ACCELERATED DI~OBUTION DEMONSTPTION SYSTEM I ~
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9205070221 DOC.DATE: 92/05/04 NOTARIZED:
NO DOCKET g
FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G
05000244 AUTH.NAME AUTHOR AFFILIATION WIDAY,J.A.
Rochester Gas 6 Electric Corp.
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Interim Part 21 rept re 920313 discovery of potential inaccuracies associated w/using open calibr approach to measure closing stem thrust of MOVs.Program for re-evaluation of previous test results in progress.
DISTRIBUTION CODE:
IE19D COPIES RECEIVED:LTR J ENCL Q SIZE:
TITLE: Part 21 Rept (50 DKT)
NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
05000244 D
RECIPIENT ID CODE/NAME PD1-3 LA JOHNSON,A INTERNAL: AEOD/DSP/ROAB NRR/DRIS/RVIB9D RES/DSIR/EIB RGN2 RGN4 SECY VANDERMEL EXTERNAL: INPO RECORD CTR NSIC SILVER,E COPIES LTTR ENCL 1
0 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD1-3 PD
/
OEA OGCB11 EG F
01 R
RGN3 RGN5 NRC PDR COPIES LTTR ENCL 1
1 2
2 1
1 1
1 1
1 1
1 D
D R
D NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASEE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED'TTR 18 ENCL 17 D
D S
i I
ziznzrm razed
~ 'tijl izzard zz>8F>>eizrz ROCHESTER GAS AND ELECTRIC CORPORATION o Ndd haa< OefAa 89 EAST AVENUE, ROCHESTER, N.K 14649.0001 TE'LEPHONd AREA coDK 7ld 546-2700 May 4, 1992 U.
S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
Subject:
10CFR Part 21 Interim Report R.
E. Ginna Nuclear Power Station Docket No. 50-244 Licensee No.
DPR-18 The revision to 10 CFR Part 21,'Section 21(a) made effective on 10/29/91, requires an 'interim report of any deviation for which an evaluation to determine.reportability impact 'is unable to be completed within 60 days of discovery.
A deviation requiring additional evaluation time is described in Attachment A.
Further correspondence on the item described in Attachment A will not be issued unless the evaluation is not completed as scheduled or the deviation requires reporting per 10 CFR Part 21.
Very Truly Yours, s
h A. Wida Plant Manager Ginna Station attachments:
1 xc:
Region I, U.S.. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Ginna USNRC Senior Resident Inspector 9205070221 920504 PDR
" ADOCK 05000244 8,.
" '.PDR
0 t
h
(
"I 4
I I
ATTACEBCENT A 10 CFR 21 Deviation Evaluation Extension Deviation Discovery Date:
March 13, 1992
==
Description:==
A letter from D. Janacek (MOVATS) to J.
Widay (RG&E), dated February 28, 1992 alerted RG&E to potential inaccuracies associated with using the "Open Calibration" approach to measure the closing stem thrust of MOV's.
The measured thrust could be outside of the accuracies previously published by MOVATS.
This letter was evaluated, and on March 13,
- 1992, RG&E initiated an internal document (PCAQ 92-008) that identified this deviation as
~applicable to RG&E.
A program of re-evaluation of previous test results and performance tests is in progress during the current annual refueling and maintenance outage.
Upon completion of these tests, final evaluations can be performed.
Scheduled Evaluation Completion Date:
June 1, 1992