ACCELERATED DARIBUTJON DEMONS'l%ATtON SYSTEM ACCESSION NBR:88 FACIL:50-244 Robert Emmet Gonna Nuclear Plan n

AUTH.NAME AUTHOR AFFILIATION MCNAMARA,A.E.

Rochester Gas

& Electric Corp.

KOBER,R.W.

Rochester Gas 8 Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS) 01040478 DOC.DATE: 87/11/30 NOTARIZED: NO DOCKET t

U it 1 Rochester G

05000244

SUBJECT:

Monthly operating rept for Nov 1987.W/871211 ltr.

DISTRIBUTION CODE:

IE24D COPIES RECEIVED:LTRj ENCL J SIZE:

TITLE: Monthly Operating Report (per Tech Specs)

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72)-

05000244 D

RECIPIENT ID CODE/NAME PDl-3 LA STAHLE,C INTERNAL: AEOD/DOA ARM TECH ADV NRR/DOEA/EAB NRR/PMAS/ILRB RGN1 EXTERNAL: DOE NE32 FULNER NRC PDR COPIES LTTR ENCL 1

0 1

0 1

1 2

2 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD1-3 PD AEOD/DSP/TPAB NRR/DLPQ/PEB NRR/DRE RPB

&~@

01 LPDR NSIC 1

1 1

1 1

1 1

1 D

-8 1

1 1

1 PU P p 8

COPIES LTTR ENCL 5

5

'A D

I" 8

I A,

D'OTAL NUMBER OF COPIES REQUIRED:

LTTR 21 ENCL 19

f~~j ~/++

hA

'b gf

~'"

'I c

~

".l l

~~

OPERhTING SThTUS OPERATIHG DATA REPORT DOCKET NO.

DhTE December ll 1987 COMPLETED BY Andrew E. McNamara TELFPHONE 315 524 Ginna Station 470

1. Unic Name:

R.E. 6INNA NUCLEAR POWER PLANT

2. Reporting Period:
3. Licensed Thermal Power (MWc):
4. Nameplate Rating (Gross MWe):
5. Design Elccn ical Rating (Nec MWe):
7. Maximum Dependable Capacity (Ncc MWe):

Notes The reactor power level was maintained at 100% for the entire report period, with one exception, detailed on page 4.

8. IfChanges Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Rcport, Give Reasons:
9. Power Level to Which Rescricted, Ifhny (Net MWc)r
10. Reasons For Restrictions, If hny:

This Month Yr:to-Date Cumulative 720 8 016.00 7-270 0

10 764 007 3 615 605 100%

90.44%

90.44%

91.25%

11. Hours In Reporting Period
12. Number of Hours Reactor Was Ctitical 720
13. Reactor Reserve Shutdown Hours 0
14. Hours Generator On-Line
15. Unit Reserve Shucdown Hours
16. Gross Thermal Energy Gc.aerated (MWH)
17. Gross Electrical Energy Gencratcd (MWH) 396 653
19. Unit Scrvicc Factor
20. Unic hvailability Factor 100%
21. Unit Capacity Factor (Using MDC Nec) 103.98%
23. Unit Forced Outage Rate 0%

0%

24. Shutdowns Scheduled Over Next 6 Months (Type, Dace and Duration of Each):

Februa 5

1988 Annual R fu li 157 896.00 123 274.47 169 814 056 55 704 217 76.59 76.60%

72.70%

6.55%

25. If Shut Down ht End Of Rcport. Period, Escimaced Dace of Scarcup:
26. Units ln Test Status (Prior to Commercial Operation):

INITIhL.CRITIChLITY INITIhLELECTRICITY COMMERCIhL OPERhTION Forecast hchicvcd

  • Cummulative Total. Comm 8801040478 871130.'

I

PDR,

.ADOCK 05000244

.. DCD

"""ing January 1

1975 xcv. kg Ig.cs

I

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-2 UNIT G

DATE e

embe COMPLETED BY e

owe Plant 9

7 MONTH Novemb 87 TELEPHONE Andrew E.

cNamara Ext.

301 at Ginna DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 2 ~

3 ~

4 ~

5 ~

6 ~

DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 17 ~

18 ~

19 ~

20

'1

~

22 ~

7 ~

8 ~

9 ~

10

'2

~

13.

14

'5

~

16 ~

490 4

0 0

489 88 23

'4

'5.

26 ~

27 ~

28

'9

'0

~

31.

90 489 48 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

yt

REPORT MONTH pl 1)O(:Kl'.T NO.

~0 244

~

'INI'I'NhMI:

R.E. GINNA NUCLEAR POWER PLANT'NIT SHUTDOWN AND POWER REDUCTIONS

(:OMPLI'.'I'I'.I)IIY Andrew E.

McNamara I'I:LEPIIONI:

Ginna Stat/on Ho.

Date o e 4

DP 0 C0N De nc ca 8 ocu D

o L ~

> cx.'

IA D CS Licensee Event Report N

Ew N 0

~A C~ LrS 0C o<

E O

Cause 8 Corrective Action to Prevent Recurrence No outages or significant power reductions to report 1

F:

Forced S:

Scheduled htv. 4I$$

4$49 2

Reason:

h-Equipment Failure (Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E&perator Training gt License Examination F-hdministrative G&peracional Error (Explain)

)H)ther (Explain)

Method:

14lanua) 2-Manual Scram.

3-hutomatic Scram.

4-Other (Explain)

Fxhibit G - lnsuuccions for Preparation of Data Entry Sheets for Licensee Event Report (LER) File (NUREG-0)61)

Exhibit I - Same Source

N2QG&TIVE

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 5-4 Gi a Nuc ea owe P a t e

mb 1

1 87 Ctyvc~~

Andrew E. McNamara 15 2 -4 4

EXT. 301 at Ginna

,MONTH Nov mber 7

The unit operated at 100% reactor power level for the ma)ority of the report period, with one minor exception:

On ll/13 the reactor power level was reduced to - 974 for a short period to perform a Periodic Test on the Auxiliary Feedwater System.

GINNA STATION MAINTENANCE REPORT

SUMMARY

NOVEMBER, 1987 During the month of November, routine maintenance and inspections were completed.

Major safety related work included:

a ~

b.

c ~

d ~

Aux. Bldg. Charcoal Filters - change out Repair Copper Line to Turbine Driven Aux.

FW Pump Test RV-283 - "C" Charging Pump Snubber Inspection per M-40 e.

Repair Heat Exchanger Tubing on "C" Safety In).

Pump f.

Repair

'!C" Standby Aux.

FW Cooling Unit go h.

k.

"C" Charging Pump Vari Drive - Trouble shoot and lubricate TSC Diysel << PT-12.5 Surveillance Security Diesel - Annual Maintenance MOV-4008 - MOVATS Testing Diesel Fire Pump Engine/Pump Maintenance Personnel/Equipment Air Lock PT-22.1/PT>>22.4 Surveillance

1 E'

~d <+i ROCHESTER GAS AND ELECTRIC CORPORATION

~ 89 EAST AVENUE, ROCHEST R. N.K 14649-0001 ROGER w. RABBER

.1CC PRKSIO&kT c~cc~wc ~covcno~

t &

~ ()

i-ci conc (o 5-'o 2700 GINNA STATION December ll, 1987 Director, Office of Management Information and Program Analysis U.S.

NUCLEAR REGULATORY COMMISSION Washington, DC. 20555 Sub) ect:

Monthly Report for November, 1987 Operating Status Information R. E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Sir:

Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report for Ginna Station for the month of November, 1987.

V truly yours, sp

&'ogerW. Kober RWK/eeh Attachments cc:

Mr. William T. Russell NRC (1)

P J

I'p