Text
Docket No. 50-244
Dr. Robert C. Mecredy
Vice President,
Ginna Nuclear Production
Rochester Gas and Electric Corporation
89 East Avenue
Rochester,
New York 14649
Dear Dr. Mecredy:
SUBJECT:
Inservice Inspection Program Inspection at R.E. Ginna Nuclear Power Plant,
(NRC Inspection Report No. 50-244/92-06)
This refers
to the safety inspection
conducted
by Mr. R. A. McBrearty of this office on
April 13-l7, 1992 at the R. E. Ginna Nuclear Power Plant, Ontario, New York of activities
authorized
by NRC License No. DPR-18 and to the discussions of our findings held by
Mr. McBrearty with Mr. R. Marchionda of your staff at the conclusion of the inspection.
The inspection was directed toward the inservice inspection program and the steam generator tube
eddy current examination program.
These inspections are used to determine that programs you
have in place to detect inservice degradation confirm the plant's acceptability for continued safe
operation and satisfy your commitments and regulatory requirements.
Generally, we found your
program implementation satisfactory.
Areas examined during this inspection are described in the
NRC Region I Inspection Report which is enclosed with this letter.
Within these areas,
the
inspection
consisted
of selective
examinations
of procedures
and
representative
records,
interviews, with personnel and observations by the inspector.
Within the scope of this inspection, no violations were observed.
No reply to this letter is required.
Your cooperation with us in this matter is appreciated.
Sincerely,
Clifford J. Anderson, Acting Chief
Engineering Branch
Division of Reactor Safety
Enclosure:
NRC Region I Inspection Report Number 50-244/92-06
~
9205190081
920511
ADQCK 05000244
6
i
r
4
Robert C. Mecredy
cc w/encl:
R. Smith, Senior Vice President, Production and Engineering
Central Records (4 copies)
Director, Power Division
State of New York, Department of Law
N. Reynolds, Esquire
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
K. Abraham, PAO (2) AllInspection Reports
State of New York, SLO Designee
bcc w/encl:
Region I Docket Room (with concurrences)
(w/cy of IFS Forms)
Management Assistant, DRMA (w/o encl)
J. Linville, DRP
W. Lazarus, DRP
T. Moslak, SRI - Ginna (w/cy of IFS Forms)
R. Lobel, OEDO
G. Johnson, NRR
RI:DRS
RI:DRS
Gray
05////92
RI:DRS
Anderson
0 9
05///92
OFFICIAL RECORD COPY
A:GINNA.RB