Letter Confirming a 09/25/1972 Conversation Concerning High Flow Switches on the Isolation Condenser Being Out of Calibration - Dresden Unit 3
ML17252B021
Person / Time
Site: Dresden 
(DPR-025)
Issue date: 09/25/1972
From: Worden W
Commonwealth Edison Co
To: Grier B
US Atomic Energy Commission (AEC)
References
Download: ML17252B021 (3)


Text

w I

..t' I

LD001 TOVE MORRIS ILLINOIS SEPTEMBER 25, 1972 10:35AM.

BOYCE GRIER, DIRECTOR DIVISION OF COMPLIANC[

REGION 3 U.S. ATbMIC ENERGY COMMISSION 799 ROOSEVELT ROAD GLEN ELLYN !LLINOIS 60137 SUBJECT DPR-25 DRESDEN NUCLEAR POWER STATION UNIT 3 THIS WILL CONFIRM THE CONVERSATION WITH H. DANCE OF YOUR OFF I GE AT 0915 HOURS TH IS DATE CONCERN !f'.IG HIGH FLO\\!J SWITCHES ON THE ISOLATION CONDENSER BEING OUT OF CAL I BRAT I ON.

mJ 9. 22 72 A FOUT I NE THREE MONTH C/\\L I E3Rl\\ TI mJ

\\tJ.A.S PERFORMED m~ THE H l GH FLOV*.1 ISOLATION SVJ ITCHES.

/\\LL FOUR SV! ITCHES SET PO I ~ns \\riERE FOUND GREP.TER THAil THE LIMIT IN~TABLE 3.2.1. OF THE TECHNICAL SPECIFICATIONS.

THE HIGH STEAM FLOW SWITCHES, DPIS 3-1350 A&B, WERE FOUND SET AT 426.5 AND 435.5 INCHES OF WATER.

THE LIMIT WU 1201 (R 5-69)

WU 1201 (R 5-69)

.. iJ' IN TABLE 3.2.1. CORRESPONDS TO 425 INCHES OF WATEF

  • THE HIGH CONDENSATE FLOW SWITCHES, OPIS 3-1349 A&B.

WERE FOUND SET AT 33.:?1 AND 33.5 INC~ES CF ltJATER.

THE Ll,MIT I ~J Ti\\OLC: 3. 2.1. IN 32 I NCH ES OF WATER.

SWITCHES DPIS 3-1350 A&B WERE RESET TO 416.5 AND 417.5 INCHES OF WATER.

SWITCHES DPIS 3-1349 A&G WERE RESET TO 29.9 ANO 30.1 INCH~S OF WATER.

PRESENT PLAN ARE TO CHANGE THE AS LEFT SETTINGS ON THESE SWITCHES TO A LOWER, VALUE Ai THE Nt:XT CALIBRATION.

\\f.J. P.

~vORDEN, SUPER I t.JTENDENT DRESDEN NUCLEAR POWER STATION

,. ~

i. I

/ !

  • SO-~'+-'/

R B TWX 624 USAEC HQS GTWN WU WSH TLXA226 (47)DEA064 KA2'48 K VEC134 PDF TOVE MORRIS ILL 25 1035A CDT I

EDWARD J BLOCH ACTING DIRECTOR DIRECTORATE OF LICENSING

, US ATOMIC EN.ERGY COMM *WASHDC 20545 SUBJECT DPR-25 DRESDEN NUCLEAR POWER STATION UNIT 3 THIS WILL CONFIRM THE CONVERSATION WITH MR'~ DANCE OF YOUR OFFICE AT 0915 HOURS THIS DATE cdNCERNING HIGH FLOW SWITCHES ON THE ISOLATION.CONDENSER BEING OUT OF bALIBRATION. ON 9/22/72 A ROUTINE THREE MONTH CALIBRATION WAS ~ERFORMED ON THE 1HIGH FLOW ISOLATION SWITCHES. ALL FOUR SWITCHES SET POINDS WERE FOUND.GREA'TER THAN THE LIMIT IN. TABLE 3.2.l OF THE TECHNICAL

. SPECIFICATIONS. THE HIGH STEAM FLOW SWITCHES, DPIS 3-1350 A&B WERE FOUND SET AT 426.5 AND 345.5 INCHES OF WATER. THE LIMIT IN TABLE.3.2.1 CORRESPONDS TO 425 INCHES 'OF WATER. THE HIGH CONDENSATE FLOW SWITCHES. DPIS ~-1349 A&B WERE FOUND SET AT 33.3 AND 33.5 INCHES OF WATER. THE LIMIT IN *TABLE 3.2.1 IN 32 'INCHES OF WA.TER -

I

'"'.'*.;.-:~'?;.::£>'.*'.;;,;.;f::'swITCHES DPIS 3-1350 A'&B WERE 'RES°E'T TO. 416.5 AND 417.5 INCHES OF WATER. SWITCHES POIS 3-1349 A&B WERE RESET TO 2~.9

. AND 30.1 INCHES OF WATER-. PRESENT PLAN ARE TO CHANGE THE AS

  • LEFT SETTINGS ON THESE SWITCHES TO A LOWER.VALUE AT THE* NEXT CALIBRATION W P WORDEN SUPT DRESDEN 1 NUCLEAR POWER STAT ION 4XX 522PEDT USAEC HQS GTWN

/

- z 1972 SEP 25 PM 5 30 USAEC HQS GTWN I

WU WSH J..

TLXA226 C47>DEA064 KA248

. \\"'

K VEC134 P-DF TOVE MORRIS ILL 25 1035A COT

.EDWARD J BLOCH ACT:ING DIRECTOR, DIRECTORATE OF LICENSIN.G

,,::-~_...,._ --_-------

  • US ATOMIC ENERGY COMM WASHDC 20545

"., ~~ _,

SUBJECT DPR-25 DRESDEN NUCLEAR POWER STATION UNIT 3 THIS WILL

-~

CONFIRM THE CONVERSATION WITH MR H DANCE OF' YOUR OFFICE AT I. --

I

~-

0915 HOURS ~HIS DATE CONCERNING HIGH FLOW SWITCHES ON THE

l. **

ISOLATION CONDENSER B.EING OUT OF CALIBRATION. ON 9/22/72 A

(

~.

~OUTINE TH~EE_MONTH CALIB~ATION _WAS PERFORMED ON THE HIGH FLOW ISOL_ATION SWl'.fCHES* ALL FOUR SWITCHES SET POINDS WERE

,. ~ ~-- -* '~ ' *-*. ~

,..~

FO_t,JNP. GREATER THAN THE LJMI T IN TABLE 3.*2.* l __ OF THE TECHNICAL

~ ** !>,

~,

~

SPECIF'lCATl'ONS* THE HIGH STEAM FLOW.SW-1-TCHES. DPlS 3*1350

.. ~

A&B __ WERE-fO_UND SET'. AT 426. 5 AND 345* 5 INCHES OF WAT.ER*_ THE.,

./. -

L~M_IT IN _TABLE 3.2._1. _CORRES~9NQS TO. 4~5_ JNCHES OF WATER~ THE.

-*-**c4',

~.-.-~_..-,.._

.....,~1*......r"'--:*

o, I

I

. }i_~GH GONi;>ENSATE FL,OW SWI,i'CHES* DPI$ 3-1349 A&B WERE FOl)NO 'sET

+_.,.;..,

t.

AT_33~~ AND 33~5 INCHES OF WATER*

THE-LlMtT*I~ TABLE 3~2.t IN ~2 JNCHES OF WATER

,SWJTGHES QPIS 3:1350-A&~ WERE RESEr_:TO 416*5_AND 417.S

~NCHES OF_

WAT~.R~ SW!TCHES POIS ~:~~~9 A_&B WERE R_ESET_ TO ~9.9 ANp __ ~~~) ~-~CHES_ CW

~A!~R.,.. _P~~~~*~T PLAN ARE TO ~~~~G~ THE A-S LEf J' SET_TIN~S ON THES~ ~~I TC HES T.O A _LO~-~~ VALU_E ~T THE NEXT G.~-L.J B.RAJ l_()N

_i,J_

~ WORDEN_ SUPT DRESDEN Nl)CLEAR POWER STATlON 0

4XX __ 522PEOT U_SAEC H~S.GTWN

\\