Provides More Detailed Description of Basis for Proposed Setpoint Language Contained in 970929 Application for Amend, Per 980428,0513 & 20 & 0603 Telcons W/Nrc Re Change to Main Steam Isolation Setpoint.Revised TS Pages Encl
Date released: 04/30/2018 Download: ML17265A313


Proposed Tech Specs Basis Re Main Steam Isolation Setpoint
ML17265A315
Person / Time
Site: Ginna 
Issue date: 06/04/1998
From:
ROCHESTER GAS & ELECTRIC CORP.
To:
References
Download: ML17265A315 (4)
Provides More Detailed Description of Basis for Proposed Setpoint Language Contained in 970929 Application for Amend, Per 980428,0513 & 20 & 0603 Telcons W/Nrc Re Change to Main Steam Isolation Setpoint.Revised TS Pages Encl
ML17265A312
Person / Time
Site: Ginna 
Issue date: 06/04/1998
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To: VISSING G S
NRC (Affiliation Not Assigned), NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17265A312 (15)