gal 4EOy g4

~

+

0 n

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 FLORIDA POWER

& LIGHT COMPANY DOCKET NO. 50-335 ST.

LUCIE PLANT UNIT NO.

1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 64 License No.

DPR-67 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Florida Power 8 Light Company, (the licensee) dated September 16, 1983 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of'he Commission's regulations and all applicable requirements have been satisfied.

, 84040

" "050ooss5 g 840~<4

'gR ADOCK PDR P

0 (V

I

2.

Accordingly, Facility Operating License No.

DPR-67 is amended by changes to the Technical Specifications as indicated in the attach-ment to this license amendment, and by amending paragraph 2.C.(2) to read as follows:

(2)

Technical S ecifications The Technical Specifications contained in Appendices A

and 8, as revised through Amendment No. 64

, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifica-tions.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

Attachment:

Changes to the Technical Specifications Date of Issuance:

March I4, Ig84 James R. Miller, Chief Operating Reactors Branch P3 Divis ion of Licensing

ATTACHMENT TO LICENSE AMENDMENT NO.

TO FACILITY OPERATING LICENSE NO.

DPR-67 DOCKET NO. 50-335 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

The corresponding overleaf pages are also provided to maintain document com-pleteness.

~Pa es 3/4 6-5 3/4 6-9

~

CA

~e J

Penetration c

7 10 ll 14 23 24 25 26 O

28

'e System Makeup Water Station Air Instrument Pir Containment Purge Containment Purge Haste Management Component Cooling Component Cooling Fuel Transfer Tube CVCS Sattjpling Gate (I-MV-15-1)

Check (I-V-15-1347}

Gl obe (I-V-18-947}

Gl obe (I-Y-18-947.}

Gate (IWV-18-1.)

Check (I-V-18-957}

Butterfly (I-FCY-25-4)

Butterfly (I-FCV-25-5)

Butterfly (I-FCY-25-3)

Butterfly (I-FCY-25-2}

Globe (V-6741}

Check (V-6779)

Butter.fly (I-HCV-14-7)

Butterfly (I-HCV-14-1 }

Butterfly (I-HCV-14-6)

Butterfly (I-HCV-14-2),

Double Gasket Flange Outside Inside Outside Outside Outside Inside Inside Outsi,de Inside Outside Outside Outside Outside Outside Outside Outside Inside Globe (V-2515)

Globe (Y-2516)

G1obe (V-5200)

Globe (Y-5203)

Gl obe.(I-FCY 1 E Globe (I-FCV-03-1F Inside Inside Outside Outside Outside Outside TABLE 3.6-1 CONTAINMENT LEAKAGE PATHS Location Valve Ta Number to Containment Service Test T~e*

Containment Purge Exhaust Containment Purge Supply Nitrogen supply to SI Tanks RC Pump CW supply RC Pump CW Return Fuel Transfer Letdown Line Reactor Coolant Sample SI Tank Sample SI Tank Sample Type C

Type C

Bypass Bypass.

Bypass Bypass Bypass Bypass Bypass Primary Makeup Water Bypass Station Air Supply Bypass Instrument Air Supply Bypass

TABLE 3.6-1 Continued Penetration

~S stem Valve Ta Number Location to Containment Ser vice Test

~Te*

29 29 31 Sampling Sampling Waste Management Globe (V-5202)

Globe (V-5205)

Globe (V-5201)

Globe V-5204)

Gate (V-6554)

Gate V-6555 Outside Outside Outside Outside Outside Outside Pressurizer Steam Space Sample Pressurizer Surge Line Sample Containment Vent Header Bypass Bypass Bypass 41 Safety Injection Gate (V-3463)

Tank Test Lines Gate (I-V-03-1307)

Outside Outside Safety Injection Tank Bypass Fill and Sampling 42 43 44 46 47 48 Waste Management Waste Management CVCS Fuel Pool Cleanup Fuel Pool Cleanup Sampling Gate (I-LCV-07-11A)

Gate (I-LCV-07-11B)

Gate (V-6301)

Gate.(V-6302)

Gate.(V-2505)

Gate (I-SE-01-1)

Gate (I-V-07-206)

Gate (I-V-07-189 Gate (I-V-07-170)

~

Gate (I-V-07-388)

Globe

( I-FSE-27-01,02, 03,04)

Globe (I-FSE-27-08)

Outside Outside Outside Outside Outside Inside Outside Inside Outside Inside Inside Outside Reactor Cavity Sump Pump Discharge Reactor Drain Tank Pump Suction RC Pump Controlled Bleedoff Refueling Cavity Purification Flow Inlet Refueling Cavity Purification Flow Outlet H2 Sampling Bypass Bypass Bypass Bypass Bypass Type C

TABLE 3.6-1 Continued h

Penetration

~S stem Feedwater Steel Containment Nozzles Valve Ta Number Tap 1

Tap 2

Location to Containment Outside Outside Service Expansion Bellows Test e*

Type B

25 Fuel Tube Steel Containment Nozzles Tap 1

Inside Expansion Bellows Type B

  • Type C and bypass tests are conducted in the same manner, the only difference is in the acceptance criteria that is applicable.
    • In accordance with Specification 4.6.1.3.b.

4 ss I

l I

)

'IX a

,e CL CD 1

~ Q

A CONTAINMENT'SYSTEMS CONTAINMENT AIR LOCKS LIMITING CONDITION FOR OPERATION 3.6.1.3 Each containment air lock shall be OPERABLE with:

a.

b.

Both doors closed except when the air lock is being used for normal transit entry and exit through the containment, then at least one air lock door shall be closed, and An overall air lock leakage rate of < 0.05 La at Pa, (39.6 psig).

APPLICABILITY:

MODES 1, 2, 3 and 4.

ACTION:

a

~

With an air lock inoperable, except as a result of an inoperable door gasket, restore the air lock to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

b.

With an air lock inoperable due to an inoperable door gasket:

1.

Maintain the remaining door of the affected air lock closed and sealed, and 2.

Restore the air lock to OPERABLE status within 7 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.1.3 Each containment air lock shall be demonstrated OPERABLE:

a

~

After each opening by verifying the seal leakage is

< 0.01 L

as determined by precision flow measurement when measured for at least 30 seconds with:

1

~

The volume between the personnel air lock seals at a

constant pressure of 39.6 psig, and 2.

The volume between the emergency air lock seals at a

constant pr essure of 10 psig.

ST.

LUCIE - UNIT 1

3/4 6-10