ACCELERATED 'DISIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9010230195 DOC ~ DATE: 90/10/10 NOTARIZED:
NO DOCKET FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G
05000244 AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.
Rochester Gas
& Electric Corp.
RECIP.NAME RECIPIENT AFFILIATION JOHNSON,A.R.
Project Directorate I-3
SUBJECT:
Updates status of inoperable Fire Damper I-411-21-P-DISTRIBUTION CODE:
IE22D COPIES RECEIVED:LTR g ENCL C
SIZE:
TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.
D NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
05000244
/
RECIPIENT ID CODE/NAME PDl-3 LA JOHNSON,A INTERNAL: ACNW AEOD/DSP/TPAB NRR/DET/ECMB 9H NRR/DLPQ/LHFB11 NRR/DREP/PRPB11 NRR/DST/SICB 7E NRR/DST/SRXB SE RES/DSIR/EIB EXTERNAL: EG&G BRYCE,J.H, NRC PDR NSIC MURPHY,G.A COPIES LTTR ENCL 2
1 1
1 2
1 1
1 RECIPIENT ID CODE/NAME PD1-3 PD AEOD/DOA AEOD/ROAB/DSP NRR/DET/EMEB 7E NRR/DLPQ/LPEB10 NRR/DST/SELB SD
~NRR/~LBSD1 RGN1 FILE 01 L ST LOBBY WARD NSIC MAYS,G NUDOCS FULL TXT COPIES LTTR ENCL 1
2 1
1 1
1 1
1 D
D
/Vo pq~ q'
( ff D
NOTE TO ALL"RIDS" RECIPIENTS D
D PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 30 ENCL'15
ROCHESTER GAS AND ELECTRIC CORPORATION ROBER7 C. h1ECREDT Vice Pceiideni Cinna Nucleac Psnduccinn LIP sx
. c Teea 7
Sea!C
~
89 EAST AVENUE, ROCHESTER N.Y. 14649-0001 TELEPHONE AREACOOE 716 546 2700 October 10, 1990 Mr. Allen R. Johnson Project Directorate I-3 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
Subject:
Change to Thirty (30) Day Special Report Inoperable Pire Damper I-411-21-P R.E.
Ginna Nuclear Power Plant, Unit No.
1 Docket No. 50-244
Reference:
Letter from R.C. Mecredy (RG&E) to A.R. Johnson (NRC)
Dated July 31, 1990.
Dear Mr. Johnson:
The purpose of this letter is to update the status of inoperable fire damper I-411-21-P.
Ruskin, the manufacturer of this damper, has been contacted and asked to comment on a design to install a removable track to replace the one side track that interferes with removal of the charcoal drawers that are behind the damper.
Their response was that they will have to submit this design to Underwriters Laboratory for review and comment/approval.
We are in the process of contracting for this review at this time.
Since this review will take several.weeks, we are, in parallel, preparing a design/installation package to 'replace this damper with a larger damper and opening.
As a result, we will not lose the time that it will take to get the results from Underwriters Laboratory should the review come back that a removable side track is not an approved configuration.
In either instance, we will have the necessary modification designed and installed by July 31, 1991.
The established hourly fire watch in accordance with Technical Specification 3.14.6.1 will remain in effect.
VO1 V$~4CT f>g p(TLLTg PDF:
ADOCIE. O=OOO24<
PDC b
~Dc
ROCHESTER GAS AND ELECTRIC CORP.
OATE 10/10/90 Mr. Allen R. Johnson SHEET HO.
2
~?ery truly yours, Robert C. Mecredy xc:
Ginna Senior Resident Inspector
'tJ.S.
Nuclear Regulatory Commission Region 1
475 Allendale Road King of Prussia, PA 19406