Requests Relief from ASME Code,Section XI Re Removal of Relief Valves from Sys During Hydrostatic Test & Hydrostatic Testing of Relief Valves Section Xi,Div I
ML17262A818
Person / Time
Site: Ginna Constellation icon.png
Issue date: 04/14/1992
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To: Andrea Johnson
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
References
NUDOCS 9204230224
Download: ML17262A818 (8)


Text

ACCELERATED DISTRIBUTION DEMONSITWTION SYSTEM e

t REGULATORY XNFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9204230224 DOC.DATE: 92/04/14 NOTARIZED: NO DOCKET FACXL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

05000244 AUTH.NAME AUTHOR AFFILIATXON MECREDY,R.C.

Rochester Gas 6 Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION JOHNSON,A.R.

Project Directorate I-3

SUBJECT:

Requests relief from ASME Code,Section XI re removal of relief valves from sys during hydrostatic test 6 hydrostatic testing of relief valvesSection XX,Div I.

DISTRIBUTION CODE:

A047D COPIES RECEIVED:LTR ENCL 3 SIZE:

TITLE: OR Submittal:

Xnservice Inspection/Testing/Relic from ASME Co e

R D

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72) 05000244 A

RECIPIENT ID CODE/NAME PD1-3 LA JOHNSON,A COPIES LTTR ENCL 1

0 2

2 RECXPIENT XD CODE/NAME PD1-3 PD COPIES LTTR ENCL 1

1 D

INTERNAL: NRR/DET/ECMB 9H NUDOCS-ABSTRACT OGC/HDS1 RES MILLMAN,G EXTERNAL: EGGG BROWN,B NRC PDR 1

1, NRR/DET/EMEB 7E 1

1 QPJS 1

0 REG EIL~ 01 1

1

~SIR/EI 8 1

1 EG&G RANSOME,C 1

1 NSIC 1

1 1

0 1

1 1

1 1

1 1

1

~i(g'7 pgq57 D

NOTE TO ALL"RIDS" RECIPIENTS:

A D

D PLEASE HELP US TO REDUCE WAS'ONTACTTHE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 16 ENCL 13

~,

I II I

//ISIS a no

//////t//It///

/////////////

/

///////I//I I/I/////////

ROCHESTER GAS AND ELECTRIC CORPORATION 4

89 EAST AVENUE, ROCHESTER N.Y. 14649-0001 ROBERT C MECREDY Vice President Cinna Nuclear Production April 14, 1992 TELEPHONE AstEa, cooE Tie 546.2700 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Allen R. Johnson Project Directorate I-3 3Washington, D.C.

20555

Subject:

Quality Assurance Manual, Appendix B Incorporation of ASME Section XI Code Case N-495, Hydrostatic Testing of Relief Valves at

'.E.

Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Johnson:

The purpose of this letter is to notify the NRC that Rochester Gas and Electric requests relief from the ASME Code,Section XI (see, Relief Request No. 17).

We would alternatively use ASME Boiler and Pressure Vessel Code Case N-495 (see Attachment 2) at the R.E.

Ginna Nuclear Power Plant during the 1992 Refueling Outage and the reminder of the current Third Interval Inservice Inspection Program.

This Code Case pertains to alternative rules for the removal of system relief valves during a system hydrostatic test.

It is our understanding that. this Code Case has been incorporated into the draft of the new Regulatory Guide 1.147, "Inservice Inspection Code Case Acceptability ASME Section XI Division 1" which has not yet been issued.

This Case allows the associated piping (pressure boundary) with the relief valve to be removed during a system hydrostatic test.

The relief valve assembly will be tested in accordance with the requirements of a Section XI Subsection IWV test program.

At the completion of the system hydrostatic test, the relief valve and associated.

piping will be reinstalled and inservice leak test performed on the affected mechanical joint(s).

It is requested that upon completion of your review that a reply be provided to Rochester Gas and Electric granting the use of Code Case N-495.

Code Case N-495 will also'be incorporated in the next revision of the Quality Assurance

Manual, Appendix B

Program (Inservice Inspection Program) upon your formal notification.

Ver trul

yours,

((

~Q GJW/221 Uo '3.

9204230224 920414 PDR ADOCK 05000244 P

'DR Robert C. Mecredy

xc: Mr. Allen R. Johnson (Mail Stop 14D1)

Project Directorate I-3 Washington, D.C.

20555 U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Ginna Senior Resident Inspector

~,

4

%E

~"

I VJ

ATTACHMENT 1 REZIEF REQUEST NO.

17 REMOVAL OF REZIEF VALVES FROM A SYSTEM DURING HYDROSTATIC TEST Components from which relief is requested:

The removal of relief valves for Class 2 and 3 systems during the Interval Hydrostatic Test (ten year).

II.

ASME Requirement from which relief is requested:

In accordance with the footnotes of Tables IWC-2500-1 and IDW-2500-1 no pressure boundary component is exempt during the performance of the interval Hydrostatic Test (ten year).

The removal o'f the relief valves would constitute a violation of this requirement.

Leaving the relief valves in place, would require the installation of a gagging device during the hydrostatic pressure test.

From past experience the installation of a gagging device during a pressure test may damage the

valve, even if the valve is designed to be gagged.

III.

Proposed Alternate Method:

Code Case N-495. give alternate rules and exempts relief valves from the interval Hydrostatic Test as part of the test boundary.

The relief valve can be removed and it's connection points sealed for the test.

The alternate rules impose the following requirements:

2.

The functional testing program for the relief valves meets the requirements of ASME Section IX, Subsection IWV.

Upon reinstallation of the relief valve after the pressure test the valve connection points are tested in accordance with IWC-5221 and IWD-5221.

~

4

Attachment 2

Hydrostatic Testing of Relief ValvesSection XI, Division 1 Inquiry:

What alternative rules to those stated in Section XI, Division 1, IWC-5222, and IWD-5223 may be used when a

relief valve is removed. and is not subjected to a system hydrostatic test'?

Reply:

It is the opinion of the Committee

that, as an alternative to the requirements of Section XI, Division 1, IWC-5222, and IWD-5223, a relief valve may be removed and not subjected to a system hydrostatic test when the following requirements are met.

(a)

The relief valve functional testing meets the requirements of Subsection IWV.

(b)

When the relief valve is reinstalled, a

system inservice pressure test is performed.

on the mechanical joint in accordance with IWC-5221 or IWD-5221, as applicable.