~P,S RE'gI 0
5 g< IgJ, i
.~
0 0 +**++
t UNITEDSTATES t
NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555
'ROCHESTER GAS AND ELECTRIC CORPORATION DOCKET NO. 50-244 R. E.
GINNA NUCLEAR PONE R PLANT AMENDMEHT TO PROYISIOHAL OPERATING LICENSE Amendment Ho.
54 License Ho. OPR-18 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
C.
0.
The application for amendment by Rochester Gas and Electric Corporation (the licensee) dated September 28,
- 1982, complies with the stahdards and requirements of the Atomic Fnergy Act of 1954, as amended (the Act), and the COInIIission's rules and regulations set forth in 10 CFR Chapter I; The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There -s reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public; and (ii) that such activities will be conducted in compliance with the COIIission's regulations; The issuance of this amendment will not be inimical to the common defense and security or to the health
'and safety of the public; and The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
8210180087 821007 PDR ADOCK 05000244
2.
Accordingly, the lice'nse is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C(2) of Provisional Operating License No. DPR-l8 is hereby amended to read as follows:
Techni cal Speci ficati ons The Technical Specifications contained in Appendix A as revised through Amendment No.54, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION
Attachment:
Changes to the Technical
-Specifications Date of Issuance:
October 7,
1982 Dennis M. Crutchfieldhie Operating Reactors Branch 85
. Division of Licensing
ATTACHMENT TO LICENSE AMENDMENT NO.
54 PROVISIONAL OPERATING LICENSE NO. DPR-18 DOCKET NO. 50-244 Revise Appendix A Technical Specifications by removing the page identified below and inserting the enclosed page.'he revised page contains the captioned'amendment number and a marginal line which indicates the area of Mange.
REMOVE 3.6-6 INSERT 3.6-6
PENT.
NO.
'DENTIFICATION/DESCRIPTION ISOLATION BOUNDARY MAXIMUM HAZXMUH XSOLATION XSOLATION (
XSOLATXON TIME +(SEC)
BOUNDARY TIME *(SEC) 203 Contain. Press.
transmitter PT-947 Ec 948 203 Post accident air sample to "B" fan 204 205 206 206 207 207 209 Purge Supply Duct
- Hot leg loop sample Przr. liquid space sample
- "A" S/G sample Przr..Steam space sample "B" S/G sample Reactor Compart..cooling Units A & B 210 Oxygen makeup to A & B recombiners 300 301 303 304 Purge Exhaust Duct Aux. steam supply to containment Aux. steam condensate return "A" Hydrogen. recombiner (pilot and main) 305 305 305 307 Fire Service Hater Radiation Monitors R-ll, R-12 6 R-10A Auto Inlet Xsol.
R-ll, R-12 Sc R-10A Outlet Post Accident air 'sample (containment)
PT 947 PT 948 MV 1563 MV 1566 AOV 5870 AOV 966C AOV 966B AOV 5735 AOV 966A AOV 5736 MV 4758(16)
MV 4635(16)
MV 1080A AOV 5878 HV 6151 HV 6175 HV 1084A MV 1076A AOV 1597 AOV 1599 HV 1554 HV 1557 MV 1560 CV 9229 NA NA NA NA 5
60 60 60 60 60 NA NA NA NA NA NA NA 60 60 NA NA NA NA MV 1819C MV 1819D HV 1565 HV 1568 AOV 5869 MV 956D(14)
HV 9S6E(14)
HV 5733(7)
MV 956F HV S734(7)
(>>)
(11)
SOV IV"2A SOV IV-2B AOV 5879 MV 6165(15)
HV 6152(15)
SOV IV-5A SOV XV-3A HV 1596 AOV 1598 MV 1556 HV 1559 MV 1562 AOV 9227 NA NA NA NA 5
NA NA NA NA NA Normally Closed NA Normally Closed 5
NA NA.'A Normally Closed NA Normally Closed NA 60 NA NA NA (18)