From:
KRUEGER, Greg <gak@nei.org>
Sent:
Monday, August 07, 2017 4:39 PM To:
Lubinski, John
Subject:
[External_Sender] Anchor Darling Double Disc Gate Valve Industry Resolution Plan Update Attachments:
08-04-17_NRC_NEI Anchor Darling Valve Industry Resolution Plan Update August 4_Attachment.pdf; 08-04-17_NRC_NEI_Anchor Darling Double Disc Gate Valve Industry Resolution Plan Update Final.pdf August 4, 2017 Mr. John Lubinski Director, Division of Engineering Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Anchor Darling Double Disc Gate Valve Industry Resolution Plan Update Project Number: 689
References:
(1) Letter, G. Krueger (NEI) to J. Lubinski (NRC) Anchor Darling Double Disc Gate Valve Industry Resolution Plan, dated July 14, 2017 (2) Letter, B. Holian (NRC) to G. Krueger (NEI), Response from the Nuclear Regulatory Commission Regarding the Anchor Darling Double Disc Gate Valve Industry Resolution Plan, dated July 31, 2017
Dear Mr. Lubinski:
On behalf of the nuclear energy industry, the Nuclear Energy Institute (NEI) is pleased to provide, for your information, an update to the industrys near-term plan for addressing the Anchor Darling Double Disc Gate Valve (DDGV) issue. This plan update is intended to provide a status of the actions provided in our July 14, 2017 (Reference (1) above) and respond to the information requests listed in your July 31, 2017 letter (Reference (2) above).
The attached updated plan provides the industry actions to address recent Anchor Darling DDGV operational experience (OE), the revised Part 21, the development of additional technical guidance, and the industry strategy for utility action and response. The focus of this update is to provide the industry strategy (near and long term) for those sites with susceptible valves, with near term actions focused on those valves that are of high significance.
NEI continues to coordinate with industry organizations to assure effective communications and completion of recommended actions to remain aligned with the attached plan. We will also continue our interactions with the Staff to provide updates on the status of industry progress and address any
identified concerns or information needs. We consider this a living plan with future augmentation expected when necessary to reflect new information, updated issue resolution methods, and interaction results with the NRC.
If you have any questions or would like to discuss aspects of this industry plan, please do not hesitate to contact me.
Sincerely, Greg Krueger Senior Technical Advisor Nuclear Energy Institute 1201 F Street N.W., Suite 1100 Washington, DC 20004 www.nei.org P: 202.739.8099 E: gak@nei.org This electronic message transmission contains information from the Nuclear Energy Institute, Inc. The information is intended solely for the use of the addressee and its use by any other person is not authorized. If you are not the intended recipient, you have received this communication in error, and any review, use, disclosure, copying or distribution of the contents of this communication is strictly prohibited. If you have received this electronic transmission in error, please notify the sender immediately by telephone or by electronic mail and permanently delete the original message. IRS Circular 230 disclosure: To ensure compliance with requirements imposed by the IRS and other taxing authorities, we inform you that any tax advice contained in this communication (including any attachments) is not intended or written to be used, and cannot be used, for the purpose of (i) avoiding penalties that may be imposed on any taxpayer or (ii) promoting, marketing or recommending to another party any transaction or matter addressed herein.
Sent through www.intermedia.com