CATEGORY 1 REGULATO INFORMATION DISTRIBUTION

~TEM (RIDS)

ACCESSION NBR:9602130072 DOC.DATE:'TARIZED: NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

AUTH.NAME AUTHOR AFFILIATION WALDEN,J.V.

Rochester Gas a Electric Corp.

WIDAY,J.A.

Rochester Gas~& Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION DOCKET I 05000244

SUBJECT:

Monthly operat'or Jan 1996 for R.E.

Ginna Nuclear Power Plant 960207 1

.4 DISTRIBUTION CODE:

IE24D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: Monthly Operating Report (per Tech Specs NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

A 050'00244 E

RECIPIENT ID CODE/NAME PD1-1 PD INTERNAL: AEOD/SPD/RRAB NRR/DRPM/PECB EXTERNAL: LITCO BRYCEgJ H

NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME JOHNSON,A FILE CENTER RGNl NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 D

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTEt CONTACT THE DOCUMENT CONTROL DESKi ROOM OWFN SD-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:,'TTR 9

ENCL

~ 9;.

1

0 if ISSS q

fffffffffffff EÃ 1 fffffffffffff r(r rti~ oal ~

/

>orr SLAM ZP ROCHESTER GAS AND ELECTRIC CORPORATION o e9 EAST AVENUE, ROCHESTER, N.Y. 14649-0001 TKLKPHONK ARKA COOK 7IK 546-2700 GINNA STATION February 7,

1996 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Monthly Report for January, 1996 Operating Status Information R.

E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Sir:

Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report for Ginna Station for the month of January, 1996.

Very truly yours,

a. Lj s

h A. Wi Plant Manager JAW:tjn Attachments c:

Mr. Thomas T. Martin NRC. (1) 3.30065 r

9602i30072 960i31 PDR ADOCK 05000244 R,PDR g

l

OPERATING DATAREPO COMPLETED BY:

50-244 Februa 7 1996 John V. Walden TELEPHONE (716) 7714588

1. Unit Name:

R.E. GINNANUCLEAR POWER PLANT

2. Reporting Period:

Janua 1996 3.

Licensed Thermal Power (MWt):

1520 4.

Nameplate Rating (Gross MWe):

490 5.

Design Electric Rating (Net MWe):

470 6.

Maximum Dependable Capacity (Gross MWe):

490 7.

Maximum Dependable Capacity (Net MWe):

470 8.

IfChanges Occur in Ca pacity Rating (Items Number 3 Through 7) Since Last Report, Give Reason:

9.

Power Level to Which Restricted, IfAny (Net MWe:

10. Reason For Restrictions, IfAn:

This Month Yr.-to-Date Cumulative"

11. Hours in Reported Period
12. Number of hours Reactor Was Critical
13. Reactor Reserve Shutdown Hours
14. Hours Generator On-line
15. Unit Reserve Shutdown Hours
16. Gross Thermal Energy Generated (MWH)
17. Gross Electrical Energy Generated (MWH)
18. Net Electrical Energy Generated (MWH)
19. Unit Service Factor (%)
20. Unit AvailabilityFactor (%)
21. Unit Capacity Factor (using MDC Net) (%)
22. Unit Capacity Factor (using DER Net) (%)
23. Unit Forced Outage Rate (%)

744.0 744.0 0.0 744.0 0.0 1096191.0 373104.0 354741.0 100.0 100.0 101.4 101.4 0.0 744.0 744.0 0.0 744.0 0.0 1096191.0 373104.0 354741.0 100.0 100.0 101.4 101.4 0.0 229512.0 184411.1 1687.6

'81492.7 8.5

'57959499.0 85435604.0 81102553.0 79.1 79.1 76.3 76.3 5.5

24. Shutdowns Scheduled Over Next 6Months(Type, Dateand Duration of Each):

Refuelin and Maintenance Start 4/01196 Duration 62 da

25. IfShutdown At End of Report Period, Estimate Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forcast Achieved INITIALCRITICALITY INITIALELECTRICITY COMMERCIALOPERATION

'UMULATIVETOTALCOMMENCINGJANUARY1, 1975 CUMULATIVETOTALCOMMENCINGNOVEMBER8, 1969

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO: 50-244 UNIT: R.E.

Ginna Nuclear Power Plant DATE: Februa 7

1996 COMPLETED BY:

John Walden TELEPHONE:

716 771-3588 MONTH Januar 1996 DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 477 17.

477 2.

476 18.

477 3.

476 19.

477 4.

476 20.

477 5.

476 21.

477 6.

476 22.

477 7.

476 23.

477 8.

476 24.

477 9.

476 25.

477 10.

476 26.

476 476 27.

477 12.

476 28.

476 13.

476 29.

476 14.

476 30

~

476 15.

476 31.

476 16.

476 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in reporting month.

Compute to the nearest whole megawatt.

REPORT MONTH J>nu><V, 1996 DO(:KET NO.

~0 244 R E GINNA NUCLEAR POWER PLA UNIT SHUTDOWN AND POWER REDUCTIONS DA1 I F r

(:OhlPLI'.1'I'.D BY ohn V. Walden 1I:LI:PHON

- (716) 771-3588 Ho.

Date 0

I-0 0

~

0 O~

CV c0 Vl0O h

08 0 c u0 ot e own c 0O L'icensee Event Report t Em

~ 0 vl 00 EA cOIll c00 D

E 0

V Cause fh Corrective Action to Prevent Recurrence 1

F:

Forced S:

Scheduled Reason:

A-Equipment Failure (Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & License Examination F-Administrative G-Operational Error (Explain)

H-Other (Explain) 3 hlethod:

14tanual 2-hlanual Scram.

3-Automatic Scratn.

4-Other (Explain)

Fxhibit G - Instructions for Preparation of Data Entry Sheets for Liccnscc Event Rcport (LER) File (NURFG-01 Cil )

Exhibit I - Same Source

NMGGRTIVE

SUMMARY

OP OPERATING EXPERIENCE DOCKET NO: 50-244 UNIT: R.E.

Ginna Nuclear Power Plant DATE: F b ua 7

1996 COMPLETED BY:

John Walden TELEPHONE:

716 71-3588 MONTH Januar 1996 Average power for the month was 97%.