ATTACHMEiVT 2 NUREG-0737 TOPIC III.D.3.4 CONTROL ROOM HABITABILITY R. E.

GINNA NUCLEAR PONER PLANT Rochester Gas

& Electric Corporation September 1981 8109100173 810904 PDR

  • DOCK 05000244 P

PDR

ii r

I t

RG&E Res onse to NUREG 0737 To ic III.D.3.4, Control Room Flabitabilit Re uirements 1.0 Summar and Conclusions An evaluation has been performed to assess the impact upon control room habitability of the postulated accidental release of toxic gases either onsite or offsite, and of radioactivity releases resulting from the design basis loss-of-coolant accident.

The toxic gas accident analysis accounted for potentially significant hazardous chemicals identified on the Ginna site and within 5 miles of the plant.

The results of the radiological evaluation indicate acceptable post-accident doses to control room operators if credit is taken for the operation of the control room ventilation/filtration system.

Modifications are proposed for more rapid control room isolation capability to assure acceptable operator

doses, even in the event the ventilation/filtration system is assumed to be in-operable.

The toxic chemical evaluation has identified potentially high control room concentrations of chlorine and ammonia from offsite and onsite sources, respectively.

Preliminary modification recommendations include provisions for rapid detection of these chemicals, along with the capability to automatically isolate the control room ventilation from the outside environment.

Additional areas warranting modifications or further investigation are also discussed.

These include ductwork modifications to provide additional assurance that an appropriate portion of recirculated control building air is being filtered, and an investigation to improve the residence time of air flowing through the control room charcoal filter banks.

2.0 Radiolo ical Anal sis Table A presents cases evaluated in the Ginna control room habitability study which are pertinent to the discussion of suggested modifications which follows.

Case 1 approxi-mates the present. control room system configuration as described under Appendix A, Item 1:

Mode of 0 eration.

It is seen that with credit, taken for the operation of the control room ventilation/filtration system, the General Design Criteria 19 (GDC-19) limits for thyroid and whole body dose are met following a postulated loss-of-coolant accident.

This includes dose contributions from airborne radioactive. materials inhaled and from direct radiation.

The dose contribution due to emergency safety feature (ESF) leakage was determined to be approxi-mately 5 percent of the thyroid dose, and approximately 1 percent of the whole body dose.

Case 2 is presented to show the doses resulting from assumed unavailability of control room air filtration following an accident.

In this case, the effects of two proposed modifications are apparent.

First, it is assumed that. rapid control room isolation can be achieved by relocating radiation detection equipment nearer to the control building outside make-up air intake.

Secondly, a smaller-sized inlet damper is assumed, which limits the maximum outside air flow into the control building prior to post-accident isolation.

The thyroid and whole body doses are shown to be within the GDC-19 guidelines.

The assumptions used in arriving at these conclusions are shown on Table A.

Additional information requested by Attachment 1 to NUREG-0737, Item III.D.3.4, is included in Appendix A of this report.

S 0

TABLE A Assumptions and Results of Ginna Control Room Habitability Radiological Evaluation Parameter Case 1

Case 2

Reactor Power (HWt)

Halogens:

El/Or/Part fraction Spray initiation/duration (min)

Halogen removal Spray (hr

)

CV recirc. filter credit CV volume leak rate (1st day)

CV volume leak rate (thereafter) 0-8 hr X/Q (sec/m

)

Pre-isolation CR intake (cfm)

CR isolation time (sec)

Unfiltered in-leakage (hr 1)

Recirc. rate (908 filter)

Breathing rate (m /sec) 3 Occupancy 1520

.91/.04/.05 2/28 10 Yes 0.002/day 0.001/day 1.9 x 10 4

16,000 30 0 F 06 2048 cfm 3.47 x 10 4 partial 1520

.91/.04/.05 2/28 10 Yes 0.002/day 0.001/day 1.9 x 10 4 2,000 0.06 0 cfm 3.47 x 10 4 partial Thyroid dose (rem)

Whole body dose (rem) 8 '

1 ~ 0

15. 3 1 ~ 0 GDC-19 lim'."s:

Thyroid dose (rem)

Whole body (rem) 30 30

3.0 Onsite Toxic Chemical Surve and Anal sis 3.1 Onsite Chemical Survey Sources of chemicals identified during the Ginna onsite chemical survey included:

a 500 gallon anhydrous ammonia tank located next to the AVT building about 40 meters from the control room intake, a pair of 6,000 gallon tanks of 988 H2S04 and 50%

NaOH located in the AVT building about 40 meters from the control room and another pair in the primary water treatment plant about, 100 meters from the intake, several 55 gallon drums of 30%,

NH4OH, 50 gallon drums of 15%

NH4OH and 5% N2H4, and a

35 gallon drum of 358 N2H4 located in the turbine building about 75 meters from the intake, a variety of gas bottles maintained throughout the plant, and the bromotrifluoromethane tanks outside the computer rooms an underground sodium hypochlorite tank located near the plant screen house.

The effect, of each of these on control room habitability is discussed in Section 3.2.

Drawings indicating the locations of onsite chemicals are contained in Appendix 8 ~

3.2 Onsite Chemical Hazards Evaluation Toxic chemicals were evaluated in a manner similar to that performed for radioactivity.

For each chemical, applicable toxicity limits were identified, both catastrophic and slow leak accidents were hypothesized and the resulting "puff" or "plume" was modeled using appropriate diffusion equations.

a

~

It was determined that the 500 gallons of anhydrous ammonia stored near the AVT building poses a potentially significant problem with respect to control room concentrations following a postulated anhydrous ammonia tank or line rupture.

Post-accident control room ammonia concentrations were calculated to exceed a toxicity limit of 70'g/m following either type of rupture.

It has been concluded that modifica-tions are needed to provide the means to rapidly detect and isolate the control room in the presence of high outside ammonia concentrations.

Furthermore, it has been recommended that additional measures

be investigated addressing the ammonia hazard.

They may include additional diffusion analysis, in leakage verification, chemical substitution, tank enclosure or tank relocation.

b ~

The 6,000 gallon tanks of H2S04 and NaOH stored in the AVT building are contained in separate areas of large enough volume to contain the entire contents of both tanks.

Each area is drained to a common sump through separate lines.

Valves in the lines are maintained in the closed position so that no mixing of the NaOH and H2SO4 is likely to occur.

H2S04 is not considered a hazard to the control room operator unless heated as the result of dilution or mixture with caustic.

Neither is likely to occur.

C ~

The 6,000 gallon tanks of H2SO4 and NaOH stored in the primary water treatment facility sit next to each other about 100 meters from the intake.

Spills would be drained to the building floor drains leading to an underground retention tank.

These tanks are not considered a hazard to control room personnel.

d ~

The drums of NH4OH and N2H4 are dilute and stored in small quantities and thus are not considered a hazard.

e.

There are numerous gas bottles throughout the Ginna site (see Appendix B).

Individually, they do not pose a threat to the operators.

There is a large number of bottles stored in the main storage location on the north side of the turbine building.

These are securely attached to a number of metal racks which are themselves attached to the walls and floor.

There is not a potential for damage to a large number of bottles as the result of a single event.

Additional hydrogen bottles are stored and properly secured to the east and south of the Auxiliary Building.

The fire protection system used in the relay and computer rooms consists of two separate manually actuated Halon 1301 systems.

Bromotrifluoromethane is the fire control agent.

It is not generally considered a toxic hazard except as an asphyxiant.

The gas is much heavier than air and unless it is stirred up, it will settle to the floor.

The control room is above the computer room.

The system should not be activated unless a fire has been detected isolating the control room from the computer room.

However, if it is assumed that half the gas (640 pounds) is injected to an unisolated computer 6

room and that the gas is well mixed, concentrations as high as 2x10 mg/m may be attained.

This is less than the generally accepted limit for protective action (requiring use of self-contained breathing apparatus) of 5.9xl0 mg/m The Halon 1301 system does not pose a threat to control room habitability.

An underground sodium hypochlorite tank is located near the Screenhouse.

The tank contents are not highly volatile and do not pose a hazard to control room operators.

4.0 Offsite Toxic Chemical Surve and Anal sis 4.1 Offsite Chemical Survey A survey of toxic chemical sources within a five mile radius of the Ginna site was performed by RGSE personnel following a procedure described in Appendix C.

Federal, state, and local agencies were. contacted concerning their knowledge of toxic chemicals stored or transported through the area.

A railroad spur and Route 104 pass about 3.5 miles from the site (see Appendix C).

Companies that may use these routes were contacted.

The responses generated by the survey are documented in Appendix C.

a

~

The following chemicals were identified as in use by local fruit growers:

Guthion in 2 1/2 pound cases Vydate in 1 and 5 gallon cans Lannate in 1 and 5 gallon cans Methamidophos in 1 and 5 gallon cans Parathion in 5 gallon cans Furadan in 50 pound bags and 1 gallon cans Termik in 30 pound bags Demeton in 2 gallon cans These are transported to local distribution firms about 50 times per year.

b.

The following chemicals are located in the Ontario Agway Store about four miles from the site:

C ~

various pesticides in small containers liquid swimming pool chlorine 4,000 gallons of Nitan (32% nitrogen solution split evenly between urea and ammonium nitrate).

h The Town of Ontario's Water Plant about 1.1 miles from the site stores chlorine in two 2,000 pound tanks.

One tank is refilled each month from a truck containing 2,750 pounds of chlorine housed in a 2,000 pound cylinder and five 150 pound cylinders.

d.

The Coast Guard does not maintain records of chemical transport on the lake.

The normal shipping lanes are about 40 miles from the shore.

Vessels which may contain toxic chemicals are not normally seen from the vicinity of the site.

e.

Conrail has not researched traffic on the spur.

They will do so when time is available.

This spur is only lightly used and should not present a hazard.

4.2 Offsite Chemical Hazards Evaluation a ~

The 2,000 lb. tanks of liquid chlorine do pose a potential hazard to Ginna control room habitability, following a postulated catastrophic rupture with stable meteorology and no assumed chlorine detection system in proximity to the control room ventilation intake.

Following such a rupture, control room concentrations were calculated to exceed the short and, long-term toxicity limits (45 and 12 mg/m respectively) with the present control room design.

Xt has been determined that a modification to provide rapid chlorine detection and isolation capability would adequately ensure acceptable post-accident concentrations in the control room.

b ~

The truck which refills the chlorine tanks transports quantities of chlorine similar to those stored in each tank at the Ontario water treatment plant site.

Because these trucks transport the chlorine via Route

104, no additional hazard is presented beyond that already discussed in the previous paragraph.

C ~

The chemicals in use by local fruit growers such as Guthion, Vydate, Parathion, and Demetron are generally solids stored in small containers.

They are not stored in large quantities anywhere in the Ginna area.

d

~

The chemicals stored at the Ontario Agway Store consisted of pesticides such as those above stored in small containers, liquid swimming pool chlorine and 4,000 gallons of Nitan.

The small commercial quantities of pesticides and swimming pool chlorine are not considered to be toxic hazards.

Nitan is a liquid with a low vapor pressure at normal temperatures and pressures and does not present a threat to control room habitability.

'Jr

5.0 Modifications and Further Investi ations Relative to Control Room Habitabilit Evaluations of control room habitability for the Ginna plant have been performed under the SEP by NRC staff (see letter from D.

M. Crutchfield to J.

E. Maier, "Ginna SEP Topics VI-8 and II.1.C", received January 19, 1981) and subsequently by Rochester Gas and Electric Corporation (contained herein).

The following is a discussion of modifications presently contemplated based upon the result of these evaluations.

5.1 Radiological Hazards The draft SEP Topic VI-8 evaluation cited above concluded the following with regard to radiological protection afforded by the Ginna control room design:

"Although the margin of protection to operators for recently licensed plants is required to be

greater, the Ginna control room habitability design provides substantial protection to the operators in the event of accidents involving radiological releases from the plant by isolation and recirculation.

The design assures

that, except under rarely occurring meteorological conditions in coincidence with accidental radioactive releases that are unlikely to occur even in the event of a Design Basis Accident, the operators wil not receive excessive doses.

Highly unlikely events involving sequences of postuated successive failures more severe than those postulated for the design basis could potentially result in severe exposures to control room operators,

however, the probability of this occurrence is so low that.

they are not considered in the design of nuclear power plants.

In view of the substantial level of protection provided to the control room operators and the low probability of excessive exposures to the operators, we conclude that, it is not mandatory to take any immediate measures to provide additional protection to the operators."

The control room radiological hazards evaluation performed by Rochester Gas and Electric has also confirmed that the current system and structural design provides consider-able operator protection from direct radiation and airborne radioactivity.

Nevertheless, in view of current design requirements, such as Standard Review Plan 6.4, it has been deemed appropriate to consider system modifications to assure that post-accident operator doses will be maintained at. acceptable levels.

Specifically, we have proposed a modification concept to:

10

'l I

l)

Provide a more rapid post-accident detection capability prior to the buildup of significant radioactivity levels inside the Ginna control room.

This will be achieved by the installation of a detection system in closer proximity to the control building ventilation intake, with automatic isolation capability; 2)

Limit. the maximum intake rate of outside air in order to ensure adequate damper isolation time in the event of a high radiation signal.

This will require the installation of a new, smaller-sized damper placed at an appropriate distance from the post-accident radiation detector location.

It is expected that these modifications can be completed by July 1, l983.

5.2 Onsite Chemical Hazards The NRC draft evaluation for SEP Topic VI-8 identified the onsite 500-gallon anhydrous ammonia tank as a potentially significant impediment to control room habitability.

The SEP draft evaluation concluded:

"We believe minimum impact on the licensee would result by the installation of ammonia detectors in the control room intake or a detection devices

[sicj at the tank to alarm ammonia release, and alert the operators to don self-contained breathing apparatus.

The need for additional improvements, such as closure of the control room inlet dampers on high ammonia concentration in the inlet ducts or upon a tank failure signal, a collection system for accidentally released ammonia (water adsorption or a containment around the tank), or relocation of the tank, should be determined dur'..c the integrated safety assessment for Ginna."

We concur with the identified need to provide for ammonia detection capability, and to investigate other means to further reduce potentially excessive control room ammonia concentrations.

Accordingly, the following are planned to address this issue:

l)

Installation of an ammonia sensor system for the rapid detection of high ammonia releases in proximity to the control room ventilation intake or the outside storage tank;

r.

1 '}

2)

Provide automatic isolation capability of the control building ventilation system in the presence of high ammonia concentration; 3)

Investigation of additional measures to reduce the anhydrous ammonia hazard.

Such options include additional atmospheric diffusion analysis, control room in-leakage verification, chemical substitution, tank enclosure or tank relocation.'t is anticipated that the above modifications (1 and

2) can be completed by July 1, 1983.

The investigation of optional measures to further reduce ammonia hazards will be completed by July 1, 1982.

5. 3 Offsite Chemical Hazards Due to the potentially significant chlorine concentrations resulting from a postulated tank rupture at the 1.1-mile distant Ontario water treatment plant, a need for the following modifications has been identified:

1)

Provide a chlorine sensor system for the rapid detection of high chlorine concentrations outside the control building ventilation system intake; 2)

-Provide the capability to automatically isolate the control building ventilation system upon detection of high chlorine concentration.

These modifications are expected to be completed.by July 1, 1983.

5.4 Additional Investigations Other areas pertinent to the issue of control room habit-ability have been identified which we conclude warrant, further investigation.

1)

A modification has been initiated to alter a portion of the control building ventilation/filtration ductwork in order to provide added assurance that adequate system return air is directed through the HHPA and charcoal filter unit in the post-accident operation mode.

This modification is presently scheduled for completion during the 1982 refueling outage.

2)

He will also investigate whether proper residence time is being maintained in the control building charcoal filter banks and propose corrective measures if needed.

This investigation will be completed by July 1, 1982.

12

to Attachment 2

Information Required for Control Room Habitability Evaluation NUREG-0737 Topic III.D.3.4 R.

E. Ginna Nuclear Power Plant

I it I

~"i

Appendix A to Attachment 2

Information Re uired for Control Room Habitabilit Evaluation HUREG-0737 III.D.3.4 Control Room Node of Operation The following is the information requested in Attachment 1 to NUREG-0737, Item III.D.3.4.

The control room atmosphere is filtered, heated and cooled as required by a separate ventilation system.

This system circulates air from the control room, control room office and kitchen, and computer room through return air duct work to a central air conditioning unit located adjacent to the battery room.

The air is drawn into the unit through roughing type filters, and either heatd or cooled as required by steam heating or chilled water coils.

Conditioned air is directed back to the rooms through a supply air ductwork system.

Room air turnover rates provided by this system are approximately as follows:

Control room Office and kitchen Computer room 20 per hour 10 per hour 36 per hour During normal operation fresh makeup air is admitted to this system through an intake louver located above the control building ceiling, the amount varying between 15 and 100 percent of the unit flow rate, depending on outside air temperature.

Pneumatically operated dampers can be positioned from the control room to isolate the fresh air intake and to place a separate charcoal filter unit in service.

The charcoal filter unit includes both high efficiency particulate air (HEPA) and charcoal filters for removing radioactive particulates from the control room atmosphere.

In the event of high radiation levels in the control room, the control room radiation monitor (set at 2 mR/hr) will automatically close the dampers in the fresh air intake duct and in the return air duct to the Turbine Building and will open the damper in the charcoal filter unit inlet duct.

This signal will also start a separate fan to provide flow through the charcoal filter unit.

Until radioactivity in the control room atmosphere is reduced to a safe level, system flow will be in a closed cycle from the control room, with a portion of bypass flow (assumed to be 2048 cfm in this analysis) through the charcoal filter unit, through the air conditioning unit and back to the control room.

The dampers can 14

~

also be positioned to permit fresh air makeup to the system through the charcoal filter unit.

Since all control room penetrations, including doors, are designed to high leak tightness standards and the control room is maintained at essentially atmospheric

pressure, the infiltration of contaminated air into the control room is limited to a very low rate (assumed to be 0.06 hr 1

in this evaluation).

(2)

Control Room Characteristics (a)

Volume Control Room:

Computer Room:

Equipment Room:

39,520 ft3 6,264 ft3 15,382 ft3 (b)

Control Room Emer enc Zone 1)

Control room emergency zone with pressurization will consist of the control room, computer

room, and the equipment room.

2)

Control room emergency zone without pressurization will consist of the control and computer rooms.

(c)

Ventilation S stem Schematic Refer to Figure A-1 enclosed.

(d)

Infiltration Leaka e Rate The infiltration leakage rate has been assumed to be based upon 0.06 volume changes per hour (45.8 cfm) without pressurization.

(e)

Assumed Charcoal Filter Efficienc Containment recirculation filters (for iodine) elemental 905 organic 70%

particulate 90%

Control room, re circulation 90% for all species (f)

Distance Between Containment and Air Intake Approximately 100 ft.'5

=P 4I

La out of Control Room, Air Intake, Containment Buildin,

and Chlorine, or Other Chemical Stora e

Facilit with Dimensions Refer to enclosed figures in Appendix B.

Control Room Shieldin The Control Room is shielded with 20-inch concrete south and west walls and ceiling, facing the Containment Building.

There is no door facing the Containment Building, and no radiation streaming is expected through any penetrations between Containment and the Control Room.

The Control Room north and east walls consist of 1/4-inch armor plate and steel siding.

Automatic Isolation Ca abilit Darn er Closin

Time, Dam er Leaka e and Area 30 seconds is assumed for radiation detection and damper closure.

Toxic Gas Detectors None presently are installed to operate in conjunction with the Control Room ventilation system.

Self-Contained Breathin A

aratus There are two Scott Air-Paks and 2 bottles inside the Control Room; and four additional Scott Air-Pak units with 8 bottles located immediately outside.

Bottled Air Su 1

The Control Room is provided with two 300 ft cylin-ders.

Two additional 300 ft cylinders are located outside the Control Room.

Emer enc Food and Potable Mater Su 1

The Control Room is provided with a kitchen having potable water and food supplies.

A freezer containing a supply of TV dinners and other food items is main-tained in the kitchen, and an additional food freezer is located immediately outside the Control Room.

The SEP draft evaluation of SEP Topic VI-8 "Control Room Habitability" (January 19, 1981) concluded the Ginna Control Room "to be capable of maintaining an emergency team (at least 5 men) for at least 5 days, satisfying the guidelines of the SRP 6.4."

16

(n)

Control Room Personnel Ca acit (Normal and Emer enc

)

Normal 3 individuals Emergency 5-8 individuals (o)

Potassium Iodine Dru Su 1

A supply of approximately 150 KI tablets is maintained in the Control Room.

Additional KI tablets are available on site.

17

xURE A l CONTROL BUILDING VENTILATI DIAQRAI'i OW A

CONTROL ROOIC AIR HANDLING UNIT O

IX SUPPLY FAN CGNTROL RGGbi CONTROL ROCV. DAYPER POSITIONS CONDITION DAMPER POSITION NORMAL POST-ACCIDENT N/i<lIN.

OUTSIDE AIR POST-ACCIDENT M/Ofo OUTSIDE AIR

$1,2&3 CLOSED, f142 OPEN.g3 CLOSED.

"A" CLOSED IIBIlgIICII 75fo OPEN,

$ 28t:g OPEN, g1 CLOSED. "A".&"C" CLOSED."B" OPEiN.

RELIEF AIR RETURN AIR FAN

to Attachment 2

Onsite Toxic Chemical Survey R.

E. Ginna Nuclear Power Plant Control Room Habitability Study

SODIUH HYPOCHLORITE:

APPROX.

10,000 GAL.

tUNDERGROUND)

SGRESH HOUSS 0

r Hri Ot.

OGSO.

STOR

%M SNG tttOG.

tr DL

+NO tkel

+;

ANHYDROUS AMHONIAt 500 GAL.

AVT tulsa 8

TSO tHTSRIISatATE Gt.OG.

CONTROI. BLDG. VENT INTAKE NITROGEN: 48 BOTTLES LIQUID NITROGEN: APPROX.

250 GAL HYDROGEN: 21 BOTTLES INSIDE ENCLOSURE CONTROL BLDG. VENT INTAKE T

ttt I

I SOUtH SLEV4TOH

QI

~ I ~

i)YDROGEN) 55 BOTTLES CARBON DIOXIDE: 21 BOTTLES ACETYLENE:

1 0 BOTTLES FREON:

2 BOTTLES PROPANE) 5 BOTTLES lpga MET))ANE IN ARGON:

2 BOTTLES NETHANE) 2 BOTTLES NITROGEN:

9 BOTTI ES ARGON:

1 BOTTLE l

I

>>I NITROGEN:

5 BOTTLES

~ >>Ir Ts.

~ I

~ I

~ )

<~ T-6'>>~

~

(E

'- 3 I-",I

)

R C

IIII 4

I ~

~ ~

~ ~

~ II

~ ~

~~ I I

l'i;-

I I I I I

I

~

t

. i(T'.'.

~

~ I )

I J

~.

66 S

I ~

)'

!c 6

R ~

>> C 6

)-= '0 IN'r'g I

'SA t'J j

I!.,!I.

~0

~ I ~ ITRR I:.-

I>>

- ).-J

'I I

I I

~

~ 6

~S QR.

1; L

6).,

span i

NITROGEN: I SOTTLEI E

i

CI I

IIi

~ I

~

IR II gS

~ ls,s I ~

~ 6 6

IIIII JR

)I B)I I

I>>

I IR )

6)>>

s' I

~

,'gss w ~

il)i I )TI)c

~ ~

16,s) I I

-~--

's

'I I

~

fl,.

I

.:)

~

I

~ )

'LS~R-S "I~

'- Ei

~

~

...!)'r I

'I

~

6 J:

~ S fl ii;

.Ii

)~I I I'kl6 6

-~"

'I I

A 6 ~ I

~LT..Lj 6P00 GAL 98%

H2SO4

..16 I

.i, o

/ >>

I

'RlI

~ I I ~ss

~ ~

~ I I,'I

-IJ RO I ~

~

~

I I

.I,

~ I

- )QA 6000 GAL ~

gpss NaOH 6

Qo ARGON:

15 BOTTLES OXYGEN: 13 BOTTLES N~ A i.Q I

V 1

6 ws A&6 V A

A 6

'C r

A)ATER TREATt)ENT ROON 6000 GAL. 50'L NaOH 6000 GAL.

98% H2SC4 A

FIG. B-2 TURBINE BUILDING PLAN. ABOVE BASEMENT FLOOR ELEV. 253'-6"

5% N2H4.

50 GAL.

35t N2H4 s 1

35 RUM

~

~

e~~

I~is J,e vtdlsstwss' o

15% NH40H:

APPROX.

50 GAL.

r Segi e

s,f. t'i HYDROGENs 1 BOTTLE CARBON DIOXIDE:

1 BOTTLE 30K NH4OH:

1 55-GAL.

DRUM 30%

NH OH:

10 55-GAL.

DRUIIS 4

r ie se l)] )ii j Qo l~

I e

are v e

~emHP eave v"

!par a

S~

evee cB ANSUL 1301 FIRE CONTROL AGENT BROMOTRIFLUOROMETHANEs*

8 TANKS 9 160 LB.

.iQ J

~

~

e ~

a s

a

~e ee

~

ace

\\Ij f'

.W' ar er ie a ~aw re

\\

~i

~

FIG.

B 3

TURBINE BUILDING PLAN ABOVE MEZZANINE FLOOR ELEV. 271'-0"

COI Cll CO a ~ l I

0 V

q1

)!

po

],i (

r 00 QZ kl Oc.0 0

R QR 6

fd m 5l

)!

~\\

AV

~ JVI JH4' l

I

~

I

~ I I,

1

, Q4wJ!

)h

~f I'll If'N If~

C9 CCO M

23

A endix C

to Attachment 2

Offsite Toxic Chemical Survey R.

E. Ginna Nuclear Power Plant Control Room Habitability Study

PROCEDURE FOR DETERMINING TOXIC CHEMICALS WITHIN A FIVE MILE RADIUS OF THE R. E.

GINNA NUCLEAR PLANI'.

~Ob ective The purpose of this survey is to establish type, location and quantity of toxic chemicals at industrial, transportation, or military facilities within a five mile radius of the plant site.

In particular, we are interested in those that interfere with the operator's ability to carry out their duties if they were released into the atmosphere.

RG5E may also find it worthwhile to look for explosives as part of this survey.

h B.

Toxic Chemicals The large number of chemicals which could pose a threat to the operators makes it impossible to conveniently list all of them.

Furthermore, deter-mining the minimum quantity of a toxic chemical that has to be evaluated depends on the location and the particular chemical.

For most chemicals potentially hazardous quantities range from 100 pounds at distances of less than one mile to 60,000 pounds at four miles.

However, for some highly toxic chemicals such as fluorine, quantities may be as low as 8

and 4,.800 pounds respectively.

Important quantities of toxic chemicals would cause severe health hazards local to any accident involving them.

Therefore, government authorities and the users will be aware of the location of these chemicals.

(However, it may be difficult to find the particular person or agency who knows.)

Any chemical, held in large enough quantity so that evacuation of the accident site would be required, is of interest to the survey.

Attachment A lists some chemicals that the NRC has found to be important.

25

~hd Completing this survey will.require some detective work to identify potential users or carriers of toxic chemicals and some persistence to obtain the desired information.

These steps should be followed during the survey:

I) Using maps such as those available from the U.S. Geological Survey (USGS), identify the major transportation routes within five miles of the plant.

For Ginna, this would include Route 104, the railroad spur that runs parallel to it, and Lake Ontario.

Some USGS maps also include the location of major industrial facilities.

2) Contact federal, state, and local agencies responsible for public transportation and safety.

First, contact should be by phone to assure that the proper individual is being approached (this will take some effort) and to obtain an agreement to re-spond.

(Remember that these agencies may not be obligated to respond.)

Once the correct person (normally the word safety will be in their title) has been contacted, he should be informed of the problem and told that you will be sending him a letter requesting any information that he may have on the subject.

To expedite the survey, inquire about any information that he may be able to give over the phone, including other contacts.

Records should be kept of all contacts.

3) Based on RGgE's knowledge of the area, contact companies which may store toxic chemicals or transport them within five miles of the site, use the same procedure as in Step 2.
4) Based on these initial contacts, other leads should develop.

These should be followed up in the same manner as Step 2 also.

Sample correspondence is contained in Attachment B.

Suggested contacts to make are in Attachment C.

- 26

Specifically, the information required about chemicals stored in the area is the number of containers, their size, and their location with respect to the site.

The latter should be marked on an approp-riate map (USGS).

For chemicals in transit, we require the chemical's

name, the frequency of shipment (in truckloads, rail cars, or barges per year),

and the size of the load.

27

AT1'ACFÃEN1' Some Toxic Chemicals I ortant, to Past Studies Acetaldehyde Acetone Acrylonitrile Anhydrous ammonia Aniline Benzene Butadiene Butenes Carbon dioxide Carbon monoxide Chlorine Ethyl chloride Ethyl ether Ethylene dichloride Ethylene oxide Fluorine Formaldehyde Helium Hydrogen cyanide Hydogen sulphide Methanol Nitrogen I'compressed or liquified)

Sodium oxide Sulfur dioxide Sulfuric acid Vinyl chloride Xylene 28

ATTAC1RENT B S

le Letter Rochester Gas and Electric.has received an inquiry from the Nuclear Regulatory Commission regarding the storage or transport of hazardous materials in the area near the Robert E. Ginna Nuclear Power Plant site.

As I mentioned in our phone conversation of

, we are interested in quantities of hazardous materials within a five mile radius of the Ginna site, which in an accident situation could require an evacuation.

The toxic chemicals of primary concern to us are gases such as chlorine, anhydrous

ammonia, and fluorine.

Some liquids such as sulfuric acid and xylene can also be of concern.

I have attached a map illustrating the area of concern to us around the Ginna site.

Notice that Lake Ontario, Route 104, and a rail spur are all within this area and may carry hazardous chemicals.

The information that we require for toxic chemicals stored near the site is:

-the chemical's

name,

-the location,

-the number of containers, and

-their size.

For chemicals in transit, we require:

-the chemical's name

-the frequency of shipment

( truckload, rail cars, or barges per year),

and

-the size of the shipments.

If you have any questions or need assistance, please contact I very much appreciate any attention you can give this request.

- 29

ATI'ACRKfZ C Su ested Contacts A.

U.S..Government 1.

U.S. Department of Transportation

a. Coast Guard U.S. Court House and Federal Building, Syracuse, (315) 423-5674 700 7th Street, SN, Washington, DC 20590 (202) 426-1587
b. Federal Highway Administration Director of Motor Carrier Safety N. F. O'rien Federal Building, Albany (518) 472-7509 400 7th St.,

SÃ, Washington, DC 20590 (202) 426-0648

c. Federal Railroad Administration U.S. Post OHice and Court House, Albany (518) 472-2272
2. National Transportation Safety Board Bureau of Accident Investigation 800 Independence Drive, SI Washington, DC 20591 (202) 426-8787 B.

New York State Government

1. Division of Military and Naval Affairs Public Security Building Campus, Albany
a. Emergency Planning OHice (518) 457-2323
b. Office of Natural Disaster and Civil Defense (518) 457-2222 2.

New York Department of Transportation

a. State Campus Administration and Engineering Building, Albany OHice of Engineering, TraHic, and Safety Division (518) 457-6438 b.

1530 JeHerson Road, Rochester 442-8580 C.

Local Government

1. Fire Department
2. Police Department
3. City and County Governments 30

D.

Local Companies E.

Independent Organizations

l. American Trucking Association (for information on local trucking companies) 1616 P St., Nf Washington, DC 20036 (202) 797-S241 31

OI)10 ~)0 Lake

~

r ('

Ontario t.'ater Treatplent Plant FOUR MILE THREE MlI. E IIIIIIII ego TWO Mll E ONE Mll E L AKE.

PINNA Sl TE ROlaeaxa ~x

>n e: e

~

~

" r0 1930 August 21, 1981 100 SUNNY SOL BLVD.

~

CALEDONIA, NY 14423 Telephone:

(71 6) 538 231 1 PLANTS:

Barberton, Ohio Beech Grove, Ind.

Caledonia. N.Y.

Charlotte, N,C.

Erie, Penna.

Festus, Mo.

Ft. Lauderdale. Fla.

Henderson, Nev.

Houston, Texas Hudson, Wis.

Jacksonville, Fls.

Merrimack. N,H.

Milford,Virgmis Milpitas Cabl Mobile, Alabama New Orleans, La.

(Reserve. La.l San Oiego, Cabf, St. Petersburg, Fls.

Tacoma, Wash, Torrance Calil Warwick, N,Y.

Wyandotte, Mich.

Rochester Gas 6 Electric 89 East Ave.

Rochester, NY 1 0 64 9 Attention:

June Horning

Dear Mrs ~ Horning:

Enclosed is the map show'g the routes travelled by JCI trucks in delivering to Girma Nuclear Power P 1ant and Ontario Water Treatment Plant.

We do not de 1iver chlorine to the Ginrna Plant.

We do deliver approximately 1 ton container of chlorine per month to Ontario Mater Treatment Plant.

The truck might have a total of 6 to 8 tons chlorine maximum on board.

I trust this is the in'rmat ion you require

~

Sincerely, JONES CHEId NC ~

~

~

xvan National Saf ety Director JHS / 1mb 34

]ONES A

GOOD NAME IN CHEMICALS

FOUR MILE THREE MiI. E TWO Mil E, gfI(argo Lake ONE Mllc G INNA SiTE RO/lA SOI' GIHHA Si'I'I':

0 0 g'~S pgc 0

c, BOSTON 80 ROAD L AKE.

O K

0R 0

BRICK 7

ng CHURCH R PUT NAM ROAD I

SHEPHERD RD LEY RD LLJ 0

cn laj I

I 0

00 4lZ j

BERG ROAD 0

Vl WY z

KENYON z

ROAL L'j Vl 4.

I

/

D0U PENN

-l--.-.

CENTRAL R R C..

RID E

0 0

N Y A R

t 0

STATC I I

WAY ROUTE O

,3 PADDY J

LANEO WHITNEY ROAD wAI.w R rii (i1

) 5 <<vg

/ (Oh+<<o &Wc 10/74

Hazardous Chemical Survey Town of Ontario Water Utilities:

Chlorine July 2, 1981 Town of Ontario Mater Utilities Dept.

2200 Lake Road

Ontario, New York 14519 Jack C. Haywood, Superintendent Nike Ralston, Operator (524-2941)

Nike IIalcomb, Operator (524-8520)

The town of Ontario operates two water treatment facilities:

A.

Wastewater treatment plant and a lake water treatment plant.

The former is locatd on Lake Road, 1.5 miles east of Ginna, the later is 1 mile east on Lake Road also.

Both store pressurized tanks of chlorine on site.

The lake water treatment plant stores chlorine in two 2000 lb. cylinders housed in a separate chlorine building.

These tanks are side by side, individuality connected to the main system via an aluminum tube with an outer diameter of approximately 1/2 inch.

Only one tank is in use at any time: the other is shut off with a valve at the tank mouth.

From the 1/2 inch feedline, the chlorine is dissolved into a 1 1/4 inch water line (outside diameter) which leads to the main building; it is a distance of 75 feet.

Chlorine, polymers and alum are added to the raw lake water in the main building. It then enters a flash mixer and charifier.

The entire system is computerized with self adjusting automatic feed.

Chlorine is used at an average rate of 70 lbs/day with one of the cylinders kept in reserve, and the other refilled monthly.

LAKE WATER TREATNENT PLANT FLOW CHART:

Town Flash Mixer Chlorine Building 1/4" Feed Line; 75 Feet Clarifier Raw Lake Mater 16" Diame ter Pipe 36

Information on the Lake Mater Treat;ment Plant was obtained from Ron Reyse, a

terrporary operator while Nike Nalcomb is on vaction.

Further questions should be directed toward Nr. Nalcomb afCer 7/7/81.

The wastewater treatment facility stores chlorine in 150 lb cylinders, housed in a chlorine room which is part of the administrative building and laboratory.

Five to six full tanks are delivered monthly.

Two of these tanks are hooked up to Che system at the same time, one is shut; off at t;he tank water.

Feom Che chlorine room, the chlorine travels approximately 300 feet through underground piping to the retention tank.

Here the chlorine is bubbled into the wastewater.

Underground piping for chlorine also leads to the entrance structure and the aerobic digestor, but it is not currently used.

This information was obtained from Nike Ralston, Operator.

Questions should be directed Coward Jack Haywood, Superintendent;.

37

e rf

~ g Il I

I lil I

I

~

I I

t I

~

a I

I

~

~

I I

e rl

~ I )

I

~

I I.

I I

c EXTENOEO AEBATION I

TOWN OF ONTARIO WATER UTILITIES DEPRIITNEN1 WASTEWATER TRE,ATHEIST FAClLITIES SchevFIDTHc; Flow Dlaqrarrt Potortcsd EIIterre

~ s

WI4e, Oe'nsl Ctseoet AEKATlotl tANK No. I r

~

AEWATION IAtlKNo.t AAS D Seeerrretorrt Tdtt Dot PAELIMINABY TAEATtdEtlT hetot Itcred WI4 I

I Corsrrdeefer

~NIIIIIIIIIIII C4CII~IIII~III~IIIIIIIII~

Ftorr Mcterteo FtseSeccercro tNTKANCESTNVCTIKIE IJAOI FtttJP SIAIIOII

~IIIIINII

~IIINIIIIIIIJIIII

~I ~III~INII I~IIIIII

~ II~I ~

I we> Wen (Nrwedl J,;t wosre Ssrdee SLUM FVW'LDO SLUDGE IIOLTKIJTTANK.

AEIKKKCTKCES TEN 0 0 0 ris FINAL St T TLIIIO TAIIKMat AEBOOIC OIOESTTON 1

Dreecled Sled et torord lo Itrrcd

~

rnstrosel site

~F'ledle Well J

FIIIAL SETILIIIO TAtrKNo. I Leo ~Ild, Q

FVtltr ~

I~ I~I~ II~

FOACEP CKAYITT

~

~

altMICAL INFLUENT Ellteerd

~

Weir Treeeoe 4

Seers Doc J

Ftoo Dtstrleolleo MIL

~0 SECONOAB'Y-SETTLINO TENTIAhfFILThATIOtlDLDO.

O--

Med 'ifcll Cene

,i <--

1 E

9 Clear well Ltttserd Mcrerho TEATIAAY FILTAATIOtl T CNLonott CotlTACT ~

TANK tto I T

A J

EFFLVtNT AENATIOtl TAIIKtlo. I I

AclvIIelle Etlteerd cecilI EFFLUENT

~r rc rr pc ~J

~tttteerd.pc4 Trovlls Erst Wetl EFFLIICtlt ATNAIIotl TAtO( Mat cttLonwtt CONTAC'I TAtlKtlo.T ClILOAINATIOtl 6 EFFLUENF AEAATIOtl

t ~

j, ~

tN ltyO DEPARTMENT OF TRANSPORTATlON MAILINGADDRESS:

UNITED STATES COAST GUARD Commanding Officer USCG MARINE SAFETY OFFICE

'e Bldg.,

Rm 1111 111 Nest Huron Street

'Buffalo, New York 14202 Ms. June Horning Rochester Gas 5 Electric Corp.

89 East Avenue Rochester, NY 14649

Dear Ms. Horning:

16450 24 July 1981 In response to your letter of 21 July 1981, this office does not maintain records of the information you requested.

Sincerely THERON A. PATRICK Lieutenant Commander U. S. Coast Guard By direction of the Commanding Officer 39

IC>?i DEPARTMENT OF TRANSPORTATION MAILINGADDRESS:

UNITED STATES COAST GUARD Officer In Charge Coast Guard Station exodus Point,NY 14555 Z3 August 1981 Rochest,er Gas And Electric 89 East Avenue Rochesteri NY 14649 Dear hiss Horning After being inintact with my command I'e found that we have no records of any disposal or waste sites in the area, I apologize for the time delay but summer schedules are quite busy. If I may be of further assistance please contact my office, Sincerel w/g 7 M.Go PARKER BM1 U+Se COAST GUARD Officer In Charge 40

PQ(j Q QIFIlg/f pKlooll 3 I

~ L fu~~~ rw~ ri~ i~~II ".m

"'1'I 'IF PLI"'R 3 AVAILABLEFROM BUSINESS ENVELOPE MANUFACTURERS, INC.

PEARL RIVER, N Y. ~ BRONX, N Y. ~ CLINTOM,TENN.

MELROSE PARK. ILL ~ ANAHEIM,CALIF.

June Horning Roc es er as 8

East Avenue Roc es er, ew ec rz.c orpora won or BARKER CHEMICAL CORPORATION P. 0, BOX 1S6

'LTON, NEW YORK 14413

-T, DATE: ~g ~,~i~

FULO ~

In re ards to the attached letter which we received from ou we do not handle an chemicals which would fit into the discri tions ou ave.

What we do handle is low-rade a ricultural chemicals (non toxic)

If I'an be of more assistance, please feel free to contact me at the above address.

PLEASE REPLY TO p SIGNED:

SIGNED:

K, bO P~Il QR AVAILABLEFROM BUSINESS ENVELOPE MANUFACTURERS. INC. ~ PEARL RIVER, M.Y. ~ BRONX. N.Y. ~ CLINTOM,TENN. ~ MELROSE PARK, ILL.~ AMAHEILI,CALIF.

LoT EI 57456B

Xerox Corporation Joseph C. Wilson Center for Technology Rochester, New York 14644 XEROX 3uly 29, 1981 Ms. 3une Horning Rochester Gas R Electric Corporation 89 East Avenue Rochester, NY 10609

Dear Ms. Horning:

This memo is in response to your request for information on Xerox storage or transportation of hazardous chemicals within a five mile radius of Ginna Nuclear Power Plant.

Please be advised that Xerox does not currently store or transport hazardous chemicals within the specified five mile radius.

If you require any additional information on this subject, please do not hesitate to contact me.

Yours truly, ames F. O'rien Manager, Operations Safety Corporate Environmental Health and Safety dc c:

3. MacKenzie 42

i

AGCH.EM SERVICE CORP.

P.O. BOX 7 SODUS, NEW YORK -14551 AREA CODE 315-483-9146 July 29, 1981 Hs. June Horning Rochester Gas

& Electric Corp.

89 East Avenue Rochester, View York 14649

Dear Ms. Horning:

In response to your letter of July 21, 1981 I will try to help you, as much as I am able to.

Fruit growers in the area store small quantities of agri-cultural chemicals for short periods of time.

Economic con-ditions necessitate accurate planning and purchasing of agri-cultural chemicals thereby eliminating any inventories of hazardous chemicals on the farm.

Most farmers today buy only what they need for an individual spray application and it is normally used within a day or two of purchase.

These materials would be stored in a properly constructed and placarded building used specifically for spray materials.

The names of these chemicals are:

Guthion(Azinphos Methyl)

Vydate L(Oxyaml)

Lannate (Methomyl)

Monitor(Methamidophos)

Parathion Furadan(Carbofuran)

Temik (Aldicarb)

Systov(Demeton) 12/23.N/cas e 1 gal.

5 gal.

cans 1 gal.

& 5 gal.

cans 2 gal.

5 gal.

cans 5 gal.

cans 50Pr bags

& 1 gal. con-tainer 30>4 bags 2 gal.

cans Quantities would be next to impossible to estimate.

Chemicals in transit would be primarily for delivery to local distribution firms.

I would estimate that not over 50 truckloads of hazardous agricultural chemicals would pass on the designated highways per year.

The list would be the same as the above list.

There would be several hundred shipments of less than AGCHEM

truck load quantities of.these materials for delivery to farms and local distributors ranging in size from 1 gallon to several pallets.'

trust this is the information you require and I regret that I cannot supply you with more accurate quantities.

Yours truly, AGCHEN SERVICE CORPORATION WRY: sd William R.

andrich, Jr.

General Manager 44

ROCHESTER GAS AND ELECTRIC CORPORATION INTEROPPICE CORRESPONDENCE August 18, 1981

SUBJECT:

Visit to Ontario A wa

Store, Au ust 18, 1981 Toxic Chemical Surve TO:

File Today I met with 6lr.

Roy Hermann, owner of the Ontario Agway store located approximately 3.7 miles southeast of Ginna Station, near the corner of Furnace Road and Route 104.

I was shown the following materials found on the premises:

Item A

rox. Quantit Various pesticides (Parathion,.

Guthion, Vidate, Nudrin, Paraquat, Disyston) 1-2 cases Shrub sprays (containing 50'4 xylene or aromatic petroleum deriv. solvent) less than 3 gal.

Liquid chlorine for swimming pools 30-40 4-gallon cases NITAN (32% nitrogen in solution; of which 50% urea, 50% ammonium ni"rate).

4,000 gal.

These inventories were considered typical of those quantities in stock for this season of the year.

+ g~,/ J, vs+

Ricnard J.

$7a tts 45