~gS REGs~i s~G
~o Cy OO IVl 0
>>**+i(
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555 April 21, 1992 Docket No. 50-244 Dr. Rob'ert C. Mecredy, Vice President Ginna Nuclear Production Rochester Gas
& Electric Corporation 89 East Avenue Rochester, New York 14649
Dear Dr. Mecredy:
SUBJECT:
PRESSURIZER SURGE LINE THERMAL STRATIFICATION, BULLETIN 88-11, GINNA NUCLEAR POWER PLANT (TAC NO. M72135)
On December 20,
- 1988, NRC Bulletin 88-11, "Pressurizer Surge Line Thermal Stratification," was issued to all holders of operating licenses or construction permits for pressurized water reactors (PWRs).
The Bulletin requested specific actions to ensure pressurizer surge line integrity with specific consideration of the issue of thermal stratification.
In correspondence dated March 6, 1989 and May 31,
- 1989, RG&E informed the NRC that resolution of the pressurizer surge line thermal stratification issue for Ginna would be accomplished by a combination of Westinghouse Owners Group (WOG) and plant specific programs.
This letter is to inform you that the review of the WOG report (WCAP-12639) has been completed by the NRC staff and can be used for Ginna to satisfy Actions l.c and l.d of'Bulletin 88-11 provided plant specific applicability is demonstrated and additional evaluations not included in the WOG program were performed (Enclosure).
By letters dated February 8,
- 1991, and October 29,
- 1991, RG&E submitted WCAP-12928 and WCAP-12929 plant specific analyses of thermal stratification effects on the Ginna pressurizer surge line.
A staff review of that report concludes that RG&E has verified the applicability of WCAP-12639 and performed the additional analyses necessary to complete items l.c and l.d of V205050287 920421 PDR AOaCV 08000244
'i
'i 8
l
Dr. Robert C. Hecredy April 21, 1992 Bulletin 88-11.
Therefore, TAC No. H72135 associated with the Ginna response to Bulletin 88-11 has been closed.
As stated in the reporting requirements of the Bulletin, the analyses and other documentation associated with your response should be maintained for possible future inspection by the NRC.
Sincerely, original signed by
Enclosure:
As stated cc w/enclosure:
See next page Allen R. Johnson, Project Manager Project Directorate I-3 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation 0FFIGE LA: DI-3 PH: PDI-3 J or er A D'PDI-3 DATE 92 92 8 Zo 92 OFFICIAL RE R
COPY FILENAME: A:iGIH72135. LTR NANE HR s k
AJohnso
~ 92
I N
P J
4
Dr. Robert C. Mecredy Ginna CC:
Thomas A. Hoslak, Senior Resident Inspector R.E.
Ginna Plant U.S. Nuclear Regulatory Commission 1503 Lake Road
- Ontario, New York 14519 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Hs.
Donna Ross Division of Policy Analysis 5 Planning New York State Energy Office Agency Building 2 Empire State Plaza
- Albany, New York 12223 Charlie Donaldson, Esq..
Assistant Attorney General New York Department of Law 120 Broadway New York, New York 10271 Nicholas S.
Reynolds Winston 5 Strawn 1400 L St.
N.W.
Washington, DC 20005-3502 Hs. Thelma Wideman
- Director, Wayne County Emergency Management Office Wayne County Emergency Operations Center 7370 Route 31
- Lyons, New York 14489 Ms.
Susan Per ry Administrator, Monroe County Office of Emergency Preparedness ill West Fall Road Rochester, New York 14620
I
/II
DISTRIBUTION w
Enclosure:
'-:Docket Fi.le No. 50-244 NRC PDR Local PDR DISTRIBUTION w o
Enclosure:
PDI-3 reading S. Varga G. Lainas W. Lazarus, RI H. Rushbrook A. Johnson J.
Calvo W. Hehl, RI J.
Richardson OGC (f/info only)
ACRS (10)
J. Linville, RI H.
Shaw J.
Norberg J.
Shea V. Nerses W. Butler
i.j