Forwards Safety Insp Rept 50-244/91-21 on 910910-12.No Violations or Deviations Noted.Performance of Personnel Demonstrated Ability to Implement Emergency Plan & EPIP in Manner That Would Provide Protective Measures for Public
ML17262A622
Person / Time
Site: Ginna Constellation icon.png
Issue date: 10/10/1991
From: Joyner J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
Shared Package
ML17262A623 List:
References
NUDOCS 9110240002
Download: ML17262A622 (6)


See also: IR 05000244/1991021

Text

OCT

1 0 iggl

Docket No. 50-244

License No. DPR-18

Dr. Robert C. Mecredy

Vice President

Ginna Nuclear Production

Rochester Gas and Electric Corporation

89 East Avenue

Rochester, New York 14649

Dear Dr. Mecredy:

Subject:

Inspection No.

50-244/91-21

A routine safety inspection ofyour annual emergency preparedness

exercise was conducted

by Mr. L. Eckert of this office and other members of an NRC team on September

10-12,

1991 at the R. E. Ginna Nuclear Power Plant, Ontario, New York.

Discussions of our

findings were held by Mr. Eckert with you and other members ofyour staff at the conclusion

of the inspection.

The areas examined during this inspection are described in the NRC Region I report which

is enclosed with this letter. Within these areas, the inspection consisted of examination of

procedures

and records,

interviews with personnel,

and observation

of the emergency

exercise by NRC team members.

Performance

of Rochester

Gas and Electric Corporation personnel

during the exercise

demonstrated

the

ability to implement

the

Emergency

Plan

and

Emergency

Plan

Implementing Procedures in a manner that would provide adequate protective measures for

the health and safety of the public.

Within the scope of this inspection, no violations or

deviations were identified and several exercise strengths were noted.

No reply to this letter is indicated.

Your cooperation with us in this matter is appreciated.

Eg r

9iiOZ4000Z 9iiOiO

PDR

ADOCK 05000244

Q

PDR

'

Rochester

Gas and Electric Corporation

2

Sincerely,

Original Signed

By:

James

H. Joyner

James H. Joyner, Chief

Facilities Radiological Safety

and Safeguards Branch

Division of Radiation Safety

and Safeguards

OCT g0 l8

Enclosure:

Inspection Report No. 50-244/91-21

cc w/encl:

R. Smith, Senior Vice President, Production and Engineering

Central Records (4)

Director, Power Division

State of New York, Department of Law

Ginna Service List

Public Docket Room (PDR)

Local Public Docket Room (LPDR)

Nuclear Safety Information Center (NSIC)

K. Abraham, PAO (2)

NRC Resident Inspector

State of New York, SLO Designee

Rochester Gas and Electric Corporation

3

bcc w/encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA(w/o encl)

DRS SALP Coordinator

DRSS SALP Coordinator

J. Joyner, DRSS

L. Linville, DPR

E. McCabe, DRP

A. Johnson, PM, NRR

K. Brockman, EDO

OCT

1 0

tgg~

CONCURRENCES:

DRSS:RI

DRSS:RI

DRSS:RI

DRSS:RI

Eckert

10/7/91

Cb5

Gordon

10/3t/91

Ak; ~

OFFICIALRECORD COPY

R.

E.

GINNA SERVICE LIST

Resident

Inspector

R.

E. Ginna Plant

U.S. Nuclear Regulatory

Commission

1503

Lake

Road

Ontario,

New York

14519

Charlie Donaldson,

Esq.

Assistant Attorney General

New York Department of Law

120 Broadway

New York,

New York

10271

Ms.

Donna

Ross

Division of Policy Analysis

8

Planning

New York State

Energy Office

Agency Building 2

Empire State

Plaza

Albany,

New York

12223

Nicholas

S.

Reynolds

Winston

8 Strawn

1400

L St.,

N.W.

Washington,

DC

20005-3502

Regional Administrator,

Region I

U.S. Nuclear Regulatory

Commission

475 Allendale

Road

King of Prussia,

Pennsylvania

19406