ML17256A546

From kanterella
Jump to navigation Jump to search
Summarizes Activities Required to Resolve NUREG-0737,Item III.D.3.4, Control Room Habitability, Requested in NRC .Redundant Dampers Will Be Installed in Control Room Intake & Exhaust Ducts Direct to Atmosphere
ML17256A546
Person / Time
Site: Ginna 
Issue date: 03/07/1983
From: Maier J
ROCHESTER GAS & ELECTRIC CORP.
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-3.D.3.4, TASK-TM NUDOCS 8303110338
Download: ML17256A546 (4)


Text

~

w<<

REGULATOR NFORMATION DISTRIBUTION S EM (RIDS)

AOCESSION NBR;8303110338 DOC ~ DATE! 83/03/07 NOTARIZED:

NO DOCKET FACIL:.50 '244 Rober,t Emmet Ginna Nuclear Plantr Unit ir Rochester G

05000244

'AUTH INANE AUTHOR AfFILIATION MAIERrJ ~ E ~

Rochester Gas 8 'El ectri c Corp,

'REC IP ~ NAME RECIPIENT AFFILIATION ORUTCHFIELDiD<

Operating Reactor s Branch.5

SUBJECT:

"Summarizes activi,ties requir<<ed to rTesolve NUREG-0737'tem III.D,3.4r "Control Room Habitabilityrr<<equested in NRC 821018 l'tr,Redundant damperTs will installed in control room intake 8 exhaust ducts dinect to atmosphere.

OISTRIBUTION:COOE: 'AOASS COPIES RECEIVES:LTR.I ENCL.3 SIZE:..

,TITLE: 'OR Submittal':

>TMI Action Plan 'Rgmt NUREG-0737 L NUREG-0660" '

NOTES:NRR/DL/SEP icy, 05000244 RECIPIENT ID CODE/NAME NRR ORB5 'BC 01 INTERNAL: <<ELD/HDS4

  • IE/DEP EPOS NRR PANLSON N ~

NRA/DL DIR 14 NRR/DL/ADSA 17 NRR/DSI/ADRS 27 NRR/DSI/ASB NRR/DST DIR 30 RGN1

,COPIES

. L'"TTR ENCL

'"7 7

1 0

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME IE/DEP D IR 33 IE/DEP/EPLB NRR/DHFS/DEPY29 NRR/DI /ADL 16 NRR/DL/ORAB 18 NRR/DSI/AEB NR I/RA8 04 COPIES L7TR ENCL 1

1

'3 3

1 1

1 1

<<3 3

1 1

1 1

1 1

EXTERNAL: ACRS LPDR NSIC NOTES:

34 03 05 10 10 1

1 1

1 1

1 INPOrJ ~ STARNES NRC PDR 02 NTIS 1

1 1

1 1

1

)TOTAL NUMBER OF <COPIES REQUIRED0 LTTR 44 ENCL 43

<i~T 5

~ xbi>X'0: )'r ~ill. )c)<l

~ P~A 1 fc>>k,Ha'i IlVIc~~ >.>~)'>

a'eao i

0 r>>"'o I

< gs y f0ii~I b<ril'u so>'<w )

f19"ic>>> Ak>'~c!;JIBE'l 10I f AI )I-lych ii<~H)Ul) gf-",Qy')

</T<<l ~1

.ci~ci,).>ref>~f3 8 ev) auf~vrfaol'l

,d,f >>< )I<<

~

ArllTAIJ I -) R)i f I'la I'<I:3 3H

.I">A~i,cf I Q.)

~

rloAf>'l~ ~ Bgol 3(~98 QA F 4t~'loQ<$

gf']JTIIJQ J

>atI yKEVO:43">~av1 ov fool's orb'3ghJl391 gr5 foal'foQ c,95lo'1%6lg; T,lg( kJ

>c,')R~'t nr )io9~oupo~iyg r f I cion l dpi<<oo:l fu~]riv3" ib.c..r). III f Cl'1'trios 0 C 59 f f QPPAf f f foe

'.'iOQ 160 gribbili)098 'l0 f

~ tf <) T'.aA

~ naerfqno~tr')

foes'th

~0oub tgui~6xo 8 o8c'5nl iso<>~

/IIII'////////////

/

1HD iI/I/@@i /////////////

~ ///////N8"'////eu ROCHESTER GAS AND ELECTRIC CORPORATION 89 EAST AVENUE, ROCHESTER, N.Y. 14649

$7AEE JOHN 8, MA!BR Vice Preekient TELEPHONE AREA COOC 7le 546.2700 March 7, 1983 Director of Nuclear Reactor Regulation Attention:

Mr. Dennis M. Crutchfield, Chief Operating Reactors Branch No.

5 U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Control Room Habitability R.

E'. Ginna Nucle'ar Power'lant Docket, No. 50-244

Dear Mr. Crutchfield:

This letter is in response to your letter dated October 18, 1982 and summarizes all activities required to resolve NUREG 0737, Item III.D.3.4, Control Room Habitability.

As requested in your

letter, we will install redundant dampers in the control room intake and exhaust ductwork which have direct access to the atmosphere to ensure that the single failure criterion is met.

Based on availability of engineering and construction

manpower, these and all other activities previously identified to resolve this issue will be completed by July 1, 1984 or one year after the NRC Safety Evaluation on this issue, whichever is later.

Previous regulatory commitments preclude us from earlier completion.

To summarize, the remaining required activities include:

l.

Install new radiation, chlorine and ammonia detectors to automatically isolate the control room ventilation system.

2.

Install redundant dampers.

3 ~

Measure and confirm the acceptability of the residence time in the control charcoal filter.

4 ~

Relocate the ammonia tank currently outside the AVT building.

Very truly yours, J

n E. Maier 8303ii0338"830307" PDR ADOCK 05000244'P PDR It

p

~,,

1

)

y

)

1 ~

1 pp'r