ML17264B114

From kanterella
Jump to navigation Jump to search
Advises of Planned Insp Effort Resulting from Licensee Prp Reviews.Details of Insp Plan at Plant for Next 6 Months Encl
ML17264B114
Person / Time
Site: Ginna 
Issue date: 11/21/1997
From: Doerflein L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
References
NUDOCS 9712010052
Download: ML17264B114 (6)


Text

mme r music,x.

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDE)

ACCESSION NBR:9712010052 DOC.DATE: 97/11/21 NOTARIZED: NO DOCKET.5 FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

05000244 AUTH.NAME AUTHOR AFFILIATION DOERFLEIN,L.T.

Region 1 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION MECREDY,R.C.

Rochester Gas

& Electric Corp.

SUBJECT:

Advises of planned insp effort resulting from licensee PRP reviews.

DISTRIBUTION CODE:

IE01D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

T 05000244K RECIPIENT ID CODE/NAME PD1-1 PD COPIES LTTR ENCL 1

1 RECIPIENT ID CODE/NAME VISSING,G.

COPIES LTTR ENCL 1

1 0

INTERNAL: AEOD/SPD/RAB DEDRO NRR/DISP/PIPB NRR/DRPM/PECB NUDOCS-ABSTRACT OGC/HDS3 EXTERNAL: LITCO BRYCE,J H

NRC PDR 1

1 1

1 1

1 1

1 1

1 1

1 NRR/DRCH/HHFB NRR/DRPM/PERB OE DIR RGN1 FILE 01 NOAC NUDOCS FULLTEXT 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 D

0 N

NOTE TO A~L "P.:DS" RE ZPZENTS:

PLEASE HELP US.O REDUCE 'FEAST~

'-"V:" YOUP NA~"" OP. ORGAN ~dPZON REMOVED FROM DZSTRZBUTZON LISTS OR REDUCE TH ha~

.. O.

COP

-S R-C"

'v'E<< BY YOU OR YOUR ORGMv ~ATZONv CONTACT THE DOCUMENT CONTROL DESK (D D)

ON EXTENSION 4'5-2083 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 18 ENCL 18

November 21, 1997 Dr. Robert C.

Mecredy Vice President, Ginna Nuclear Operations Rochester Gas and Electric Corporation 89 East Avenue Rochester, New York 14649

SUBJECT:

PLANT PERFORMANCE REVIEW (PPR) - GINNA

Dear Dr. Mecredy:

On October 20, 1997, the NRC staff completed the semiannual Plant Performance Review (PPR) of Ginna.

The staff conducts these reviews for all operating nuclear power plants to develop an integrated understanding of plant performance.

The results are used by NRC management to facilitate planning and allocation of inspection resources.

The PPR for Ginna involved the participation of all technical divisions in evaluating inspection results and safety performance information for the period March 1997 through October 1997.

PPRs provide NRC management with a current summary of licensee performance and serve as inputs to the NRC Systematic Assessment of, Licensee Performance (SALP) and senior management meeting (SMM) reviews.

This letter advises you of our planned inspection effort resulting from the Ginna PPR review. It is provided to minimize the resource impact on your staff and to allow for scheduling conflicts and personnel availability to be resolved in advance of inspector arrival onsite.

The enclosure details our inspection plan at Ginna for the next 6 months.

Resident inspections are not listed due to their ongoing and continuous nature.

We willinform you of any changes to the inspection plan.

If you have any questions, please contact me at (610) 337-5378.

Sincerely, Original Signed by:

Lawrence T. Doerflein, Chief Projects Branch 1

Division of Reactor Projects Docket No. 50-244 License No.

DPR-18

Enclosures:

Ginna Inspection Plan 97i20i0052 97ii2i PDR ADOCK 05000244 8

PDR lillilllllll(lllllll!!I!!!ll!!Ill!

OFFICIAL RECORO COPY

Robert C. Mecredy cc w/encl:

R. Smith, Senior Vice President, Customer Operations Central Records (7 copies)

P. Eddy, Director, Electric Division, Department of Public Service, State of New York State of New York, Department of Law N. Reynolds,, Esquire F. William Valentino, President, New York State Energy Research and Development Authority J. Spath, Program Director, New York State Energy Research and Development Authority

Robert C. Mecredy Distribution w/encl:

H. Miller, RA/W. Axelson, DRA (1)

Region I Docket Room (with concurrences)

PUBLIC NRC Resident Inspector Nuclear Safety Information Center (NSIC)

J.

Wiggins, DRS L. Nicholson, DRS L. Doerflein, DRP T. Moslak, DRP R. Junod, DRP R. Ragland, DRS L. Prividy, DRS M. Oprendek, DRP Distribution w/encl (VIA E-MAIL):

K. Kennedy, Rl EDO Coordinator S. Bajwa, NRR G. Vissing, NRR M. Campion, ORA Inspection Program Branch, NRR (IPAS)

R. Correia, NRR F. Talbot, NRR DOCDESK DOCUMENT NAME: G:tBRANCH1ttGNLTR109.PPR To receive a copy of this document, indicate in the box:

"C" = Copy without attachment/enclosure "E" "-Copy with attachment/enclosure "N" = No copy OFF ICE Rl/D NAME TMoslak DATE 1 1

/97 RI/DRP LDoerflein 11/:t /97 OFFICIAL RECORD COPY

GINNA INSPECTION PLAN" INSPECTION PROCEDURE TITLE/PROGRAM AREA PLANNED INSPECTION DATES TYPE IP 81700-2 Physical Security 1 2/01/97 Core Inspection IP 37550 IP 64704 Engineering Fire Protection Program Review 1 2/08/97 01/05/98 Core Inspection Core Inspection IP 40500 Effectiveness of Licensee Controls in Identifying, 01/19/98 Resolving, and Preventing Problems Core Inspection IP 62706 Maintenance Rule 03/1 6/98 Core Inspection

" CORE RESIDENT ACTIVITIESNOT INCLUDED