ML17249A286
| ML17249A286 | |
| Person / Time | |
|---|---|
| Site: | Ginna |
| Issue date: | 10/30/1979 |
| From: | White L ROCHESTER GAS & ELECTRIC CORP. |
| To: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| IEB-79-13, NUDOCS 7911230039 | |
| Download: ML17249A286 (2) | |
Text
il ROCHESTER GAS AND ELECTRIC CORPORATION sa
~ Owl 0
o 89 EAST AVENUE ROCHESTER N Y 14649 IIAII LEON O. WHITE. JR.
VICE PRESIDENT TELEPHONE ARCA CODE Tld 546-2700 October 30, 1979 Mr. Boyce H. Grier, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, PA 19496
Subject:
IE Bulletin No. 79-13 Westinghouse WCAP-9563 Metallurgical Analysis R.
E. Ginna Nuclear Power Plant Docket No. 50-244
Dear Mr. Grier:
In accordance with your request, we are submitting five (5) copies of the Westinghouse WCAP-9563 "Metallurgical Investi-gation of the Steam Generator Feedwater Piping Cracks at the Robert Emmett Ginna Nuclear Power Generating Station".
If you have any further questions, do not hesitate in con-tacting us.
Very truly yours, AEC:dma Enclosure xc:
U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Division of Reactor Operations Inspection Washington, DC 20555 Ten (10) Copies Dr. John Weeks Brookhaven National Laboratory
- Upton, NY 11973 Two (2) Copies
/