ROCHESTER GAS AND ELECTRIC CORPORA TIOk
~
S9 EAST AVENUE, ROCHESTER, H.Y. 14649 LEON D, WHITE, JR
~
VICE I'RESIDENT May 29, 1980 T EL i I'<0<C Aac* coot "lc 5<6'270O Mr. Boyce H. Grier, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406
Subject:
IE Bulletin No. 80-08 "Examination of Containment Liner Penetration Welds" R. E. Ginna Nuclear Power Plant, Unit Ql Docket No. 50-244
Dear Mr. Grier:
In reply to Inspection and Enforcement Bulletin 80-08, dated April 7, 1980, concerning containment penetration connections, a review of Ginna Station penetrations was performed.
It was determined that none of the containment penetrations at Ginna Station resemble the designs of concern in the subject bulletin.
Very truly yours,'.
D. Whit, Jr.
cc:
Director Division of Reactor Construction Inspection U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Washington, D. C.