March 1992 Docket No. 50-244 Dr. Robert C. Hecredy, Vice President Ginna Nuclear Production Rochester Gas

& Electric Corporation 89 East Avenue Rochester, New York 14649

Dear Dr. Mecredy:

SUBJECT:

CLOSEOUT OF GENERIC LETTER 89-10, "SAFETY-RELATED MOTOR-OPERATED VALVE (HOV) TESTING AND SURVEILLANCE" (TAC NO. M75665)

Pursuant to your responses to (1) Generic Letter (GL) 89-10 on December 28,

1989, (2)

NRC letter dated July 13,

1990, and (3) the issues discussed in a telephone-conversation (tele-con) between NRC (Johnson) and Rochester Gas and Electric (RGSE, Wrobel) on February 13, 1992, the NRC licensing action for this activity is considered complete.

The tele-con of February 13, 1992, regarding NRC letter dated July 13,

1990, is documented as follows:

(1)

RG&E will utilize the "two stage" approach as outlined in GL 89-10 and discussed at the workshops, as applicable.

(2)

RG&E's proposed schedule for testing is consistent with the recommendations of GL 89-10.

Should these commitments

change, please inform the staff in writing.

Acceptability of your GL 89-10 program will be determined during a future NRC inspection.

TAC No. H75665 is considered closed.

Sincerely, cc:

See next page Original signed by Allen R. Johnson, Project Manager Project Directorate I-3 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation OFFICE PDI-LA PDI-3/PH AD PDI-3 NAME DATE MRu ok 92 AJohnson:mw J

er

/& 92 4 ~92 V

e

& 92 OFFICIAL REC RD COPY DOCUMENT NAME:

GIT75665.LTR 9203120275 920306 PDR ADOCK 05000244 P

PDR

Dr. Robert C. Necredy Ginna CC:

Thomas A. Moslak, Senior Resident Inspector R.E. Ginna Plant U.S. Nuclear Regulatory Commission 1503 Lake Road

Ontario, New York 14519 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Ns. Donna Ross Division of Policy Analysis 5 Planning New York State Energy Office Agency Building 2 Empire State Plaza
Albany, Hew Yor k 12223 Charlie Donaldson, Esq.

Assistant Attorney General New York Department of Law 120 Broadway New York, New York 10271 Nicholas S. Reynolds Winston 5 Strawn 1400 L St.

N.M.

Washington, DC 20005-3502 l1s. Thelma Mideman Director, Mayne County Emergency Hanagement Office Wayne County Emergency Operations Center 7370 Route 31

Lyons, New York 14489 Ns. Susan Perry Administrator, Monroe County Office of Emergency Preparedness 111 Mest Fall Road Rochester, New York 14620

DISTRIBUTION:

,--Docket-Fi-le-No. 50-244 NRC 8 'Local PDRs PDI-3 rf S. Varga W. Lazarus H. Rushbrook A. Johnson J.

Calvo J. Norberg, EHEB T. Scarbrough, ENEB A. T. Gody, Jr.

13E21 OGC (f/info only)

ACRS (10)

J. Linville, RI R. Lobel V. Nerses

1 I

J I I