ML17219A368

From kanterella
Jump to navigation Jump to search
Amend 67 to License DPR-77,lowering Max Allowable Power Level for Linear Heat Rate Monitoring Using Excore Detector Sys from 88% to 85% When Peripheral Axial Shape Index Between 0.02 & 0.08
ML17219A368
Person / Time
Site: Saint Lucie 
Issue date: 02/19/1987
From: Thadani A
Office of Nuclear Reactor Regulation
To:
Florida Power & Light Co
Shared Package
ML17219A369 List:
References
DPR-67-A-077 NUDOCS 8702270436
Download: ML17219A368 (6)


Text

~y,S Rfgy C~

O UNITEDSTATES NUCLEAR REGULATORYCOMMISSION WASHINGTON, D. C. 20555 FLORIDA POWER 8

LIGHT COMPANY DOCKET NO. 50-335 ST.

LUCIE PLANT UNIT NO.

1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.

77 License No.

DPR-67 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Florida Power 8 Light Company, (the licensee) dated December 18, 1986 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

870pp70496 gy02g9 P

PDR

0 N

h'

2.

Accordingly, Facility Operating License No.

DPR-67 is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and by amending paragraph 2.C.(2) to read as follows:

(2)

Technical S ecifications The Technical Specifications contained in Appendices A

and B, as revised through Amendment No.

77

, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

Attachment:

Changes to the Technical Specifications As k C. Thadani, Director PW Project Directorate 08 Division of PWR Licensing-8 Date of Issuance:

February 19, 1987

ATTACHMENT TO LICENSE AMENDMENT NO.

77 TO FACILITY OPERATING LICENSE NO.

DPR-67 DOCKET NO. 50-335 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page.

The revised page is identified by amendment number and contains vertical lines indicating the area of change.

The corresponding overleaf page is also provided to maintain document com-pleteness.

Remove Pa e

3/4 2-4 Insert Pa e

3/4 2-4

UNACCEPTABLE OPERATION 15 (0.6, 15.0)

(0.81, 14.0)

IX zH O

10 OZ ACCEPTABLE OPERATION (1.0, 10,81 0

,0. 0 0.5 1.0 FRACTION OF CORE HEIGHT FIGURE 3.2-1 ALLOWABLE PEAK LINEAR HEAT RATE VERSUS FRACTION OF CORE HEIGHT ST.

LUCIE - UNIT 1

3/4 2-3 Amendment No. g7,gg,gg,70, 74

1.2 1.0 REGION OF UNACCEPTABLE OP ERAT ION 0.9 0.8 0.7 o

0.6 0.5

(-0.3,0.48)

(0.02,0.85)

(0.08,0.85).

REGION OF ACCEPTABLE OPERATION REGION OF UNACCEPTABLE OPERATION (0.3,0.67) 0.4

-0.6

-0.4

-0.2 0.0 0.2 0.4 '.6 PERIPHERAL AXIAL SHAPE INDEX FIGURE 3.2-2 AXIAL SHAPE INDEX VS-MAXIMUMALLOWABLE POWER LEVEL PER SPECIFICATION 4.2.1.3 ST.

LUCIE - UNIT 1

3/4 2-4 Amendment:

No. g7,gg,fg,7g,7/4