fjfQQ;[.,'EGULATORY XNFORMATXON DISTRIBUT SYSTEM DOCKET NBR:

50-244 RE GINNA.1 RECIPXENT:

ZIEMANN, D.L.

ORIGINATOR:

WHITE, L.D.

DOC DATE:

~

781120 ACCESSION NBR:

7811280216 COPIES RECEIVED:

COMPANY 'OCHESTER GAS 6 ELEC LTR 1

ENCL 0

SUBJECT:

Describes fuel inspec plans for 1979 shutdown.

SIZE:

2 At end of present Cycle 8

8 to 10 Exxon fuel assemblies will be inspec visually w/binoculars.

Shutdown 6 ins ec lanned for late Feb 6 early March, 1979.

DISTRIBUTION CODE e A001 DISTR)RUTIOt'ITLE3 OFNERAL DI8 TR IBUT ION FOR AFTER ISSUANCE OF OPF RAT I NQ LICENSE ~

NAttf BR CHIEF R

NRC PhR I

L E

GELD HANAUEP coRP aP'RFORHANcE RR AD FOR SYS 5

PR(iJ ENGINF.F RING Hft

'EACTnp SAFFTY HR PLANT SYSTE HS BR EER E'FFL'UF.NT TREAT SYS NC On<ttlH LPOR TERA NSIC ACRS ENCL?

w/7 ENCL W/ENCL w/ENCL W/P ENCL t TR nNLY w/ENCL w/ENCL W/ENCL

<</ENCL W/ENCL w/ENCL w/ENCL W/ENCL w/ENCL W/ENCL w/ENCL w/ENCL w/16 ENCL f

FOR ACTION

~

ORB82 BC TOTAL NUMBER OF

~ COPIES REQUIRED I LTR ENCL 40 3Q NOTES-

ROCHESTER GAS AHD ELECTRIC CORPORATION s*

~ 4 I ~

a So EAST AVENUE ROCHESTER N Y 14649 LEON D. WHITE, JR.

VICE IIRESIDENT T C I.C PH OR f AREA COOK TI6 546 2700 November 20, 1978 Director of Nuclear Reactor Regulations Attention:

Mr. D. K. Ziemann, Chief Operating Reactor Branch g2 U.S. Nuclear Regulatory Commission Washington, DC 20555 Re:

Rochester Gas and Electric Corporation R. E. Ginna Nuclear Power Station, Unit No.

1 Docket No. 50-244

Dear Mr. Ziemann:

The purpose of this letter is to address our fuel inspection plans for the 1979 shutdown.

The R. E. Ginna Nuclear Station is in its eighth fuel cycle.

Cycle 8 consists of 32 new Exxon Nuclear Co.

(ENC) fuel assemblies loaded at the core periphery and 89 exposed Westinghouse assemblies scattered loaded in the center of the core.

All assemblies are of similar design with the ENC assemblies designed to be compatible with the Westinghouse assemblies.

At the end of this cycle, 8 to 10 of the Exxon fuel assemblies will be visually inspected using binoculars.

This inspection plan is considered to be sufficient for the following reasons:

The primary coolant activity for this cycle has been extremely low.

The total activity is averaging around 8% of the Technical Specification limit.

This per-formance is as good as or better than our experience in previous cycles.

In addition, the all-rods-out hot-full-power boron concentration is within a few ppm of predictions and the difference between measured and predicted assembly powers is quite good with the average difference being only a few percent.

There-fore, Cycle 8 is performing as predicted with no indica-tion of any reactivity or cladding integrity problems.

During the summer of 1978 two Exxon fuel assemblies which had completed three cycles in the R.

E. Ginna core and accumulated a burnup of approximately 25,000 MWD/NTU each were examined.

The examination revealed the fuel assemblies to be in good condition with no abnormalities.

f~~-"<'J /i~>>>i ~neii~>>,

Oe v 8112804)Q 3 oOy

'0

I ROCHESTER GAS AND ELECTRIC CORP.

DATE November 20, 1978 To Mr. D. L. Ziemann, Chief SHEET NO.

Examinations by ENC of similar fuel at other facilities have not revealed any abnormalities.

Therefore, there is no reason to expect, any abnormalities in the R. E.

Ginna fuel.

The Cycle 8 shutdown is presently scheduled for February 1979 and the fuel inspection will be done in late February to early March, 1979.

Very truly yours, L. D. White, Jr.