Pr/I,ZiZilllgij',7/!Zi'Wi

//l/j 'tt',I/ k~'

'!glllizil,'Ifbi!/!I/i!i/i!llil ROCHESTER GAS AND ELECTRIC CORPORATION

~pic I"-~

III~

g ~

~ ysl e~

~

89 EAST AVENUE, ROCHESTER, N.Y. 14649 LEON D, WHITE. JR.

VICC PRKSIDENT TELCPHONC Aac~ cooc TiII 546.2700 March 21, 1980 Mr. Boyce H. Grier, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

IE Bulletin No. 80-03, Loss of Charcoal from Standard Type II, 2 Inch, Tray Adsorber Cells R. E. Ginna Nuclear Power Plant, Unit 41 Docket No. 50-244

Dear Mr. Grier:

In response to NRC IE Bulletin No. 80-03 an inspection of the charcoal filter cells has been completed at Ginna Station.

The inspection was conducted in accordance with a procedure which is consistent with the standard given in Section 5 of ANSI N510-1975.

The exception to this is the Spent Fuel Pool Charcoal Filter which was tested

.per section 12 of ANSI N510-1975.

This was because it was not feasible to visually inspect the cells in this unit.

A tabulation of the systems involved, cell manufacturer and type, and observed cell condition is provided in the attachment.

Very truly yours, L. D. White, Jr.

Att.

.xc: Director, Division of Fuel Facility and Materials Safety Inspection Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.

20555 8004 23000~

il

ch 21, 1980 Attachment IE Bulletin No. 80-03, Loss of Charcoal from Standard Type II, 2 Inch, Tray Adsorber Cells

~Setem "A" Containment Purge "B" Containment Purge Manufacturer and T e

Condition observed No deficiencies.

Noted evidence of corrosion on many screens.

Spacers loose in many filters.

No channeling or loss of charcoal has occurred.

Filters are being replaced although system is still operable.

"A" and "B" Auxiliary Building Charcoal Filter Filters generally in good physical condition.

One filter had slipped its spacers and was falling apart..

high D.P. had been previously noted and filters were due to be changed.

Controlled Access Filter Barnaby-Chancy FC Type SP 1521 No significant deficiencies.

Control Room Spent Fuel Pool Flanders Type II DT-10 No significant deficiencies.

Halide leak test performed.

99.41% leak efficiency.

"G" Air Handling Unit MSA Model ASK 1743-'692 No significant deficiencies.

"A" Kidney Filter Bank "B" Kidn'ey Filter Bank "A" Post Accident Filter MSA Model ASK Bank No significant deficiencies.

No significant deficiencies.

No significant deficiencies.

"B" Post Accident Filter MSA Model ASK

. Bank No significant deficiencies.

  • AAF filters are type with bolt and washer spacers.

p I