Notification of 820430 Meeting W/Util in Bethesda,Md to Discuss Current Status of Steam Generator Repair & Other Items Pertinent to Restart
ML17256A891
Person / Time
Site: Ginna 
Issue date: 04/28/1982
From: Lyons J
Office of Nuclear Reactor Regulation
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
NUDOCS 8205100201
Download: ML17256A891 (4)


Text

April 28, 1982 Docket No. 50-244 MEMORANDUM FOR:

Dennis M. Crutchfield, Chief Operating Reactors Branch 85, DL

~~ceveo, s

M~Y3 t982u 8 MM~9u>g gag~

E&fNkeeygg g TIOC FROM:

SUBJECT:

James E. Lyons, Pro)ect Manager Operating Reactors Branch 05, DL FORTHCOMING MEETING IIITH ROCHESTER GAS 5 ELECTRIC CORP.

Date 5 Time:

Location:

Purpose:

Participants:

'Friday April 30, 1982 9:00 AM P-118 Phillips Building The purpose of this meeting is to provide a current status of the repairs of the Ginna steam generators and to discuss other items pertinent to the restart of Ginna.

NRC D. Eisenhut, R. Mattson, R. Vollmer, J. Lyons, et al.

RGSE J. Maier, et al.

Original signed by James E. Lyons, Project Manager Operating Reactors Branch 85 Division of Licensing

~ 8205100201 820428

[, PDR ADOCK 05000244

-P PDR OFFICE/

SURNAME/

DATE Q DL; B

A'5

~ ~ \\ ~ ~

~

~ 0 ~

~

~ ~

~ 0 JLp ns:cc q-g.S yO

~ ~

~ ~ ~ 0 ~ ~ ~ 0 ~ 0 ~ ~ 01 ~ 0 ~ JIO ~

NRC FORM 318 tIO-80) NRCM 0240 OFF ICIAI RECORD COPY USGPO: 198 I~960

~e

~r l

~

\\

  • II

hlEETING NOTICE DISTRIBUTION Docket NRC PDR Local PDR ORB Reading NSIC DCrutchfield HSmith JLyons OELD OI3IE ACRS (10)

SEPB SUarga DVassallo RClark JStolz DEisenhut INattson RVollmer HSchaaf Receptionist (Phillips Building)

RA RI RCaplan FLevin BPollard OFFICE/

. ~. ~ ~. ~. ~

SURNAME$

~ ~. ~ ~ ~ ~ ~.

DATE %

NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USOPO: 1991~i960

0