ML17229A024
| ML17229A024 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 08/29/1996 |
| From: | Verrelli D NRC Office of Inspection & Enforcement (IE Region II) |
| To: | Plunkett T Florida Power & Light Co |
| References | |
| NUDOCS 9609090391 | |
| Download: ML17229A024 (7) | |
Text
August 29, 1996 Florida Power and Light Company ATTN:
Mr. T.
F. Plunkett President
- Nuclear Division P. 0.
Box 14000 Juno
- Beach, FL 33408-0420
SUBJECT:
MAINTENANCE RULE BASELINE TEAM INSPECTION (NRC INSPECTION REPORT NOS. 50-335/96-13 AND 50-389/96-13)
This letter confirms a telephone call between Mr.
W. Holland of my staff and T. guillan of Florida Power and Light Company on August 28,
- 1996, in which we requested additional material in preparation for the Maintenance Rule Baseline team Inspection at St. Lucie.
A description of the material requested is outlined in the enclosure.
We appreciate your cooperation on this matter.
Sincerely, ORIGINAL SIGNED BY:
MVIDM. %RREILX Docket Nos.:
50-335 and 50-389 License Nos.:
Enclosure:
As Stated cc w/encl:
J.
A. Stall Site Vice President St.
Lucie Nuclear Plant P. 0.
Box 128 Ft. Pierce, FL 34954-0128 H.
N. Paduano, Manager Licensing and Special Programs Florida Power and Light Company P. 0.
Box 14000 Juno
- Beach, FL 33408-0420 (cc w/encl cont'd
- See Page 2)
David M. Verrelli, Acting Chief Maintenance Branch Division of Reactor Safety 960909039i 960829 PDR ADQCK 05000335 8
FP&L (cc w/encl cont'd)
J. Scarola Plant General Manager St. Lucie Nuclear Plant P. 0.
Box 128 Ft. Pierce, FL 34954-0128 E. J.
Weinkam Plant Licensing Manager St. Lucie Nuclear Plant P. 0.
Box 128 Ft. Pierce, FL 34954-0218 J.
R.
- Newman, Esq.
- Morgan, Lewis L Bockius 1800 M Street, NW Washington, D. C.
20036 John T. Butler, Esq.
- Steel, Hector and Davis 4000 Southeast Financial Center
- Miami, FL 33131-2398 Bill Passetti Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Boulevard Tallahassee, FL 32399-0700 Jack Shreve, Public Counsel Office of the Public Counsel c/o The Florida Legislature 111 West Madison Avenue, Room 812 Tallahassee, FL 32399-1400 Joe Myers, Director-Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee',
FL 32399-2100 Thomas R.
L. Kindred County Administrator St. Lucie County 2300 Virginia Avenu~.
Ft. Pierce, FL 34982 Charles B. Brinkman Washington Nuclear Operations ABB Combustion Engineering, Inc.
12300 Twinbrook Parkway, Suite 3300 Rockville, MD 20852 Distribution w/encl:
(See page 3)
4 FP&L K. Landis, RII J. Norris, NRR B.
R. Crowley, RII G. A. Hallstrom, RII PUBLIC NRC Resident Inspector U.S. Nuclear Regulatory Comm.
7585 South Highway AlA Jensen
- Beach, FL 34957-2010 OFFICE SIGNATURE NAME DATE 08
/98 08/
/98 08/
/96 08/
/96 08/
/96 08/
/96 COPY)
YE NO YES NO YES NO OFFICIAL RECO 8 COPY OOCUHEHT HARE:
P: iIIAIHT.RUL YES NO YES NO YES NO
INFORMATION REQUESTED FOR MAINTENANCE RULE BASELINE TEAM INSPECTION 1.
Updated risk ranking of structures,
- systems, and components (SSCs) and the importance measure(s) utilized to establish the risk significance of these SSCs for the Maintenance Rule 2.
Any updated material to the initial IPE submittal 3.
Minutes of expert panel meetings Listing of top 20 non-risk significant SSCs which missed the criteria for being risk significant 5.
List of SSCs classified as "inherently reliable" 6.
SSCs classified for "run to failure" 7.
Copies of LCO log(s) and equipment tagging log(s) since July 10, 1996 8.
Listing of SSCs downgraded/changed to non-risk significant by the expert panel and the rational for the change Copies of SRO and RO logs since July 10, 1996 10.
Definition of "availability" at site 11.
Copies of condition adverse to quality reports (including corrective actions or proposed corrective actions) associated with identification of problems during implementation of the Maintenance Rule, including PRA aspects