LER 93-003-00:on 930328,discovered Failures of Safeguard Svc Water Sys During Planned Maint.Caused by Design & Operating Environ.Replaced Affected Valves W/Qualified Spares.W/ 930720 Ltr
ML17263A330
Person / Time
Site: Ginna 
Issue date: 07/20/1993
From: Backus W
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17263A330 (18)
Forwards LER 93-003-00 Re Discovered Failures of Safeguard Svc Water Sys Valves During Planned Maintenance
ML17263A327
Person / Time
Site: Ginna 
Issue date: 07/20/1993
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17263A327 (4)