ML17263A294
| ML17263A294 | |
| Person / Time | |
|---|---|
| Site: | Ginna |
| Issue date: | 05/17/1993 |
| From: | Joyner J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Mecredy R ROCHESTER GAS & ELECTRIC CORP. |
| Shared Package | |
| ML17263A295 | List: |
| References | |
| NUDOCS 9305250042 | |
| Download: ML17263A294 (5) | |
See also: IR 05000244/1993007
Text
~
FORD I
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCEBBTON NBR:9305250042
DOC.DATE: 93/05/17
NOTARTZED:
NO-
DOCKET
FACIL:50-244 Robert
Emmet Ginna Nuclear Plant, Unit 1,-Roch'ester
G
05000244
UTH.NAME
AUTHOR AFFILIATION
OYNER,J.H.
Region
1 (Post
820201)
RECIP.NAME
RECIPIENT AFFILIATION
MECREDY,R.C.
Rochester
Gas
6 Electric Corp.
R
SUBJECT:
Forwards insp rept 50-244/93-07
on 930412-16.No violations
noted.
I
i
DISTRIBUTION CODE:
IE06D
COPIES
RECEIVED:LTR
ENCL
SIZE:
TITLE: Environ
a Radiological
(50 DKT)-Insp Rept/Notice of Violation Respo
s
j
NOTES:License
Exp date in accordance
with 10CFR2,2.'109(9/19/72).
05000244
J
/-
F
RECIPIENT
ID CODE/NAME
PDl-3 LA
JOHNSONiA
INTERNAL: AEOD/ANDERSON,R
NMSS/SGTB
4E4
NRR/DRIL/RPEB10
NUDOCS-ABSTRACT
OGC/HDS1
RGN1
F1LE
Ol
EXTERNAL: EG&G SIMPSONiF
COPIES
LTTR ENCL
1
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
RECIPIENT
ID CODE/NAME
PD1-3
AEOD/DSP
NRR/DREP/PRPBlo
NRR/PMAS/ILRB12
OE DI;
~EG
02
RGN1
DRSS/RPB
RGN4 MURRAY,B
NRC
COPIES
LTTR ENCL
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
0
NOTE TO ALL "RIDS" RECIPIENTS
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.
ROOM P 1-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION
LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
22
ENCL
21
MAY
1 y
~gg3
Docket No.
50-'244
Dr. Robert C. Mecredy
'ice
President,
Ginna Nuclear Production
Rochester
Gas and Electric Corporation
89 East Avenue
Rochester,
New York 14649
Dear Dr. Mecredy:
Subject:
NRC Inspection No. 50-244/93-07
An announced
safety inspection of the radiological controls program
at your facility was
conducted by Messrs. J. Noggle and J. Nick on April 12- 16, 1993 of activities authorized by
License No. DPR-18.
The inspection involved review of areas important to worker health and
safety.
The inspection findings were discussed with members of your staff on April 16, 1993.
This inspection
focused
on program implementation
during outage conditions and related
concerns.
During the inspection, except for a brief period, the containment was inaccessible
due to the
performance ofan integrated leak rate test and limited work was performed in other radiological
work areas.
Therefore, the inspection did not include a representative review of HP coverage
of work in progress nor was there opportunity to ascertain
the adequacy of the air sampling
program.
Instead, records were reviewed, and discussions with licensee personnel were held
to provide a measure of outage HP performance within the limited context of the inspection.
Radiological- postings
and surveys were strong.
Special Work Permits, which specify the
radiological controls for workers, were not always detailed but were generally well written.
There was evidence ofcontinued efforts made in the temporary shielding program with the need
for further improvements
noted.
The air sample
tracking
system
has
been
improved.
Radiological controls for steam generator work were well applied with resulting low exposures,
Within the scope of this inspection no violations were identified. No response to this letter is
required.
9305250042
930527
ADQCK 05000244
8
OFFlClALRECORD COPY
Rochester
Gas and Electric
Corporation
Your cooperation with us is appreciated.
SY lS
~SS3
Sincerely,
Ortglnal Signed Sy:
James H. Joyner
James H. Joyner, Chief
Facilities Radiological Safety
and Safeguards
Branch
Division of Radiation Safety
and Safeguards
Enclosure:
NRC Inspection Report No. 50-244/93-07
cc w/encl:
R. Smith, Senior Vice President, Production and Engineering
Central Records (4 copies)
Director, Energy and Water Division
State of New York, Department of Law
N. Reynolds, Esquire
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
K. Abraham, PAO (2)
NRC Senior Resident Inspector
State of New York, SLO Designee
OFFtClAL RECORD COPY
Rochester
Gas and Electric
Corporation
bcc w/encl:
Region I Docket Room (with concurrences)
bcc w/encl (VIAE-MAIL):
V. McCree, OEDO
W. Butler, NRR
liig)
7 7
7g93
RI:DRSS
J. Nick
5/Q/93
RI:DRSS
J. Noggle
q fP(
- 5/5/93
RI:DRSS
W. Pasciak
5/ 793
RI:DRSS
J. Joyner
5//793
OFFICIALRECORD COPY