RIORrWY Z-REOOI,RT Nfm@5ÃMAIIIEINEIHEIIEE1!ITZON+ETEMI RIDE)

ACCESSION NBR:9412290302 DOC.DATE: 94/12/21 NOTARIZED: NO DOCKET FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G'5000244 AUTH.NAME,'UTHOR AFFILIATION MECREDY,R.C.

Rochester Gas 6 Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION;,'OHNSON,A.R.

Document Control Branch (Document Control Desk)

SUBJECT:

Requests relief from provision of ASME Code,Section XI requirements for interval hydro/tatic testing of Class 3

components.

DISTRIBUTION CODE:

A047D COPIES RECEIVED LTR ENCL SIZE:

TITLE: OR Submittal: Inservice/Testing/Relief rom ASM Code GL-89-04 P

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 0

RECIPIENT ID CODE/NAME PDl-3 LA JOHNSON,A INTERNAL: AEOD/SPD/RAB NRR/DE/EMCB NUDOCS-ABSTRACT RES/DSIR/EIB EXTERNAL LITCO BROWN I B NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD1-3 PD ELLEMENZE 01 NRR/DE/EMEB OGC/HDS3 LITCO RANSOME,C NRC PDR COPIES LTTR ENCL 1

1,,

1 1

1 1

1 0

1 1

1 1

D 0

C U

N NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE '5ASTE! CONTACTTI.IE DOCUMENTCOYTROL DESK, ROOM PI-37 (EXT. SN-20S3 ) TO ELIMIYATEYOUR YAMEFROM DISTRIBI,'TIONLISTS FOR DOCUMEYTS YOU DON"I'EED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 14 ENCL 13

V 4iVD ROCHESTER GASANDEIECTRIC CORPORATION ~ 89 EASTAVENUE, ROCHESTER, N. Y Idhf94001 AREA CODE716 54'-2700 ROBERT C. MECREDY Vice President Nvcieor Operations December 21, 1994 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

, Allen R. Johnson Project Directorate I-3 Washington, D.C.

20555

Subject:

Ginna Nuclear Plant Inservice Program Quality Assurance Manual, Appendix B

ASME Section XI Required Examination Relief Request 28 R.E.

Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Johnson:

The purpose of this letter is to request relief from the provision of the ASME Code,Section XI requirements for interval hydrostatic testing of Class 3 components.

This relief request is made in accordance with the provisions of 10 CFR 50.55(a)(3)(i).

Regulatory Guide 1.147 approved Code Case N-498, "Alternative Rules for 10-year System Hydrostatic Pressure Testing for Class 1 and 2.

The ASME Code Committee has recently passed a revision to N-498 incorporating these alternatives for Class 3 requirements.

This

revision, Case N-498-1, was ballotted positively by the NRC representative.

RGGE requests that we be allowed to incorporate this revised Code Case into our ISI program.

We believe that the alternative testing presented in the Code Case provides the acceptable level of quality to ensure that safety is maintained.

Ver ruly yours, Robert C.

Mec edy REJ/357 xc:

Mr. Allen R. Johnson (Mail Stop 14D1)

Project Directorate I-3 Washington, D.C.

20555 U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Ginna Senior Resident, Inspector 9412290302 94i221 t

PDR'rr'ADOCK 05000244 P 'i PDR

~g-t.

4 P

RELIEF REQUEST N0.,28 I.

Components for Which Relief is Requested:

Class 3 piping systems within scope of Section XI, by Tables IWD-2500-1, Categories DA, DB and DC.

II.

ASME Requirement from Which Relief is Requested:

Relief is requested from the requirements from the hydrostatic pressure

test, IWD-5223, specified in Tables IWD-2500-1, Examination Categories DA, DB, and DC of the 1986 Edition, no addenda.

Table IWD-2500-1, Categories D-A, D-B, and DC requires two inservice (IWD-5221) or functional tests (IWD-5222) and a

hydrostatic test (IWD-5223) per inspection interval.

III. Basis Currently Code Case N-498 is approved for use by Regulatory Guide 1.147.

Case N-498 only covered Class 1

and Class 2

systems.

Recently the ASME Code Committees have approved a

revision to Case N-498 (now N-498-1), which incorporates these requirements for Class 3 systems.

The alternate requirements for Class 3 systems provide an adequate level of safety and can be met under the current established pressure testing program.

IV.

Proposed Alternate Method:

Implement ASME, Boiler

& Pressure Vessel Code Case N-498-1, "Alternative Rules for 10-year System Hydrostatic Pressure Testing for Class 1,2,. and 3 Systems"

g d