Text

FORD

1

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RlDS)

CCESSION NBR:9201070052

DOC.DATE: 91/12/24

NOTARIZED: NO

DOCKET

FACIL:50-244 Robert

Emmet Ginna Nuclear Plant, Unit 1, Rochester

G

05000244

AUTH.NAME

AUTHOR AFFILIATION

LINVILLE,J.C.

Region

1 (Post

820201)

RECIP.NAME

RECIPIENT AFFILIATION

MECREDY,R.C. 'ochester

Gas

& Electric Corp.

i

SUBJECT:

Forwards insp rept 50-244/91-27

on 911105-1209.No violations

or programmatic

weaknesses

identified.

DISTRIBUTION CODE:

IEOID

COPIES

RECEIVED:LTRj ENCL Q

SIZE: 0 4 l7

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

NOTES:License

Exp date in accordance

with 10CFR2,2.109(9/19/72).

E

05000244

31

RECIPIENT

ID CODE/NAME

PD1-3

PD

INTERNAL: AEOD

AEOD/DSP/TPAB

'RR

HARBUCK,C.

NRR/DLPQ/LHFBPT

NRR/DOEA/OEAB

NRR/DST/DIR 8E2

NUDOCS-ABSTRACT

OGC/HDS1

RGN1

FILE

01

EXTERNAL

EG&G/BRYCE P J

~ H ~

NSIC

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1'

1

1

1

1

1

RECIPIENT

'ID CODE/NAME

JOHNSONPA

AEOD/DEIIB

DEDRO

NRR MORISSEAUPD

NRR/DLPQ/LPEB10

NRR/DREP/PEPB9H

NRR/PMAS/ILRB12

OE

D

RE~RE

02

NRC PDR

COPIES

LTTR ENCL

1

1

1,.

1

1

1

1

~ 1

1

1

1

1

1

1

1

1

1

1

1

1

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

22

ENCL

22

~ ,

~

i

Docket No. 50-244

Rochester

Gas and Electric Corporation (RGB')

ATTN: Dr. Robert C. Mecredy

Vice President,

Ginna Nuclear Production

89 East Avenue

Rochester,

New York 14649

Dear Dr. Mecredy:

Subject:

R. E. Ginna Resident Inspection 50-244/91-27 (11/5/91 - 12/9/91)

From November 5 to December 9, 1991, the NRC Region I staff conducted

a routine safety

inspection at your facility. We have documented

the results in the enclosed report.

At the

end of the inspection, Mr.'T. Moslak of my staff summarized

the findings with Mr. J.

Widay and other members of your staff.

E

Within this scope,

the skill demonstrated

by operators in response

to challenges

to plant

stability from malfunctions of the feedwater and turbine control systems and automatic rod

~ control system was noteworthy.

Also, the support provided by the site engineering staff in

identifying and resolving the cause of electrical interferences in the feedwater control system

was effective.

No violations or programmatic weaknesses

were identified.

No response

to this letter is required.

Thank you for your cooperation.

Sincerely,

Origina} Signed

By:

James

C. L>nv<lle

James

C. Linville, Chief

Projects Branch 3

Division of Reactor Projects

Enclosure: NRC Region I Inspection Report 50-244/91-27

9201070052

911224

PDR

ADOCK 05000244

8

PDR

OFFICIALRECORD CQPY

a

~

tl

41

Rochest'er

Gas and Electric Corporation

cc w/encl:

R. Smith, Sr. Vice President, Production and Engineering

Central Records (4 copies)

Director, Power Division

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New York, Department of Law

State of New York, SLO Designee

Ginna Service List

K. Abraham, PAO (2)

Rochester

Gas and Electric Corporation

bcc w/encl:

Region I Docket Roo'm (with concurrences)

Management Assistant, DRMA (w/o encls)

W. Lazarus, DRP

A. Johnson, PM, NRR

W. Butler, NRR

L. Linville, DRP

R. Lobel, EDO

J. Joyner, DRSS

DRS SALP Coordinator

DRSS SALP Coordinator

P. Boehnert, Chairman, ACRS

bcc w/Letter and Overview of Findings only:

C. Hehl, DRP

J. Wiggins, DRP

W. Hodges, DRS

J. Durr, DRS

L. Bettenhausen,

DRS

. Knapp, DRSS

. Butler, NRR

O~g gg$9)

RI'DRP

RI:

RP

RI:D

Moslak/meo

12/19/91

vill

(L zA

OFF<ICIALRECORD COPY

A:GIN9127.MEO

~ I

)

R E

INNA ERVICE LIST

Resident Inspector

R. E. Ginna Plant

'U.S. Nuclear Regulatory Commission

1503 Lake Road

Ontario, New York

14519

Charlie Donaldson, Esq.

Assistant Attorney General

New York Department of Law

120 Broadway

New York, New York

10271

Ms. Donna Ross

Division of Policy Analysis 8c

Planning

New York State Energy Office

Agency Building 2

Empire State Plaza

Albany, New York,12223

Nicholas S. Reynolds

Winston & Strawn

1400 L. Street, N.W.

Washington, D.C.

20005-3502

Regional Administrator, Region I

U.S. Nuclear Regulatory Commission

475 Allendale Road

King of Prussia, Pennsylvania

19406

I