Advises That 870901 Commitment Complete Const Activities by 1989 Refueling Outage,Per Deviation Noted in Insp Rept 50-244/87-11,delayed Until 891229.Deviation Covered Seismic Analysis & Supports for Standby Auxiliary Feedwater Sys
ML17251A553
Person / Time
Site: Ginna Constellation icon.png
Issue date: 06/19/1989
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To: Russell W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 8907050234
Download: ML17251A553 (10)


Text

'I ii g(gx,i4) ~~~el; ~sly/

ROCHESTER GAS AND ELECTRIC CORPORA77ON

~ 89 EAST AVENUE, ROCHESTER, N.Y.

i i

isis iisic 14649-0001 June 19, 1989

. c'+~o'ic sacs cooc.is 546-2700 Mr. William T. Russell Regional Administrator US Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406

Subject:

Inspection Report 50-244/87-11 O'E Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Russell:

The RGRE response to Inspection Report 50-244/87-11 was transmitted by RGRE letter dated September 1,

1987 from Roger W. Kober to William T.

Russell.

This response indicated, in part, that construction activities related to Inspection Report Deviation A (seismic analysis and supports for the Standby Auxiliary Feedwater System and portions of the Service Water System) were expected to be completed by the end of the 1989 Refueiing Outage.

RGGE has completed significant portions of the engineering and construction of this project, but is unable to complete activities by the projected date.

In addition to the work effort required to implement Bulletin 79-02, this work effort is also upgrading the affected piping and pipe supports to a more rigorous level, consistent with the remainder of the Seismic Upgrade Program.

This has presented several unanticipated analytical challenges.

These analysis complexities, together with higher than expected resource requirements, have resulted in a delay in the expected project completion date.

At present, nine of twelve analysis lines have engineering analysis of the piping and supports complete.

Six of these nine lines have been issued for construction and construction activities on these six lines are approximately 80% complete.

All work in containment was completed during the 1989 Refueling Outage.

The construction activities for all the remaining lines outside containment will be in progress during the post-

'89 outage period, and are expected to be completed by'December 29, 1989.

Very truly yours, Robert C. Mecredy General Manager Nuclear Production

(

2 GJWK046 xc:

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555 Allen R. Johnson (Mail Stop 14D1)

Project Directorate I-3 Washington, D.C.

20555 U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Ginna Senior Resident Inspector

ACCE

. S 8

05000244 NOTES:License Exp date -'in inaccordance with 10CFR2,2.109(9/19/72)'.

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

I CCESSION NBR: 8907050234 DOC. DATE: 89/06/19 'OTARIZED: NO DOCKET FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

05000244 AUTH.NAME.

AUTHOR AFFILIATION MECREDY,R.C.

'ochester Gas

& Electric Corp.

RECIP.NAME

'ECIPIENT AFFILIATION RUSSELL,W.T.

Region 1, Ofc "of the Director R

SUBJECT:

Advises that 870901 commitement to complete const activities

'I by 1989 refueling outage delayed until 891229.

DISTRIBUTION CODE: IEOID COPIES RECEIVED:LTR f ENCL g SIZE:

D TITLE: General (50 'Dkt)-Insp Rept/Notice of Violation Response RECIPIENT ID CODE/NAME PD1-3 PD INTERNAL: AEOD AEOD/TPAD NRR SHANKMAN,S NRR/DLPQ/PEB NRR/DREP/EPB 10, NRR/PMAS/ILRB12 RMAN,J G MLE 02 RGNl 01

'I TERNAL:.LPDR NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

.1 1

1.

1 RECIPIENT ID CODE/NAME JOHNSON,A

'EOD/DEIIB DEDRO NRR/DEST DIR NRR/DOEA DIR 11 NRR/DREP/RPB 10 NUDOCS-ABSTRACT OGC/HDS2 RES MORISSEAU,D NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 2

2 l.

1 1

1

~

1 1"

1

'h D

R NOZE 'IO ALL RIDS" RECCE'IE'RIS:

PEZASE HELP US 'IO REDUCE HASTE!

CXN33KT 'IHE DOCUMEÃZ CXNHK)L DESK, RXN Pl-37 (EXT. 20079)

TO ELXKBQXS~ MHB HKH DIBZRIBOTION LISTS PQR DCKXlHENTB VXJ DCÃsT NEED!

OTAL NUMBER OF COPIES REQUIRED:

LTTR 23 ENCL 23 D

D S

Ilp

'v@

ROCHESTER GAS AND ELECTRIC CORPORATION

~ 89 EAST AVENUE, ROCHESTER, N.Y. 14649.0001 NCw

$0tC

$1ATC June 19, 1989 TCL.KPwONC ARCA CODE 7ld 546 2700 Mr. William T. Russell Regional Administrator US Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406

Subject:

Inspection Report 50-244/87-11 R.E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Russell:

The RGGE response to Inspection Report 50-244/87-11 was transmitted by RGRE letter dated September 1,

1987 from Roger W. Kober to William T.

Russell.

This response indicated, in part, that construction activities related to Inspection Report Deviation A (seismic analysis and supports for the Standby Auxiliary Feedwater System and portions of the Service Water System) were expected to be completed by the end of the 1989 Refueling Outage.

RGGE has completed significant portions of the engineering and construction of this project-, but is unable to complete activities by the projected date.

In addition to the work effort required to implement Bulletin 79-02, this work effort is also upgrading the affected piping and pipe supports to a more rigorous level, co'nsistent with the remainder of the Seismic Upgrade Program.

This has presented several unanticipated analytical challenges.

These analysis complexities, together with higher than expected resource requirements, have resulted in a delay in the expected project completion date.

At present, nine of twelve analysis lines have engineering analysis of the piping and supports complete.

Six of these nine lines have been issued for construction and construction activities on these six lines are approximately 80% complete.

All work in containment was completed during the 1989 Refueling Outage.

The construction activities for all the remaining lines outside containment will be in progress during the post-

'89 outage period, and are expected to be completed by December 29, 1989.

Very truly yours, 8'M7050234 gei() g I P PDR AGQCK 05000244 9

PDC General Manager Nuclear Production

pl(

)$

GJWN046 zc:

UPS. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555 Allen R. Johnson (Mail Stop 14D1)

Project Directorate I-3 Washington, D.C.

20555 U.ST Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Ginna Senior Resident Inspector