PR.IC3R.I EY' ACCELERATED RIDS PROCESSING)

REGULATORY XNFORMATION DISTRXBUTION SYSTEM (RIDS)

ACCESSION NBR:9502150075 DOC.DATE: 95/02/08 NOTARIZED: NO FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power

& Light Co.

AUTH.NAME AUTHOR AFFILXATION SAGER,D.A.

Florida Power 6 Light Co.

RECIP.NAME RECIPIENT 'AFFILIATION Document Control Branch (Document Control Desk)

DOCKET N

05000335

SUBJECT:

Forwards "Second 10-Yr ISI Interval IST Program for Pumps 6

Valves St Lucie Nuclear Power Plant Unit 1," rev 5.

DISTRIBUTION CODE:

A047D COPIES RECEIVED:LTR

! ENCL Q SIZE: P.f l5 TITLE: OR Submittal: Inservice/Testing/Relief from ASME Code GL-89-04 NOTES:

RECIPIENT ID CODE/NAME PD2-2 LA NORRIS,J INTERNAL: ACRS CEN NRR/DE/EMEB OGC/HDS3 EXTERNAL: LITCO BROWN, B NOAC COPIES LTTR ENCL 1

1 1

1 6

6 1

1 1

1 1

0 1

1 1

1 RECIPIENT ID CODE/NAME PD2-2 PD AEOD/SPD/RAB NRR/DE/EMCB NUDOCS-ABSTRACT RES/DSIR/EIB LITCO RANSOME,C NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVASTE!CONTACTTIIE DOCU;"v!ENTCONTROL DESK, ROOM Pl-37 (EXT. 504-2083 ) TO ELIS!!NATE YOUR VAMLPROiI DISTRIBUTIONLISTS I'OR DOCL'MEN'I'S YOU DON"I'L'ED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 20 ENCL 19

>5

'I i

Florida Power fk Light Company, P.O. Box 128, Fort Pierce, FL 34954-0128 February 8,

1995 L-95-48 10 CFR 50.4 U.

S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.

C.

20555 RE:

St. Lucie Unit 1 Docket No. 50-335 Second Ten Year In Service Inspection Interval In Service Test Pro ram Revision 5

Enclosed for your Year In Service Revision

5. This Safety Evaluation information is the St. Lucie Unit 1, Second Ten Inspection
Interval, In Service Test
Program, revision incorporates changes based on the NRC dated September 27, 1994.

Attachment 1 is a

summary of the changes incorporated into this revision.

Please contact us if there are any questions about this submittal.

Very truly yours, D. A.

ger Vice sident St.

L c e Plant DAS/GRM cc:

Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant

~ pr~oAQ 9502150075 950208 PDR ADGCK 05000335 P

PDR an FPL Group company

C,4H~

4 ~

l LI

'i I

St. Lucie Unit 1 Docket No. 50-335 Second Ten Year In Service Inspection Interval In Service Test Pro ram Revision 5

Summary of Changes for St. Lucie Unit 1 In Service Testing Program Revision 5

The introduction has been revised to reference the NRC approval to the use of ASME/ANSI OM-1987, Part 1 requirements as an alternative to ASME Section XI, 1983 Edition, Subsection IWV-3510 requirements for testing of safety and relief valves.

The approval is included in the NRC Safety Evaluation of St.

Lucie Unit 1 In Service Testing Program Relief Requests dated September 27, 1994.

Revised relief request PR-12, which was approved by NRC Safety Evaluation dated August 5,

1994 has been incorporated into this revision.

The approval sections of relief requests PR-5, VR-29, VR-30, VR-39, VR-40, and VR-41, have been revised to incorporate approval of these relief requests which was documented in NRC Safety Evaluation dated September 27, 1994.

Relief requests VR-12 and VR-13 have been revised to denote that full stroke verification of the check valves be performed utilizing non-intrusive test methods in accordance with Generic Letter 89-04.

0

- ~ ~

e A

h

" >i>4"pig, T