Notice of Violation from Insp on 960712.Violation Noted: Licensee Made Change to Facility Which Involved Unreviewed Safety Question Without Prior Commission Approval
ML17229A056
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 09/19/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML17229A055 List:
References
EA-96-236, EA-96-249, NUDOCS 9610030014
Download: ML17229A056 (7)


Text

NOTICE OF VIOLATION Florida Power and Light Company St. Lucie Nuclear Plant Docket Nos. 50-335.

50-389 License Nos.

DPR-67, NPF-16 EA 96-236 and 96-249 During an NRC inspection completed on July 12, 1996, violations of NRC requirements were identified.

In accordance with the "General Statement of Policy and Procedures for NRC Enforcement Actions," NUREG-1600. the violations are listed below:

10 CFR 50.59.

"Changes'ests and Experiments," provides, in part. that the licensee may make changes in the facility as described in the Safety Analysis Report (SAR) without prior Commission approval, unless the proposed change involves an unreviewed safety question.

A proposed change shall be deemed to involve an unreviewed safety question if the probability of occurrence of a malfunction of equipment important to safety previously evaluated in the SAR may be increased, if a possibi)ity for an accident or malfunction of a different type than any evaluated previously in the SAR may be created, or if the margin of safety as defined in the basis for any technical specitication is reduced.

Contrary to the above, in July 1995. the licensee made a change to the facility which involved an unreviewed safety question without prior Commission approval.

Specifically. the 28 Emergency Diesel Generator (EDG) fuel oH line was manually isolated to secure a through-wall fuel oil leak.

In taking this actions the licensee introduced two new fai lure modes for the 28 EDG, which both increased the probability of occurrence of a malfunction of the EDG above that previously evaluated in the SAR and the possibility for malfunction of a different type than any evaluated previously in the SAR

~ resulting in an unreviewed safety question.

(01013)

This is a Severity Level III violation (Supplement I)

II.

10 CFR 50, Appendix 8, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants." Criterion III requires, in part.

that measures be established to assure that applicable regulatory requirements and the design basis for safety-related structures,

systems, and components are correctly translated into specifications,
drawings, procedures, and instructions.

Florida Power and Light Company Topical Quality Assur ance Report.

TQR 3.0

~ Revision 11 implements these requirements.

Section 3.2, "Design Change Control." provides, in part. that design changes shall be reviewed to ensure their implementation is in each case, coordinated with any necessary changes to operating procedures.

In addition, Section 3.2.4

~ "Design Verification," provides.

in part

~ that design control measures shall be established to verify the design inputs'esign

process, and that the design inputs are correctly incorporated into the design output.

9hi00300i4 9609i9 PDR ADOCK 05000335 8

PDR

Notice of Violation A.

Contrary to the above, the licensee failed to coordinate design changes with the necessary changes to operating procedures as evidenced by the following examples:

Plant Change/Modification (PC/M) 109-294, "Setpoint Change to the Hydrazine Low Level Alarm (LIS-07-9)," was completed on January 6,

1995, without ensuring that affected Procedure ONOP 2-0030121.

"Plant Annunciator Summary,"

was revised.

This resulted in Annunciator S-10, "HYDRAZINE TK LEVEL LO,"

showing an incorrect setpoint of 35.5 inches in the procedure.

2.

PC/H 268-292 'Intake Cooling Water Lube Water Piping Removal and Circulatory Water Lube Water Piping Renovation,"

was completed on February 14, 1994, without ensuring that affected Procedure ONOP 2-0020131, "Plant Annunciator Summary,"

was revised.

This resulted in the instructions for Annunciator E-16, "CIRC WTR PP LUBE SPLY BACKUP IN SERVICE." incorrectly requiring operators to verify the position of valves HV 21-4A and 4B following a safety injection actuation system signal to ensure they were de-energized and had no control room position indication.

PC/H 275-290.

"Flow Indicator/Switch Low Flow Alarm and Manual Annunciator Deletions ~

" was completed on October 28, 1992. without ensuring that affected Procedure ONOP 2-0030131.

"Plant Annunciator Summary,"

was revised.

This resulted in the instructions for safety-related Annunciators LA-12.

"ATH STH DUMP HV-08-18A/18B OVERLOAD/SS ISOL," and LB-12, "ATH STH DMP MV-08-19A/19B OVERLOAD/SS ISOL," incorrectly requiring operators to check Auto/Manual switch or switches for the manual position.

(02014)

This is a Severity Level IV violation (Supplement I).

Contrary to the above.

the licensee failed to assure that the design of the Circulating and Intake Cooling Water System was correctly translated into plant drawings.

Specifically, during implementation of PC/M 341-192.

"Intake Cooling Water Lube Water Piping Removal and Circulatory Water Lube Water Piping Renovation," the as-built Drawing No. JPN-241-192-008 was not incorporated into Drawing No. 8770-G-082, "Flow Diagram Circulating and Intake Cooling Water System."

Revision

11. Sheet 2, issued Hay 9, 1995, for PC/H 341-192.

This resulted in Drawing No. 8770-G-082 erroneously showing valves 1-FCV-21-3A and 3B and associated piping as still installed.

(03014)

This is a Severity Level IV violation (Supplement I).

Pursuant to the provisions of 10 CFR 2.201. Florida Power 8 Light Company is hereby requi red to submit a written statement or explanation to the

Notice of Violation U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, D.C. 20555 with a copy to the Regional Administrator, Region II, and a copy to the NRC Resident Inspector at the facility that is the subject of this Notice.

within 30 days of the date of the letter transmitting this Notice of Violation (Notice).

This reply should be clearly marked as a "Reply to a Notice of Violation" and should include for each violation:

(1) the reason for the violation, or, if contested.

the basis for disputing the violation, (2) the corrective steps that have been taken and the results

achieved, (3) the corrective steps that will be taken to avoid further violations, and (4) the date when full compliance wi 11 be achieved.

Your response may reference or include previous docketed correspondence. if the correspondence adequately addresses the required response.

If an adequate reply is not received within the time specified in this Notice.

an order or a

Demand for Information may be issued as to why the license should not be modified, suspended, or revoked.

or why such other action as may be proper should not be taken.

Where good cause is shown. consideration will be given to extending the response time.

Under the authority of Section 182 of the Act, 42 U.S.C.

2232, this response shall be submitted under oath or affirmation.

Because your response will be placed in the NRC Public Document Room (PDR), to the extent possible, it should not include any personal privacy, proprietary.

or safeguards information so that it can be placed in the PDR without redaction.

If personal privacy or proprietary information is necessary to provide an acceptable

response, then please provide a bracketed copy of your response that identifies the information that should be protected and a

redacted copy of your response that deletes such information.

If you request withholding of such material, you must specifically identify the portions of your response that you seek to have withheld and provide in detai 1 the bases for your claim of withholding (e.g., explain why the disclosure of information will create an unwarranted invasion of personal privacy or provide the information required by 10 CFR 2.790(b) to support a request for withholding confidential commercial or financial information). If safeguards information is necessary to provide an acceptable response.

please provide the level of protection described in 10 CFR 73.21.

Dated at Atlanta. Georgia this 19th day of September 1996

Florida Power 8 Light Company Distribution w/encl:

PUBLIC

EJulian, SECY
BKeeling, CA
JTaylor, EDO JHi lhoan, DEDR RZimmerman, NRR
SEbneter, RII LChandler, OGC JGoldberg, OGC JLieberman, OE Enforcement Coordinators RI, RIII, RIV
EHayden, OPA
EJordan, AEOD PRabideau.

OC

DDandois, OC
GCaputo, OI HBell, OIG OE:EA File (B. Summers, OE)

HSatorius, OE AGibson, RII

JJohnson, RII CEvans.

RII BUryc, RII KClark, RII RTrojanowski, RII

CCasto, RII KLandis. RII
JNorris, NRR ABoland, RII (2 letterhead)

NRC Resident Inspector U.S. Nuclear Regulatory Comm.

7585 South Highway A1A Jensen

Beach, FL 34957-2010

florfda Power 4 Lfght Company P

L C EJul)an, SECY BKee'tfno, CA JTa 'lor EGO NRC Restdent Inspector U.S. Nuclear Regulatory Comm.

15SS South Hfghway AIA densen

Beach, FL 34961-2010 JIIffhoah, DEOR Rlf
eagan, NRR'Eb
eter, RII LCh ndler, OGC JGo dbcirg, OGC JLf berman, OE Enf rclment Coordfnators R, RIII, RIV EH dens OPA.

EJo. day, AEOO PR 'bfdoau, OC OD ndofs, OC GC (uIo( Ol OE)EA,Ffle (8.

Summers, OE) {2 letterhead)

HSgtorfus, OE AG)bson, RII

JJohnson, RII
CEvans, RII BUrgc RII K Iaok, RII R rolanowakI, Rll C asto, RII K andfs, RII J orrfs, NRR A oland, RII PANIC P('hm.

I I

I OE NRR RII HSatorfus R2<mmerman SFbneter 09 ~

96 09 96 09 tO 96 Doc:

Name:

6:~OECASES)06236REV.NS lf erman JHflhoan 09

+

96 09 96

1

~