Dr., Robert C. Mecredy~

, Vice President, Nucle>> Production Rochester Gas and Electric Corporation 85 East Avenue Ro'chester, NY 14649 Oct-~er 27, 1994

SUBJECT:

R.

E.

GINNA NUCLEAR POWER STATION - EXTENSION OF RELIEF REQUEST NO.

25 (TAC NO.

M90481)'ear Dr. Mecredy:

In your letter dated September 30,

1994, you requested an extension of Relief Request (RR) 25 through the 1995 refueling outage.

The U.S. Nuclear Regulatory Commission, in a letter dated April 11, 1994, granted relief for the 1994 refueling outage from the provisions of the American Society of Mechanical Engineers Boile} and Pressure Vessel Code (ASME Code),

Section XI, requirements for hydrostatic testing for welded repair or replacement activities associated with the service water system (RR 25).

The NRC staff has reviewed the subject request for relief and has concluded in the enclosed Safety Evaluation that the proposed extension of the alternatives contained in RR 25 will provide an acceptable level of quality and safety if, as you proposed, an additional surface examination is performed on the root pass of the weld.

Therefore, pursuant to paragraph 50.55a(a)(3)(i) of Title 10 of the Code of Federal Regulations (10 CFR 50.55a(a)(3)(i)),

the proposed extension for the alternatives contained in RR 25 is authorized to support welded repair or replacement activities for service water system components through the 1995 refueling outage.

Sincerely, Docket No. 50-244

, Original signed by Walter R. Butler, Director Project Directorate I-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/encl:

See next page DOCUMENT NAME:

A:tI,M90481.GI

  • See previous concurrence To receive a copy of this document, indicate in tha botu "C i Copy without attachment/enciosure "E" s Copy with attachment/enciosure "N

~ No copy OFFICE PD I-3'A PDI-3: INT PDI-3: PM

  • NRR:DE
  • GC PDI-3: D NAME 4'Little SMalik AJohnson JStrosnider MYoun WButler DATE (a

94 94 10 17 94 10 25/94 lo 94 GFFil4fAL'~RECORD:::::::CQPY t

\\J 94ii020094 94i027 PDR ADOCK 05000244 P,PDR NIIIC RLlE CH'EIR CIIII'V

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON) D.C. 20555-0001

October 27, 1994 Dr. Robert C. Hecredy Vice President, Nuclear Production Rochester Gas and Electric Corporation 89 East Avenue Rochester, NY 14649

SUBJECT:

R.

E.

GINNA NUCLEAR POWER STATION EXTENSION OF RELIEF RE(VEST NO.

25 (TAC NO. H90481)

Dear Dr. Hecredy:

In your letter dated September 30, 1994, you requested an extension of Relief Request (RR) 25 through the 1995 refueling outage.

The U.S. Nuclear Regulatory Commission, in a letter dated April ll, 1994, granted relief for the 1994 refueling outage from the provisions of the American Society of Hechanical Engineers Boiler and Pressure Vessel Code (ASHE Code),

Section XI, requirements for hydrostatic testing for welded repair or replacement activities associated with the service water system (RR 25).

The NRC staff has reviewed the subject request for relief and has concluded in the enclosed Safety Evaluation that the proposed extension of the alternatives contained in RR 25 will provide an acceptable level of quality and safety if, as you proposed, an additional surface examination is performed on the root pass of the weld.

Therefore, pursuant to paragraph 50.55a(a)(3)(.i) of Title 10 of the Code of Federal Regulations (10 CFR 50.55a(a)(3)(i)),

the proposed extension for the alternatives contained in RR 25 is authorized to support welded repair or replacement activities for service water system components through the 1995 refueling outage.

Sincerely, ZJ Walter R. Butler, Director Project Directorate I-3 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation Docket No. 50-244

Enclosure:

Safety Evaluation cc w/encl:

See next page

Dr. Robert C. Mecredy R.E.

Ginna Nuclear Power Plant CC:

Thomas A. Hoslak, Senior Resident Inspector R.E.

Ginna Plant U.S. Nuclear Regulatory Commission 1503 Lake Road

Ontario, NY 14519 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Hs.

Donna Ross Division of Policy Analysis 8 Planning New York State Energy Office Agency Building 2 Empire State Plaza

Albany, NY 12223 Charlie Donaldson, Esq.

Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Nicholas S.

Reynolds Winston 8 Strawn 1400 L St.

N.W.

Washington, DC 20005-3502 Hs. Thelma Wideman

Director, Wayne County Emergency Management Office Wayne County Emergency Operations Center 7370 Route 31
Lyons, NY 14489 Hs.

Mary Louise Heisenzahl Administrator, Monroe County Office of Emergency Preparedness ill West Fall Road, Room 11 Rochester, NY 14620

DISTRIBUTION:

Docket File PUBLIC PDI-3 Reading W. Russell/F.

Miraglia R.

Zimmerman R. Spessard, D/DRIL J.

Lieberman, D/OE S.

Varga J. Zwolinski W. Butler A. Johnson S. Malik OGC E. Jordan, D/AEOD G. Hill (2 cys)

ACRS (4)

OPA OC/LFDCB W. Dean, EDO J. Linville, RI K. Battige T. McLellan J. Strosnider