Notes Minor Changes to SER to Ensure Clear Correlation Between SER & New TSs Approved in Amend 57 to License DPR-18
ML17263A525
Person / Time
Site: Ginna 
Issue date: 01/19/1994
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To: Andrea Johnson
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
References
TAC-M85326, NUDOCS 9402010101
Download: ML17263A525 (4)


Text

ACCELERATED DI TRIBUTION DEMONS TION SYSTEM

~5

.REGULATORY XNFORMATXON DXSTRIBUTION 'SYSTEM (RIDS)

I2

~

ACCESSION NBR:9402010101 DOC.DATE: 94/01/19 NOTARIZED:'NO DOCKET FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

05000244 AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.

Rochester Gas 6 Electric Corp.

RECIP.NAME RECIPIENT AFFILIATXON JOHNSON,A.R.

Project Directorate I-3

SUBJECT:

Notes minor changes to SER to ensure clear correlation between SER 6 new TSs approved in Amend 57 to License DPR-18.

DISTRIBUTION CODE:

A001D COPIES RECEIVED:LTR ENCL SIZE:

TXTLE: OR Submittal:

General Distribution NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 RECIPIENT ID CODE/NAME PDl-3 LA JOHNSON,A INTERNAL: NRR/DE/EELB NRR/DRCH/HICB NRR/DSSA/SPLB NUDOCS-ABSTRACT OGC/HDS1 EXTERNAL: NRC PDR COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD1-3 PD NRR/DORS/OTS B NRR/DRPW NRR/DSSA/SRXB OC ~ED.CB EG ILE 01 NSIC COPXES LTTR ENCL A

D D

S R

NOTE TO ALL"RIDS" RECIPIENTS:

D S

/

A D

D PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 16 ENCL

'zez jgrziriritvzz aND SZiijgjII //iiSSSSZI utzztll/IE iizzzrnru ROCHESTER GAS AND ELECTRIC CORPORATION o

89 EAST AVENUE, ROCHESTER N.Y. 14649-0001 ROBERTC MECREDY Vice Prerldent Cinna Nuciear Production January 19, 1994 TELEPHONE AREACODE 71B 546 2700 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Allen R. Johnson Project Directorate I-3 Washington, D.C.

20555

Subject:

Clarification to the SER for Amendment No.

57 to Facility Operating License No.

DPR-18 (TAC No. M85326)

R.E.

Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Johnson:

Amendment No.

57 to the Facility Operating License was approved by NRC letter and SER dated December 7,

1993.

We believe that some minor changes to the SER are warranted to ensure clear correlation between the SER and the new Technical Specifications.

The following refer to the SER dated December 7,

1993:

Section 2.1, page 3, 1st paragraph, This paragraph should refer to the RWST replacing the BASTs as a

source of shutdown

boration, not safety injection coolant.

Furthermore, RGGE's calculations have indicated that the negative reactivity rate addition requirement can be met with a

concentration of 2000 ppm at the minimum charging flowrate of 15 gpm, not 60 gpm.

Section 2.3, page 4, paragraph TS 3.2.2 and 3.2.3 We believe it would clarify the paragraph if the SER included the phrase "...from the RWST and/or the BASTs." at the end of the first sentence.

This would clarify, consistent with the Basis section of Section 3.2 to the Technical Specifications, that either the RWST or the BASTs are acceptable sources of CVCS boration.

Very truly yours, Robert C.