F'H.IC)H.I JL V I CCELERATED RIDS PROCESSING)

~ 4 REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9407200133 DOC.DATE: 94/07/12 NOTARIZED: NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.

Rochester Gas

& Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION JOHNSON,A.R.

Document Control Branch (Document Control Desk)

DOCKET 05000244 P

SUBJECT:

Forwards SER addressing best way to assure structural integrity of containment, is through well planned tendon I

surveillance program.

DISTRIBUTION CODE:

A028D COPIES RECEIVED:LTRj ENCL 0 SIZE:

0 R

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 I

RECIPIENT ID CODE/NAME PD1-3 PD INTERNAL: NRR/DE/EMCB NRR/DRPE/PDI-1 NUDOCS-ABSTRACT OGC/HDS3 RES/DE/MEB COPIES LTTR ENCL RECIPIENT ID CODE/NAME JOHNSON,A NRR/DORS/OGCB NRR/DRPW OC/M DCB E&+I 01 COPIES LTTR ENCL EXTERNAL: NRC PDR 1

~

&' o

) 'f 5/ g, g. > f NSIC 1

1 D

C U

N NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACTTHE DOCUMENT CONTROL'ESK, ROOM PI-37 (EXT. 504-2083 ) TO ELIMINATEYOUR NAMEFROM DISTRIBUTIONLISTS I'OR DOCUMENTS YOU DON'T NEEDI TOTAL NUMBER OF COPIES REQUIRED'TTR 15 ENCL

Aqn ROCHESTER GASANDE1ECTR1C CORPORAT1ON

~ 89 FASTAVENUE, ROCHESTER, N. Y 1d6494C61 ROBERT t MECREDY Vice President t;irma Nuclear Production ARFA CODE716 546-2700 July 12, 1994 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Allen R.'ohnson Project Directorate I-3 Washington, D.C.

20555

Subject:

Ginna Containment Structural Integrity R.

E. Ginna Nuclear Power Plant

Dear Mr. Johnson:

The NRC has transmitted to RGGE, via reference 1, their Safety Evaluation Report (SER) addressing the Containment Structural Integrity.

The NRC advised in the SER that the best way to assure the structural integrity of the containment is through a well-planned tendon surveillance program.

RGGE does have in place a tendon surveillance

program, which is consistent with Regulatory Guide 1.35.

That test is scheduled to be done in the summer of 1995 and will be tracked with Engineering Work Request (EWR) f10180.

The scope of the program consists of the following:

r Visual examination of the casing filler grease.

Analytical testing of the casing filler grease.

n Inspection of the anchor as'semblies for deleterious conditions such as corrosion,

cracks, broken wires, or missing buttonheads.

Measuring shim dimensions and anchor head bushing projection to determine liftoff elongation.

Measuring Lift off loads.

Application of additional 64 overstress and measuring corresponding tendon elongation.

Qa'k ~

9407200133 940712 PDR ADOCK 05000244 P

PDR

>p 1

l l

t 0

f

Resealing tendon cans and regreasing anchor assembly.

Removal and visual inspection of one unstressed sacrificial tendon wire.

Tensile testing of tendon specimens.

Evaluation of test and inspection results to assess the general condition of the post-tensioning system and evaluate time dependent factors such as prestress losses and corrosion.

RG&E is planning on replacing Ginna's steam generators in 1996 by removing them through openings cut in the containment building dome.

This project is being tracked under EWR 10034.

After reconstruction of the

dome, a structural integrity test at 115 percent of design pressure will be conducted.

Local measurements of displacement and stress will be performed in the vicinity of the reconstructed area.

Measurements in the cylindrical portion of the containment are also anticipated.

The Ginna tendon surveillance program and the planned structural integrity of the containment building meet the request of reference 1 and should resolve the containment integrity issues.

Very truly yours, Robert C. Mecr dy LAS/388

References 1.

Letter dated May 27, 1994 from NRC (Johnson) to RG&E (Mecredy)

Subject:

"Ginna Containment Structural Integrity Technical Report 500167-7, "Radial Displacement and Rebar Strain Measurement for EWR 5181,"

May 17, 1993 (TAC NO M80494).