A CELERATED DISTRIBUTION DEMONSTRATION SYSTEM t
t REGULATORY INFORMATXON DISTRXBUTXON SYSTEM (RIDS)
ACCESSION NBR:9104040156 DOC.DATE: 91/03/27 NOTARIZED: NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G
AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.
Rochester Gas
& Electric Corp.
RECIP.NAME RECXPXENT AFFILIATION JOHNSON,A.R.
Project Directorate I-3
SUBJECT:
Suppls 891228 response to Generic Ltr 89-10 re safety related motor-operated valve (MOV) testing
& surveillance.
MOV program description revised re design pressure testing in parallel train of identical MOVs.
DISTRIBUTION CODE:
A064D COPXES RECEIVED:LTR ~ ENCL N SIZE:
TITLE: Response to Generic Ltr 89-10, "Safety-R lated MOV Testing NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
DOCKET 05000244 t
Surveill 0
05000244 RECIPIENT ID CODE/NAME PDl-3 LA JOHNSON,A INTERNAL BAER F B RES NRR/LPEB/BC RES/DSIR/EIB/B EXTERNAL: NRC PDR COPXES LTTR ENCL RECIPIENT ID CODE/NAME PD1-3 PD NRBJ EMEB 7E O g NSIC COPXES LTTR ENCL D
NOTE TO ALL"RIDS" RECIPIENTS:
D D
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 10 ENCL
//
//////
/I/
///////I////
IE~/////////
////I//I///
ROCHESTER GAS AND ELECTRIC CORPORATION rrtv Lka ~ ocr@~
j 'tere o
89 EAST AVENUE, ROCHESTER N.Y. 1464S-0001 ROBERT G MECREDY Vlcc President Ctnne Nudeer Produodon March 27, 1991 TELEPHONE AREACODE7tB 54B 2700 U.S. Nuclear Regulatory Commission Document Control Desk Attn:
Allen R. Johnson Project Directorate I-3 Washington, D.C.
20555
Subject:
Generic Letter 89-10:
Clarification to Program R.E.
Ginna Nuclear Power Plant Docket No. 50-244
Reference:
1.
Letter from R.
C. Mecredy (RGGE) to A. R. Johnson (NRC), "Response to Generic Letter 89-10 (6 Month)
Safety-Related MOV Testing and Surveillance,"
dated December 28, 1989.
Dear Mr. Johnson:
In reference 1
Rochester Gas and Electric Corporation (RGGE) submitted a six-month response to Generic Letter 89-10 'briefly describing the methods by which RGGE intends to meet the Gl 89-10 recommendations.
On page 2 of the response, RGGE states that "MOVs in the above systems will be tested at design pressure when practical."
Since six-month response was written, several supplements to GL 89-10 have been issued, including the results of public workshops designed to clarify the intent of the generic letter.
On Page 27 of Supplement 2 to GL 89-10, the staff's response to Question 29 states that test data from an MOV tested under desi,gn-basis conditions could be used to demonstrate operability of an identical MOV in a parallel train if justified properly.
Therefore, RG&E is revising the MOV Program description to require that design-basis DP testing be required to be. performed.
on only one MOV in a parallel train of identical MOVs, provided.'dequate margin above the thrust required to overcome DP is demonstrated.
If DP test results are satisfactory but adequate margin does not exist, the other valves in the parallel train will be DP tested.
Very truly yours, RWE/153 Attachment r9i04040i56 9i0327