ACCELERATED DI UTION. DEMONST TION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9111050276 DOC.DATE: 91/10/28 NOTARIZED: NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G
AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.
Rochester Gas
& Electric Corp.
RECIP.NAME RECIPIENT AFFILIATION JOHNSON,A.R.
Project Directorate I-3
SUBJECT:
Provides notification re intention to substitute inservice insp exams of two Class 2 welds from steam generator "B" to identical welds on steam cIenerator "A".Two SG ASME Class 2
welds scheduled for exam identified on encl Figure 1.
DISTRIBUTION CODE A048D COPIES RECEIVED'LTR
( ENCL L SIZE TITLE: OR/Licensing Submittal:
Equipment Qualify'.cation DOCKET g
05000244 NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
05000244 RECIPIENT ID CODE/NAME PDl-3 LA JOHNSON,A INTERNAL: NRR/DET/EMEB 7E OC B
REG I 01 EXTERNAL: NRC PDR COPIES LTTR ENCL 1
0 1
1 1
1 1
0 1
1 1
1 RECIPIENT ID CODE/NAME PD1-3 PD NRR/DET/ESGB 8D OGC/HDS1 RES/DSIR/EIB NSIC COPIES LTTR ENCL 1
0 1
1 1
1 1
1 1
1 D
D D
NOTE TO ALL"RIDS" RECIPIENTS:
D D
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROiVI DISI'RIBUTION LISTS FOR DOCUMEIiS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 11 ENCL 8
/////////
/I/l/1//Si//
mitgj(jr~
reran
/ i~ra(EIZ
)iurs~ui ROCHESTER GAS AND ELECTRIC CORPORATION 89 EAST AVENUE, ROCHESTER N. Y. 14649.000'I ROBERT C MECREDY Vice President Cinna Nuclear Production October 28, 1991 TELEPHONE AREACODE 71B 546 2700 J.S. Nuclear Regulatory Commission Document Control Desk Attn:
Allen R. Johnson Project Directorate I-3 Washington, D.C.
20555
Subject:
Quality Assurance Manual, Appendix B Ginna Nuclear Power Plant Inservice Inspection ASME Section XI Steam Generator Examination Requirements R.E.
Ginna Nuclear Power Plant Docket No. 50-244
Dear Mr. Johnson:
The purpose of this letter is to provide notification concerning RG&E's intention to substitute ISI examinations of two (2)
Steam Generator ASME Class 2 welds.
Specifically, we intend to substi-tute examinations of two (2)
Class 2 welds from Steam Generator (S/G)
"B" to the identical welds on S/G "A".
The examination requirements for Steam Generators that are Class 2 components are specified within Table IWC-2500-1.
ASME Section XI IWC-2412, "Inspection Program B" provides details related to the inspection interval.
Presently, certain ISI examinations are scheduled to be performed.
on Steam Generator "B" between 1992 and. 1995.
The two (2)
welds scheduled.
for examination.
are identified on attached Figure 1 as the "Tube Sheet to Ring Weld" (Category C-A, Item C1.30) and "Lower Shell to Transition Weld."
(Category C-A, Item C1.10).
A Preservice and two (2) Inservice examinations have been performed on both of these welds on the "B" Steam Generator.
Review of examination records did not reveal any deficiencies.
The action to substitute examinations from S/G "B" to "A" for two (2) identical welds conforms with ASME Section XI IWC'-2420(a) in that the established schedule of Steam Generator examinations are being repeated, to the extent practical.
The outcome of the Code allowed alternative will provide the following benefits:
(1)
Substantial reduction in personnel asbestos exposure and an expected personnel dose reduction of up to 220 rem, and 9iii050276 9ii028
'PDR ADOCK 05000244 "9
PDR PrPXV
I'I I
Il
. I n
(2)
Significant reduction of man-hours to perform scaffolding installation, insulation removal, re-insulation and scaf-folding removal.
Since this approach conforms with code requirements, prior NRC approval should not be required.
Therefore, we do not expect a
response from the Commission.
Very truly yours, Robert C.
Mec edy GAL/191 xc: Mr. Allen R. Johnson (Mail Stop 14D1)
Project Directorate I-3 Washington, D.C.
20555 U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Ginna Senior Resident Inspector
FIGURE I
(9Z)
UPPER SHELL TO HEAD WELD USH-A (9Z)
LOWER SHELL TO TRANSITION WELD LST-B (95)'US-A TRANSITION TO UPPER SHELL WELD SUBSTITUTED FROM "B" S/G TO "A" S/
(94)
TUBESHEET TO RING WELD TSRW-B 0
0 SUBSTITUED FROM "B" S/G TO "A" S/G
"(93)
LOWER HEAD TO TUBE SHEET WELD LHTSW-A
f 4