, ACCEI ERAT~ DOCVMENTDIST VTION SYSTEM REGULAT~ INFORMATION DISTRIBUTION STEM (RIDS)
ACCESSION NBR:9302250216 DOC.DATE: 93/02/12 NOTARIZED:
NO DOCKET N
I*
FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G
050 0244 AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.
Rochester Gas 6 Electric Corp.
RECIP.NAME
'ECIPIENT AFFILIATION JOHNSON,A.
'Project Directorate I-3
SUBJECT:
Forwards<Rev 7 to Emergency Operating Procedure AP-RCP.l, "RCP Seal Malfunction."
DISTRIBUTION CODE:
A003D COPIES RECEIVED:LTR / ENCL /
SIZE'ITLE:
OR/Licensing Submittal:
Suppl 1 to NUREG-0737(Generic Ltr 82-33)
NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
05000244 RECIPIENT ID CODE/NAME PDl+3 LA JOHNSON,A INTERNAL; R~RG+QHFB11 REG FILE 01 EXTERNAL: NRC PDR COPIES LTTR ENCL 1
1 2
2 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD1-3 PD OC/LFMB RES/DSIR/EIB NSIC COPIES LTTR ENCL 1
1 1
1
)'Ii QS +g$ 7g$ /TTpP
",(Pr NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTEI CONTACI'HE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 10 ENCL 9
0l E
s
,I r,
r,
~
4
'W k>
II
~
C
~
~~i
/ ///t uw
//ilerI ES f/
Z/////////I
/ //I////
////////////
ROCHESTER GAS AND ELECTRIC CORPORATION ROBERTC MECREDY Vice President Cinna Nuclear Production rs re L ~irowri 4
89 EAST AVENUE, ROCHESTER N.Y. 14649-0001 TELEPHONE AREACOOE 71B 546 2700 February 12, 1993 U.S. Nuclear Regulatory Commission Document Control Desk Attn:
Mr. Allen Johnson Project Directorate l-3 Washington, D.C. 20555
Subject:
Emergency Operating Procedures R. E. Ginna Nuclear Power Plant Docket No. 50-244 Gentlemen:
As requested, enclosed are Ginna Station Emergency Operating Procedures.
Very tr
- yours, Robert C. Mecredy Enclosures c:
Mr. Lee Bettenhausen, USNRC, Region 1.
Resident Inspector, Ginna Station 9302250216 9302i2 PDR ADOCK 05000244 P
I I
J s (
~ >
/~
ll 1
I'
AP-RCP.1 RCP Seal Malfunction
EOP:
AP-RCP.1 TITLE: ~:
RCP SEAL MALFUNCTION REV 6
GE 1 of 6 ROCHESTER GAS AND ELECTRIC COR ORATION GINNA STATION CONTROLLED COPY NUMBER rQ ~
TECHNICAL RE IEW PORC REVI DAT
/
Q.
LANT SUP ENDENT EFFECTIVE DATE QA NON-QA REVIEWED BY:
CATEGORY 1.0 Tl'yI> I DATE
0 I
EOP:
AP-RCP.1 TITLE:
RCP SEAL MALFUNCTION REV:
6 PAGE 2 of 6 A.
PURPOSE This procedure provides the instructions necessary to diagnose and to respond to a reactor coolant pump seal malfunction.
B.
ENTRY CONDITIONS/SYMPTOMS 1.
ENTRY CONDITIONS This procedure is entered from:
a.
ECA-0.1, LOSS OF ALL AC POWER RECOVERY WITHOUT SI REQUIRED, Step 11, or b
ES 1
1 g SI TERMINATION Step 12 g or c ~
ES 1 ~ 2 g POST LOCA COOLDOWN AND DEPRES SURIZATION g Step 20, or d.
ECA-2.1, UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS, Step 24, or e.
E-3, STEAM GENERATOR TUBE RUPTURE, Step 34, or f.
ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT-SUBCOOLED RECOVERY DESIRED, Step 28, or g
ECA 3 ~ 2 ~
SGTR WITH LOSS OF REACTOR COOLANT SATURATEDg RECOVERY DESIRED, Step 21, or h
ECA 3 ~ 3 g SGTR WITHOUT PRESSURI ZER PRESSURE CONTROL/
Step 18, or i
FR I ~ 1 g
RESPONSE
TO HIGH PRESSURI ZER LEVEL/
Step 5.
~
2.
SYMPTOMS -: The symptoms of RCP SEAL MALFUNCTION are; a.
RCP 1A/(1B) No.l SEAL HI-LO FLOW 5.5 GPM 0.25 ALARM B-17/(18), or b.
RCP 1A/(1B)
LABYR SEAL LO DIFF PRESS 15" H20 ALARM, B-9/(10), or c.
RCP lA/(lB) STANDPIPE HI LEVEL +
1 FT alarm, B-3/ (4), or Continued on next page
EOP:
AP-RCP.1 TiTLE:
RCP SEAL MALFUNCTION REV 6
PAGE 3 of 6 2.
SYMPTOMS (cont) d.
RCP 1A/(1B)
STANDPIPE LO LEVEL -4 FT alarm, B-ll/(12), or e.
RCP 1A/(1B) No.
1 SEAL LO DIFF PRESS 220 PSID alarm, B-25/ (26), or f.
RCP 1A/(1B) No.
1 SEAL OUT HI TEMP 200'F alarm, B-1/ (2)
~
EOP:
AP-RCP.1 TITLE: 0 RCP SEAL MALFUNCTION REV:
6 PAGE 4 of 6
STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED CAUTION IF, AT ANY TIME DURING THIS PROCEDURE, A REACTOR TRIP OR SI OCCURS, E-O, REACTOR TRIP OR SAFETY INJECTION, SHOULD BE PERFORMED.
NOTE:
Step 1 is an IMMEDIATE ACTION step.
1 Check RCP No.
1 Seal
~
~
~
Indication:
a.
No.
1 seal leakoff flow - LESS THAN 5.5 GPM
- a. IF No.
1 seal leakoff flow greater than or equal to 5.5
- GPM, THEN close seal disch vlv(s) AOV-270A (A RCP)
-270B (B RCP)
AND perform the following:
o IF Rx at power, THEN:
- 1) Trip the Rx.
- 2) Trip the affected RCP(s).
3)
Go to E-O, REACTOR TRIP or SAFETY INJECTION.
o IF Rx shutdown, THEN:
- 1) Trip the affected RCP(s).
2)
Go to Step 8.
EOP:
AP-RCP.1 TITLE:
RCP SEAL MALFUNCTION REV:
6 PAGE 5 of 6 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 2
Check No.
1 Seal Indication:
o No.
1 seal leakoff flow-GREATER THAN 0.25 GPM IF No.
1 seal outlet temperature greater than 215'F, THEN go to Step 7.
IF No.
1 seal outlet temperature less than 215'F, THEN verify leakage increase from No.
2 seal to the RCDT.
3 Check No.
2 Seal Indications:
a.
RCP standpipe lo level alarms, B-11/(12) - NOT LIT b.
RCP standpipe hi level alarms, B-3/(4) - NOT LIT
- a. IF either RCP standpipe lo level alarm lit, THEN go to Step 4.
- b. IF either RCP standpipe hi level alarm lit, THEN go to Step 6.
4 Check Containment Radiation Monitors:
o R NORMAL o
R NORMAL IF RCP standpipe lo level alarm and CNMT radiation increasing, THEN No.
3 seal leakage increase is probable.
Continue plant operation while closely monitoring RCP seal operation.
5 Check Both RCP Diff Press:
o GREATER THAN - 220 PSID IF Rx at power, THEN:
- a. Trip the Rx.
- b. Trip the affected RCP(s).
c.
Go to E-O, REACTOR TRIP or SAFETY INJECTION IF Rx shutdown, THEN:
- a. Trip the affected RCP(s).
b.
Go to Step 8.
EOP:
AP-RCP.1 RCP SEAL MALFUNCTION REV 6
PAGE 6 of 6 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 6
Check Both RCP Labyr Seal Diff Press:
o GREATER THAN -
15 INCHES OF VATER IF Labry seal D/P is low, THEN ensure CCW flow to the RCP thermal
- barriers, AND
- a. Verify charging in service and check seal infection flow.
- b. Ad)ust HCV-142 if desired.
- c. Direct AO to check seal in]ection filter D/P.
7 Check Both RCP Seal No.
1 Outlet Temperatures:
o LESS THAN - 215'F IF Rx at power, THEN:
- a. Trip the Rx.
- b. Trip the affected RCP(s).
c.
Go to E-O, REACTOR TRIP or SAFETY INJECTION.
IF Rx shutdown, THEN:
- a. Trip the affected RCP(s).
b.
Go to Step 8.
8 Establish MONXTORING OF RCP SEAL INDICATXON (Refer to ATTACHMENT A as necessary)
NOTE:
Refer to 0-9.3, NRC IMMEDIATE NOTIFICATION, for reporting requirements.
9 Complete NOTIFICATION TO HIGHER SUPERVISXON
-END-
EOP:
AP-RCP.1 TITLE:
RCP SEAL MALFUNCTION 0
REV 6
PAGE 1 of 1 ATTACHMENT A REACTOR COOLANT PUMP SEAL TROUBLE SHOOTING TABLE Alarm S
toms Seal.
No.
1 Seal Injection Leak Off-
.Su l Off Loss Of Malfunction No.
1 No.
2 Seal Seal No.
3 Pump Seal Bearin<
1)
No.
1 seal out hi temperature 200'F 2)
Pump radial bearing water tern erature Hi h 200'F X
3)
Labyrinth seal low differential pressure 15 inches H20 X
4)
No.
1 seal low differential ressure 220 sid 5)
No.
1 seal Low flow 0.25 m
X 6)
No.
1 seal high flow 5.5 m
X 7)
Standpipe high level X
8)
Standpipe low level X Most likely malfunction or alarm 0
Possible malfunction