July 29, 1999

~

Dr. Robert C. Mecredy

Vice President, Ginna Nuclear Operations

Rochester Gas and Electric Corporation

89 East Avenue

Rochester, New York 14649

SUBJECT:

NRC INTEGRATED INSPECTION REPORT 50-244/99-04

Dear Dr. Mecredy:

This letter transmits the results of safety inspections conducted by NRC inspectors at the Ginna

Nuclear Power Plant from May 17 through June 27, 1999. At the conclusion of the inspection,

the findings were discussed with Mr. J. Widay and others of your staff.

During the six weeks covered by this inspection, we noted generally good overall performance.

However, we are concerned by a series of unplanned radiation exposure events that resulted

from deficiencies in the implementation and oversight of radiological controls. These events

'were properly addressed

within the corrective action program when brought to the attention of

plant management,

but the corrective actions following the individual events were not effective.

In addition, the overall series of events represented

an indifference to proper radiological

controls and precautions on the part of the individual radiation workers, radiation protection

technicians, and direct supervision involved.

Based on the results of our review of these unplanned radiation exposure events, the NRC has

determined that a Severity Level IVviolation of NRC requirements occurred.

This violation is

being treated as a Non-Cited Violation (NCV), consistent with Appendix C of the enforcement

policy. The NCV.is described in the subject inspection report. Ifyou contest the violation or the

severity level of the NCV, you should provide a response within 30 days of the date of this

inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, D.C. 20555-0001, with copies to the Regional

Administrator, Region 1, and the Director, Office of Enforcement, United States Nuclear

Regulatory Commission, Washington, D.C. 20555-0001, and the NRC Resident Inspector at

Ginna Station.

I

'P908030i3i

990729

PDR

ADQCK Q5QQQ244

8

PDR

]

o'

Dr. R. C. Mecredy

2

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and its

enclosure will be placed in the NRC Public Document Room (PDR).

Sincerely,

Original Signed By:

Michele G. Evans, Chief

Projects Branch No. 1.

Division of Reactor Projects

Docket No.: 50-244

License No: DPR-18

Enclosure:

Inspection Report 50-244/99-04

cc w/encl:

P. Wilkens, Senior Vice President, Generation

Central Records (7 copies)

P. Eddy, Electric Division, Department of Public Service, State of New York

C. Donaldson, Esquire, State of New York, Department of Law

N. Reynolds, Esquire

F. William Valentino, President, New York State Energy Research

and Development Authority

J. Spath, Program Director, New York State Energy Research

and Development Authority

Dr. R,. C. Mecredy

Distribution w/encl:

Region

I Docket Room (with concurrences)

PUBLIC

NRC Resident Inspector

Nuclear Safety Information Center (NSIC)

H. Miller, RA/J. Wiggins, DRA

D. Screnci, PAO Region

M. Evans, DRP

W. Cook, DRP

R. Junod, DRP

Distribution w/encl (VIAE-NIAIL):

M. Tschiltz, Rl EDO Coordinator

E. Adensam, NRR

S. Bajwa, NRR

G. Vissing, NRR

M. Campion, ORA

R. Correia, NRR

Inspection Program Branch, NRR (IPAS)

DOCDESK

DOCUMENT NAME:G:)BRANCH1EGINSTUFRgin9904.wpd

To receive a copy ofthis document, Indicate In the box: "C ~ Copy without attachment/enciosure

E ~ Copy with attachment/enciosure

N"= No

OFFICE

RI/DRP

NAME

COsterholtz

RI/DRP

MEvans

tir

DATE

@99

99

OFFICIALRECORD COPY