Forwards Application for Amend to License DPR-18,revising Heatup/Cooldown Curves & Associated Low Temp Overpressure Protection Setpoint to Implement Reg Guide 1.99,Rev 2 Methodology.Encl Proprietary Rept Withheld
Date released: 04/30/2018 Download: ML17262A376


Forwards Application for Amend to License DPR-18,revising Heatup/Cooldown Curves & Associated Low Temp Overpressure Protection Setpoint to Implement Reg Guide 1.99,Rev 2 Methodology.Encl Proprietary Rept Withheld
ML17309A455
Person / Time
Site: Ginna 
Issue date: 02/15/1991
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To: JOHNSON A R
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
References
RTR-REGGD-01.099, RTR-REGGD-1.099
Download: ML17309A455 (3)
Nonproprietary Re Ginna Low Temp Overpressure Protection Sys Setpoint Phase II Evaluation, Final Rept
ML17262A378
Person / Time
Site: Ginna 
Issue date: 02/28/1991
From:
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17262A378 (20)
Proposed Tech Specs Revising Heatup/Cooldown Curves & Associated Low Temp Overpressure Protection Setpoint to Implement Reg Guide 1.99,Rev 2 Methodology
ML17262A377
Person / Time
Site: Ginna 
Issue date: 02/15/1991
From:
ROCHESTER GAS & ELECTRIC CORP.
To:
References
RTR-REGGD-01.099, RTR-REGGD-1.099
Download: ML17262A377 (19)
Application for Amend to License DPR-18,revising Heatup/Cooldown Curves & Associated Low Temp Overpressure Protection Setpoint to Implement Reg Guide 1.99,Rev 2 Methodology
ML17262A375
Person / Time
Site: Ginna 
Issue date: 02/15/1991
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To:
References
RTR-REGGD-01.099, RTR-REGGD-1.099
Download: ML17262A375 (3)