UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 24,1993 Docket No. 50-244 Dr. Robert C. Mecredy Vice President, Nuclear Production Rochester Gas and Electric Corporation 89 East Avenue Rochester, New York 14649

Dear Dr. Hecredy:

SUBJECT:

EMERGENCY RESPONSE CAPABILITY CONFORMANCE TO REGULATORY GUIDE 1.97, REVISION 3 (TAC NO. H80439)

The NRC issued a safety evaluation (SE) with an attached Technical Evaluation Report (TER) on December 4,

1990, after having performed a review of your conformance to Regulatory Guide (RG) 1.97, Revision 3.

The SE/TER found your design acceptable with conformance to RG 1.97, except for instrumentation for monitoring neutron flux, containment isolation valve position, residual heat removal (RHR) heat exchanger outlet temperature, accumulator tank level and

pressure, and emergency ventilation damper position.

Two NRC requests for additional information (RAIs), dated March 22,

1991, and July 7,
1992, indicated the need for clarification with regard to Ginna Station's conformance to RG 1.97, Revision 3.

Based on discussions with you we determined that there was a misunderstanding in the interpretation of RG 1.97 and you were requested to submit new information.

This information was submitted by letters dated Hay 6 and 16,

1991, June 17,
1991, March 13,
1992, Hay 8,
1992, and October 14, 1992.

Additional information was also submitted in an NRC meeting with you on September 16, 1992, at NRC Headquarters.

The meeting included additional clarifications with regard to your conformance to RG 1.97, Revision 3.

Commitments and conclusions were published in an NRC meeting summary dated November 24, 1992.

Enclosure 1 transmits to you a supplemental safety evaluation (SSE) with a TER (EGG-RTAP-10240) by Idaho National Engineering Laboratory (INEL) (Attachment 1).

We have reviewed the evaluation performed by INEL contained in the TER and concur with its bases and findings.

You conform to RG 1.97 guidance, or have provided an acceptable justification for deviations from RG 1.97

guidance, except for instrumentation associated with post-accident neutron flux monitoring.

Post-accident neutron flux monitoring is not addressed in this SE/TER, but will be addressed in a forthcoming separate SSE.

9303030217 930224

'DR ADOCK.05000244 P

PDR f5 a/[

lC GBQQIA

Dr. Robert C. Mecredy February 24, 1993 Enclosure 2 provides a list of references.

Sincerely,

Enclosures:

1.

NRR SSE w/attached INEL TER 2.

List of References

/s/

Allen R. Johnson, Project Manager Project Directorate I-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc w/enclosures:

See next page DISTRIBUTION w enclosure:

..Docket-Fi-1 e 244 NRC 8 Local PDRs PDI-3 Reading SVarga JCalvo JWermiel EMarinos BMarcus WButler AJohnson TClark OGC ACRS(10)

JLinville, RI DISTRIBUTION w o enclosure:

TMurley FMiraglia JPartlow GLainas AHansen JHannon

AUdy, INEL VMcCree EJordan
WLazarus, RI
JDurr, RI
WHodges, RI
RPaolino, RI OFF!CE NAME LA:PDI-3 TClar PM: PDI-3 AJohnson:mw Bc 5FA-JW el D:PDI-3 WButler DATE 93 5 93 2

23 93 S

93 OFFICIAL REC R

COPY FILENAME: A:iGIM80439. LTR

Dr. Robert C. Mecredy February 24, 1993 Enclosure 2 provides a list of references.

Sincerely,

Enclosures:

1.

NRR SSE w/attached INEL TER 2.

List of References Al n R. Johnson, Project Manager Proje 'e I-3 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation cc w/enclosures:

See next page

Dr. Robert C. Hecredy R.E. Ginna Nuclear Power Plant CC:

Thomas A. Hoslak, Senior Resident Inspector R.E.

Ginna Plant U.S. Nuclear Regulatory Commission 1503 Lake Road

Ontario, New York 14519 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Hs.

Donna Ross Division of Policy Analysis 8 Planning New York State Energy Office Agency Building 2 Empire State Plaza

Albany, New York 12223 Charlie Donaldson, Esq.

Assistant Attorney General New York Department of Law 120 Broadway New York, New York 10271 Nicholas S.

Reynolds Winston E Strawn 1400 L St.

N.W.

Washington, DC 20005-3502 Ms. Thelma Wideman

Director, Wayne County Emergency Management Office Wayne County Emergency Operations Center 7370 Route 31
Lyons, New York 14489 Hs. Mary Louise Heisenzahl Administrator, Monroe County Office of Emergency Preparedness 111 West Fall Road, Room 11 Rochester, New York 14620