UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 June 21, 1995 Dr. Robert C. Mecredy Vice President, Nuclear Operations Rochester Gas and Electric Corporation 89 East Avenue Rochester, NY 14649 R.

E.

GINNA NUCLEAR POWER PLANT INSERVICE TESTING (IST)

PROGRAM FOR PUMPS AND VALVES (1990-1999 THIRD 10-YEAR INTERVAL) RELIEF REQUEST NOS.

VR-31 AND VR-32 (TAC NO. M89336)

Dear Dr. Mecredy:

SUBJECT:

The NRC staff has reviewed information provided by you in your letter dated April 15, 1994, related to the above subject relief requests for the R.

E. Ginna Nuclear Power Plant IST Program for pumps and valves.

Revision 2 of the R.

E. Ginna Nuclear Power Plant IST Program for pumps and valves was submitted in your letter of April 15, 1994.

Revision 2

incorporates all of the actions taken to address IST Program anomalies identified in the NRC's safety evaluations (SEs) dated April 15,

1991, and October 20, 1992, with NRC review completed in an SE issued November 4, 1993.

Additionally, Revision 2 included two new relief requests involving leakage testing of containment isolation valves added to the IST Program, which are now evaluated.

The IST program was developed to the 1986 Edition of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code).

Relief Request No. VR-32 and its alternative is granted pursuant to 10 CFR 50.55a(f)(6)(i) based on the impracticality of the design of the piping configuration and the burden of modifying the design if the ASME Code requirements were imposed, provided you perform an evaluation to determine if the measured leakage rate or the acceptance criteria must be adjusted because of the remaining water in the piping.

The evaluation of this relief request, however, is not applicable to the testing requirements for local leak rate testing of this valve pursuant to 10 CFR Part 50, Appendix J.

If you Relief Request No.

VR-31 in essence is a request to use a later portion of the ASHE Code and is granted pursuant to the provisions of 10 CFR 50.55a(f)(4)(iv) provided the requirements in paragraph 4.2.2.3 of Part 10 are included in the implementation of the alternative as discussed in the enclosed SE.

The rules in OH-10 for leak testing valve combinations may not be consistent with the requirements in 10 CFR Part 50, Appendix J; therefore, you should determine if the requirements of Appendix J are met, and if not, take appropriate actions.

The approval pursuant to 10 CFR 50.55a(f)(4)(iv) does not constitute approval of an exemption to Appendix J.

9507i20342, 95062i PDR ADQCK 05000244 P

PDR

~I; PII E gCgHR I;SPY -Pi

R. Hecredy June 21, 1995 determine that an exemption to Appendix J is needed and has not been requested, actions should be taken as appropriate.

The enclosed SE provides the results of the review and TAG No. H89336 is considered complete.

Sincerely, Docket No. 50-244

Enclosure:

Safety Evaluation cc w/encl:

See next page Ledyard B. Harsh, Director Project Directorate I-I Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Dr. Robert C. Hecredy R.E. Ginna Nuclear Power Plant CC:

Thomas A. Moslak, Senior Resident Inspector R.E. Ginna Plant U.S. Nuclear Regulatory Commission 1503 Lake Road

Ontario, NY 14519 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. William Valentino, President New York State
Energy, Research, and Development Authority 2 Rockefeller Plaza
Albany, NY 12223 Charlie Donaldson, Esq.

Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Nicholas S.

Reynolds Winston 5 Strawn 1400 L St.

N.W.

Washington, DC 20005-3502 Ms. Thelma Wideman

Director, Wayne County Emergency Hanagement Office Wayne County Emergency Operations Center 7336 Route 31
Lyons, NY 14489 Hs. Mary Louise Meisenzahl Administrator, Monroe County Office of Emergency Preparedness ill West Fall Road, Room ll Rochester, NY 14620