ML17258A750
| ML17258A750 | |
| Person / Time | |
|---|---|
| Site: | Ginna |
| Issue date: | 01/28/1981 |
| From: | Maier J ROCHESTER GAS & ELECTRIC CORP. |
| To: | Crutchfield D Office of Nuclear Reactor Regulation |
| References | |
| TASK-07-01.A, TASK-7-1.A, TASK-RR NUDOCS 8102040390 | |
| Download: ML17258A750 (4) | |
Text
REGULATORY NFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:8102000390
-DOC ~ DATE: 81/01/28 NOTARI iD:
NO DOCKET FACIL:50 244 Robert Emmet Ginqa Nuclear Plant<
Unit-1E Rochester G
05000200 AUTH SHAME AUTHOR AFFILIATION MAIER-<J,E, Rochester Gas 8 Electric Corp.
RECIP ~ NAME>
RECIPIENT AFFILIATION CRUTCHF IELD E D ~
Operating. Reactors Branch 5
SUBJECT:
Responds to NRC 801212'tr re SEP topic YII f,aE"Reactor Protection Sys Isolation."Agrees w/assessment info 8
designates topic completely DISTRISUTION CODE:
A0350 COPIES RECEIVED:LTR g'NCL J2 SIZE:
TITLE: SEP Topics NOTES:1 copy;SEP Sect.
- Ldr, 05000204 RECIP IENT ID CODE/NAME ACTION:
CRUTCHF IELD 0q INTERNAL; A/D MATLEQUAL13 HYD/GEO BR 10 02'G F IL 01 COPIES LTTR ENCL RECIPIENT ID CODE/NAME CONT SYS A
07 IEE 06 OR ASSESS BR 11 SEP BR 12" COPIES LTTR ENCL'XTERNAL:
LPDR 03 Fgg O 5 1991 gg 0
TOTAL NUMBER OF COPIES REQUIRED:
LTTR ENCI
~
~
l
'tt fI lf
I
/ /WEflW // Itlldfl u&jjztirizizsiz 8
//ESill Stilt ROCHESTER GAS AND ELECTRIC CORPORATION o
S9 EAST AVENUE, ROCHESTER, N.Y. 14649 JOHN VICE
~b-O'A su<'>
~'.
MA I ER PRKSIOENT bQ CQ ct
'A CA70 W
CQi CC c,g~-.
c~
JA/
I CPP cd January 28, 1981 Tc cc IIH0 N c Asc* cooc 7ie 546.2700 Director of Nuclear Reactor Regulation ATTN:
Mr. Dennis M. Crutchfield, Chief Operating Reactors Branch 55 U.S. Nuclear Regulatory Commission Washington, D.C.
20555
Subject:
SEP Topic VII-1.A, Reactor Protection System Isolation R.
E. Ginna Nuclear Power Plant Docket No. 50-244
Dear Mr. Crutchfield:
Rochester Gas and Electric has reviewed the NRC's assessment of SEP Topic VII-1.A, "Reactor Protection System Isolation,"
transmitted by letter dated December 12, 1980.
We agree that the information in the assessment is correct.
Since the assess-ment determined that the isolation of the reactor protection system from non-safety systems satisfies the current licensing
- criteria, we have designated this topic as complete.
Very truly yours, Jo n E. Maier
o~~
W
~
I II
.ll l
4 lv
'W 1
Jj