.d.
[B]
Also revised introductory text
- Revised, Removal of Brackets on Compatibility Category.
General license: NRC approved package RH-3301.
B
§ 71.19 Revised Previously approved package NA NRC
- Revised, Removal of Brackets on Compatibility Category General license: Use of foreign approved package RH-3304.
B Also revised RH-3305. (§71.21) and RH-3306. (§71.22) - both Comp [B]
Revised Contents of application NA NRC
§ 71.38 Retitled, Revised Renewal of a certificate of compliance NA NRC
§ 71.70 New Incorporations by reference NA NRC
§ 71.75 Revised Qualification of special form radioactive material NA NRC
§71.85(a) - (c)
- Revised, Compatibility Change Preliminary determinations RH-3502.
NRC (was [B])
Deleted par. a.-c.; also, revised RH-3500. (§71.81) - Comp D
3 Change to NRC Section Title State Section Comp.
Category Comments
New Preliminary determinations RH-3502.
B Referenced 10 CFR regarding previous par. a.-c.
- Revised, Compatibility Change Records RH-3506.a.
C (was D)
Compatibility Change Records RH-3506.
NRC (was D)
Deleted previous RH-3506.b.
§ 71.91(c) and (d)
Compatibility Change Records RH-3506.b.
and c.
C (was D)
Also revised RH-3507. (§71.93) and RH-3508. (§71.95) - both Comp D
- Revised, Compatibility Change Quality assurance requirements RH-3600.a.
C**
(was D or C)
Also deleted previous RH-3600.d.
(§71.101(f)) - Comp D
§ 71.101(b) and (c)(1)
Compatibility Change Quality assurance requirements RH-3600.b.
and c.
C**
(was D or C)
Revised Quality assurance requirements NA NRC
Compatibility Note Revised Quality assurance requirements RH-3600.d.
C**
- Revised, Compatibility Change Quality assurance organization RH-3601.a.
C**
(was D or [C])
4 Change to NRC Section Title State Section Comp.
Category Comments
Compatibility Note Revised Quality assurance organization RH-3601.b.
C**
No change needed to par. b.
§ 71.106 New Changes to quality assurance program RH-3602.e.
C Also revised RH-3602.a. (§71.105(a))
- Comp C
- Revised, Compatibility Change Quality assurance records RH-3607.
C**
(was D or C)
Also revised RH-3603., RH-3604., RH-3605., RH-3606., and RH-3608. - all Comp C Appendix A Revised Determination of A1 and A2 Appendix A to Section 4
[B]
Appendix A, Table A-1 Revised A1 and A2 Values for Radionuclides Appendix A to Section 4, Table A-1
[B]
Appendix A, Table A-2 Revised Exempt Material Activity Concentrations and Exempt Consignment Activity Limits for Radionuclides.
Appendix A to Section 4, Table A-2
[B]
Appendix A, Table A-3 Revised General Values for A1 and A2 Appendix A to Section 4, Table A-3
[B]
- Note: §71.101(g) indicates that QA programs for industrial radiography Type B package users are covered by §34.31(b). It also indicated that this section satisfies §71.17(b) and therefore will satisfy those sections referenced in this provision (§§71.101 through 71.137)