ACCELERATED D1S1Fy3UT1 ON DE MON STRAgN SYSTEM 4

V REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8812190387 DOC.DATE: 88/11/30 NOTARIZED: NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

AUTH.NAME AUTHOR AFFILIATXON MCNAMARA,A.E.

Rochester Gas 6 Electric Corp,

- MECREDY,R.C.

Rochester Gas

& Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION DOCKET 05000244

'UBJECT:

Monthly operating rept for Nov '1988 for RE Ginna Nuclear Power Plant.W/881215 ltr.

DISTRIBUTION CODE:

IE24D COPIES RECEIVED:LTR ENCLi SXZE:

TITLE: Monthly Operating Report (per Tech Spec

)

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

S 05000244 RECIPIENT ID CODE/NAME PD1-3 LA STAHLE,C INTERNAL: AEOD/DOA ARM TECH ADV

'RR/DOEA/EAB11 NUDOCS-ABSTRACT RGN1 EXTERNAL: EGGG -SIMPSON, F LPDR NSIC COPIES LTTR ENCL 1

0 1

0 1

1 2

2 1

1 1

.1 1,

1 1

1 1

1 1

1 RECIPIENT XD CODE/NAME PD1-3 PD AEOD/DSP/TPAB NRR/DLPQ/PEB 11 N

EP/RPB 10 E~IL 01 EGGG WILLIAMS,S NRC PDR COPIES LTTR ENCL 5

5 1

1 1

1 1

1 1

1 1

1 1

1 R

I h

NOZE TO ALL "RIDS" RECIPIENIS'IZASE HELP US K) REDUCE WASTE!

CXNZACZ 'IHE DOCUMENI'GÃIK)LDESK, ROOM Pl-37 (EXT. 20079) K) ELOCUTE %SR NAME FKM DISTlGBUTIQN LISTS FOR DOCKlMENIS YOU DGNiT NEED(

TOTAL NUMBER OF COPIES REQUIRED:

LTTR.

22 ENCL 20

~ OPERATING STATUS OPERATING DATA REPORT DOCKET NO.

5 244 DATF cember 15, 1988 COMPLETED BY

.Oy1

~Andrew E. McN a

TFI.FPHONE 1(315)524-4446, Ext. 301

l. Unit Name:

R.E. 6IMNA hlUCI.EAR POWER PLANT 7

Reporting Period

November, 1988
3. Licensed Thermal Power (MWt):
4. Nameplate Rating (Gross MWe):
5. Design Electrical Rating (Net MWe):

470

6. Maximum Dependable Capacity (Gross MWe):

490

7. Maximum Dependable Capacity (Net MWe):

Notes No outages or major power reductions were experi-enced in the report period.

A minor reduction is detailed on Page 4.

8. IfChanges Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:
9. Power Level to Which Restricted, If Any (Net MWc)t
10. Reasons For Restrictions, If Any:

This Month Yr:to-Date Cumulative 166,680.00 130,953.61 1,687.55*

128,527.88 8.50*

180;866,359 9,938,626 59,424,345 56,387,607 77.11%

77.12%

73.39%

84.06%

73.39%

6.41%

11. Hours In Reporting Period 720.00
12. Number of Hours Reactor Was Critical 720.00 6,935.14
13. Reactor Reserve Shutdown Hours 0.00 0.00
14. Hours Generator On-Line 6,849.50
15. Unit Reserve Shutdown Hours 0.00
16. Gross Thermal Energy Generated (hlWH)
17. Gross Electrical Energy Gencratcd (MWH) 3,341,760
18. Net Flectrical Energy Gencratcd (MWH) 352,458 3,176,323
19. Unit Service Factor 100.00%

85.19%

20. Unit AvailabilityFactor 100.00%

85.19%

21. Unit Capacity Factor (Using hIDC Net) 104.15%
22. Unit Capacity Factor (Using,DER Nct) 104.15%

84.06%

23. Unit Forced Outage Rate 0.00%

'.70%

24. Shutdowns Scheduled Over Next 6 Months (Type, Date and Duration of Each):

Annual Refueling and Maintenance Shutdown - March 17, 1989 -- 49-55 da s I

25. If Shut Down At End Of Rcport.Period, Estimated Date of Startup:
26. Units In Test Status (Prior to Commercial Operation):

INITIALCRITICALITY INITIALELECTRICITY COMMERCIALOPERATION Forecast Achieved

  • Cumulative total cartnencing January 1,

1975.

881215'0387 881130 PDR ADOCK 05000244 R

PDC

l D

~

l, I

l 4

p II P,

2 AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-244 UNIT R.E.

Ginna Nuclear Power Plant DATE De ember 5

1988 COMPLETED BY Andrew E.

McNamara TELEPHONE 1

315 524-4446 Ext.

301 at Ginna MONTH November 1988 DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 489 17'89 2 ~

3 ~

4 ~

5.

6 ~

7 ~

8.

9.

10.

12.

13

'4

'5

'6.

489 489

'89 489 490 489 489 490 490 490 490 490 487 485 488 18.

19.

20.

21.

22

'3.

24.

25 ~

26.

27

'8

'9

'0.

31.

489 490 490 490 490 490 490 491 491 491 491 491 491 490 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

ft

NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.

50-244 UNIT R.E. Ginna Nuclear Power Plant DATE De e ber 15 1988 COMPLETED BY Andrew E.

McNamara TELEPHONE 1

315 524-4446 EXT. 301 at Ginna MONTH November 1988 The reactor power level was maintained at 1004 for the majority of the report period with no outages on major power reduction experienced.

The one minor exception was a power level reduction to 984 for a short period on November 15 to perform two periodic tests on the auxiliary feedwater system.

The reduction was of short duration and the reactor power level was restored to 1004 upon completion of the tests.

GINNA STATION MAINTENANCE REPORT

SUMMARY

OCTOBER, 1988 During the month of November, routine maintenance and inspections were completed.

Major safety related work included:

a 0 b.

c ~

d.

e.

g, Snubber inspection per M-40 Repaired broken pipe on R-21 P.I.

Remove blockage.in Boric Acid line Repaired tubing leak on Diesel Fire Pump Annual inspection on Tech.

Support Center Diesel Replace Radiation Vac.

Pump gR-10, 11, 12 Annual inspection Fire Diesel Engine and Pump Rebuild Toxic Monitor Pump 52 Annual minor inspection of "A" Service Water Pump Annual inspection of Security Diesel

Bil

'ESP I////

7/

////u7 gI { 0%IA1 NCV ROCHESTER GAS AND ELECTRIC CORPORATION o 89 EAST AVENUE, ROCHESTER, N.K 14649-0001 YELCPHONC ARE'A COOE 71 a 546.2700 GINNA STATION December 15, 1988 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Monthly Report for November, 1988 Operating Status; Information R.

E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Sir:

Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report for Ginna Station for the month of November, 1988..

Very truly yours, Robert C. Mecredy General Manager Nuclear Production RCM/eeh Attachments cc:

Mr. William T. Russell NRC (1)-

t'

~ ~

v 11