~ R I ~1y wg ~

ROCHESTER GAS AND ELECTRIC CORPORATION o

89 EAST AVENUE, ROCHESTER, N.Y. 14649 JOHN E.

41A I ~~R VICE PRESloENr 1EI.ER>O>E AREA COOE 1lC 5 J6 2700 M y Mr. Boyce H. Grier, Director Region I Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

IE Bulletin 81-02 Failure of Gate Type Valves to Close Against Differential Pressure R.E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Grier:

None of the valves identified in IE Bulletin 81-02 are installed or are being maintained as spares for installation at the specified service conditions in safety related systems at Ginna.

Approximately four hours was required for preparation and review of this response.

Very truly yours, J.

E. Maier Subscribed and sworn to me on this 8th day of May, 1981.

cc: Director, NRC Office of Inspection 6 Enforcement Washington, D. C.

20555 SE i'i"ARtE PERROiRE

. Y.. tIto,",ro: Courty

',t r,;,'," >>;i

~ 1 r 1 C,'AB O~R @i~

Il ~

h

~

ll. I I Ifl

~

/

tl'~