ML17262A958

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-244/92-09 on 920527-0720.Several Design & Analytical Limitations Were Identified Re Long Term Integrity of Repair for Erosion/Corrosion Failure of Preseparator Drain Tank
ML17262A958
Person / Time
Site: Ginna 
Issue date: 08/14/1992
From: Linville J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
Shared Package
ML17262A959 List:
References
NUDOCS 9208250073
Download: ML17262A958 (6)


See also: IR 05000244/1992009

Text

AUG 14 IgZ

Docket No. 50-244

Dr. Robert C. Mecredy

Vice President,

Ginna Nuclear Production

Rochester Gas and Electric Corporation (RG8cE)

89 East Avenue

Rochester, New York 14649

Dear Dr. Mecredy:

Subject:

GINNA INSPECTION 92-09

This letter transmits the May 27 to July 20, 1992 inspection findings of Messrs. T. Moslak

and E. Knutson at the R. E. Ginna Nuclear Power Plant, and of Messrs H. Kaplan and

A. Lohmeier of the NRC Region I staff. At the end of the inspection, the findings were

discussed with Mr. R. Marchionda and other members of your staff.

The inspection was focused on areas relevant to public health and safety, and examined the

control of operations,

maintenance,

and engineering conducted during this period.

The plant

was operated safely during this period, although several design and analytical limitations were

identified regarding the long term integrity of the repair for the erosion/corrosion failure of a

preseparator drain tank.

No response to this letter is required.

Thank you for your cooperation.

Sincerely,

Nil. at:NEo By.

Ja

C. Linville, Chief

Pr

ects Branch No. 3

Division of Reactor Projects

Enclosure:

NRC Region I Inspection R

rt 50-244/92-09

9208250073

920814

PDR

ADOCK 05000244

8

PDR

Dr. Robert C. Mecredy

~

~

cc w/encl:

R. Smith, Senior Vice President, Production and Engineering

Central Records (4 copies)

Director, Power Division

State of New York, Department of Law

N. Reynolds, Esquire

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

K. Abraham, PAO (2 copies)

NRC Resident Inspector

State of New York, SLO Designee

AUG i4 199K

0

~

0FrXCIALRECORD COpY

~

~

Dr. Robert C. Mecredy

~

~

AUG 14 )95?

bcc w/encl:

Region I Docket Room (with concurrences)

(w/cy of IFS Forms)

DRS/EB SALP Coordinator

J. Linville, DRP

W. Lazarus, DRP

T. Moslak, SRI - Gihna (w/cy of IFS Forms)

A. Johnson, PM, NRR

R. Lobel, OEDO

bcc w/Letter and Executive Summary Only:

T. Martin, RA

W. Kane, DRA

C. Hehl, DRP

J. Wiggins, DRP

R. Cooper, DRSS

W. Hodges, DRS

W. Lanning, DRS

C. Anderson, DRS

L. Bettenhausen,

DRS

J. Joyner, DRSS

D. Holody, EO

RI:DRP

RI:DRP

RI D

D

Moslak/meo

7/30/92

g /W/ga.

1 e

OFFICIALRECORD COPY

A:GIN9209.MEO