ACCE ERATED DISTRIBUTION DEMONSTRATION SYSTEM REQULAT XNFORNATION DISTRIBUTION v'STEN (RIDS)

ACCESSION NBR208170111 DOC. DATE'2/08/10 NOTARIZED:

NO FACXL: 50-244 Rohev t Emmet Qinna Nucleav Planti Unit ii Rochestev 9

AUTH. NAME AUTHOR AFFILXATION NECREDYI R. C.

Rochestev Qas h Electv'ic Cov p.

RECIP. NANE REC XP IENT *FFXLIATION JOHNSON> *. R.

Document Control Bv anch (Document Contv'ol Desk)

DOCKET 0 05000244

SUBJECT:

Rev 0 to "GA Manual Qinna Station Xnsevvice Xnsp Program for 1'790-1'7'PV Interval.. "

DISTRIBUTION CODE'047D COPIES RECEIVED: LTR ENCL Q SIZE: 5 ~

TITLE:

OR Submittal:

Xnsev vice Inspection/Testi g/Relief fv om ASNE Code 1

COPIES LTTR ENCL 1

1 NOTES: License Exp date in accov dance eith 10CFR2i 2. 109(9/19/72).

5 RECIPIENT RECIPIENT ID CODE/NAME ID CODE/NAI"IE PD1-3 LA PD1-3 PD JOHNSON> A 05000244 c

INTERNAL: NRR/DET/ECNB 9H NUDOCS-ABSTRACT OQC/HDSi RES NILLNANI9 1

1 NRR/DET/ENEB 7E 1

1 OC/LFNB 0

Oi 1

1 0

1 1

EXTERNAL: E959 BROhlNI B NRC PDR 1

1 EQKc9 RANSONE> C 1

1 NSIC Li NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESk.

ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUNBER OF COPIES REQUIRED:

LTTR ih ENCL 13

t N

//////////

It/I!II I

i////////////

J ROCHESTER GAS AND ELECTRIC CORPORATION o

89 EAST AVENUE, ROCHESTER N.Y. 14649-0001 ROBERT C MECREDY Vice President-Ginna Nudear Production August 10, 1992 TELEPHONE AREACODE 7t B 546 2700 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Allen R. Johnson Project Directorate I-3 Washington, D.C.

20555

Subject:

Submittal of Appendix B to the Quality Assurance Manual Inservice Inspection Program for the 1990 1999 Interval R. E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Johnson:

As requested by your telecon of July 8,

1992, the following sections of Appendix B to the Quality Assurance Manual are submitted for your information:

ATTACHMENT B INTRODUCTION Rev.

0, Jan.

1, 1990, 1 page 2.

ATTACHMENT B Class 1 Non-Exem ted S stem Drawin s, Introduc-

tion, Rev.

0 (1 page) and including the six (6) drawings identified thereon 3.

4.

ATTACHMENT tion, Rev.

identified ATTACHMENT tion, Rev.

identified B

Class 2 Non-Exem ted S stem Drawin s Introduc-0, (1 page) and including the nine (9) drawings thereon B

Class 3 Non-Exem ted S stem Drawin s Introduc-0, (1 page) and including the eight (8) drawings thereon 5..

ATTACHMENT B Exem ted S stem Drawin s Introduction, Rev. 0, (1 page) and including the nineteen (19) drawings identified thereon 6.

ATTACHMENT C Allocation Tables, Rev.

0, effective Jan.

1,

1990, 32 pages 8.

Supplement 2 to Appendix B of the Quality Assurance Manual;

Repair, Replacement and Modification (RR&M) Program, Rev.

0, effective May 30,

1991, 21 pages I (P It is our understanding from vour t scon PDR ADOCK'5000244 l

that the remaznxng part L4r Pd/

~g @Ed ZZ/dI/Me>/D 7.

Supplement.1 to Appendix B of the Quality Assurance Manual; Inservice Inspection Program Plan for 1990 to 1999, Rev.

3, Approved March 19, 1992

of Appendix B to the Quality Assurance Manual were previously received by you.

These consisted of:

9.

Ginna Nuclear Power Station, Inservice Inspection Program for the 1990 1999 Interval, Rev.

1, effective January 1, 1991, 111 pages 10.

Attachment A to Appendix B to the Quality Assurance

Manual, Line List, Rev. 1, effective January 1, 1991, 118 pages.

The format of Appendix B to the Quality Assurance Manual is organized into major sections to facilitate revising of individual sections.

Except for Supplements 1 and 2, as individual sections are revised, it is our intent to forward them in separate sub-mittals for your information.

Supplement 1 to Appendix B represents RG&E's Inservice Inspection Program Plan for implementing the Program requirements.

It was developed for RG&E use and contains the detailed listing of the schedular inspections and examinations to be performed. for the ASME Code required components under the ISI Program.

Supplements 1 and 2 and their revisions are reviewed by the ANII as required and are normally examined by NRC inspection staff during refueling outages.

It would not be our intention to submit the relatively frequent revisions to Supplements 1

and 2,

since they are implementing documents under the ISI Program and are not required entities of the ISI Program for the ASME Code Section XI to be submitted under 10CFR50.55a.

The RG&E ISI Program is defined within the documents listed as items 1-6 and 9

and.

10 above.

We will forward for your information revisions to these as they occur.

Very truly yours, GAHN241 Robert C.

Mec edy xc:

Mr. Allen R. Johnson (Mail Stop 14D1)

Project Directorate I-3 Washington, D.C.

20555 U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Ginna Senior Resident Inspector

0

~A