REGULATORY l RMATION DISTRIBUTION SYST (RIDS)

ACCESSION NBR;8403190227 DOC ~ DATE: 84/03/13 NOTARIZED:

YES DOCKET FACILt50"389 St Lucie Planti Unit 2~ Florida Power 8 Light -Co.

05000389

'UTH, NAME AUTHOR AFFILIATION WILLIAMS'>N~

Flor ida Power 8 Light Co.

PECIP ~ NAME RECIPIENT AFfILIATION EISENNUT,D,G, Division of Licensing

SUBJECT:

APplication,to amend License Npp-la,changing Tech Specs to permit reracking of spent fuel pool to ensure.sufflojeggy jj slorage capacity ApproVal requested by 04090lo Oy)

DISTRIBUTION CODE:

A001S

'COPIES RECEIVED:I.TR ~

~

SIZE:

T?TLE:

OR Submittal:

General Distribution NOTESs RECIPIENT Ib CODE/NAME NRR ORB3 BC 01 INTERNAL: ELD/HDS2 NRR/DL DIR NRR METB COPIES LTTR ENCL 7

7 0

1 1

1 1

1 RECIPIENT ID CODE/NAME NRR/DE/MTEB NRR/DL/ORAB NRR/DSI/RAB RGN2 COPIES LTTR ENCL 1

1 0

1 1

1 EXTERNAL: ACRS NRC PDR NTIS 09 02 6

6 1

1 LPDR NSIC 03 1

05,1 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 25 ENCL 23

P'jr) pl l

I(5;$lj$

I filfL1'414 l( )pl 4)>>

'(,I I(" <<)

( ) f Q%

((.I( (&gal((g

$ f f fggc

()gg)l((1I 1 gpss f( I l

1 Agl() j iI<4 l<<h

- ~

(4(thwv',i@~~

I" j i' j(rl i I('

jl 1

f)P f 'f ~

3 f 1 ') ('4 f " <

0 JT

)(1 i I

l (l y I

)$ 4 IIj JINX(lrl j $

.Jl f (4(~

j

?l

\\

P, "JX 14000, JUNO BEACH, FL 33408

+llbg FLORIDAPOWER & LIGHTCOMPANY March 13, I 984 L-84-47 Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut, Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Eisenhut:

Re:

St. Lucie Unit No. 2 Docket No. 50-389 Proposed License Amendment S ent Fuel Pool Rerack In accordance with IO CFR 50.90, Florida Power & Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating License NPF-I 6.

This amendment is requested to permit reracking the spent fuel pool to ensure that sufficient capacity continues to exist for storage of spent fuel at St. Lucie Unit 2.

The proposed Technical Specification amendment is described below and shown on the accompanying Technical Specification page 5-4.

Specification 5.6.la.

is changed to indicate the total uncertainty value applied to the value of Keff for the new storage

racks, and to delete the FSAR reference.

The FSAR section will be updated as required per IO CFR 50.7 I (eX3XI).

2.

Specification 5.6.lb.

is changed to show the nominal center-to-center distance for the new storage racks.

3.

Specification 5.6.lc.

is added to specify the required boron concentration for the spent fuel pool.

~ "'

4.

5.

Specification 5.6.I 'is change'd to delete the statement regarding dr'y storage

'of new fuel for the first core.

This statement is no longer applicable.

Specification 5.6. I is changed to add a

sta tement defining the enrichment/burnup requirements for storage of fuel in each region of the fuel pool.

6.

Specification 5.6.3 is changed to show the capacity of the new storage racks.

g403190227 840313

' 'I IP

~o>>

PEOPLE... SERVING PEOPLE

V f

'J

Page 2 Office of Nuclear Reactor Regulation Mr. Darrell G. Eisenhut, Director Division of Licensing U. S. Nucleai Regulatory Commission The safety analysis justifying the Spent Fuel Pool Rerack and the proposed Technical Speci fications is attached.

In accordance with IO CFR 50.9I(aXI), it has been determined that the proposed amendment does not involve any significant hazards considerations pursuant to IO CFR 50.92.

The No Significant Hazards Considerations determination is attached.

In accordance with IO CFR 50.9I(bXI) a copy of the proposed amendment is being forwarded to the State Designee for the State of Florida.

The proposed amendment has been reviewed by the St. Lucie Facility Review Group and the Florida Power Bc Light Company Nuclear Review Board.

The proposed amendment has been determined to be a Class III amendment, and in accordance with 10 CFR I 70.22, a check for $4,000.00 is attached.

It is requested that NRC approve the rerack and proposed Technical Specifications no later than September I, l984.

This request is made in the interest of ALARA and safety considerations.

That is, there is currently no spent fuel in the St. Lucie Unit 2 spent fuel pool.

The pool is clean and dry and installation of the new racks can be performed without undue exposure to radiation or the possiblity of a construction accident with respect to nuclear criticality.or radioactive release.

For these reasons Florida Power Bc Light Company believes that NRC's efforts to meet the September I,

I 984 schedule are justified.

Very truly yours, ku J. W. Williams, Jr.

Vice President Nuclear Energy JWW/RJS/cab Attachments cc:

J. P. O'Reilly Regiona I Administrator, Region II U. S. Nuclear Regulatory Commission IOI Marietta Street, N.W., Suite 2900 Atlanta, GA 30303 Ulray Clark, Administrator Radiological Health Services Department of Health and Rehabilitative Services I 323 Winewood Boulevard Tallahassee, Florida 3230 I

A,

STATE OF FLORIDA

)

)

ss.

COUNTY OF DADE

)

J. W. Williams Jr., being first duly sworn, deposes and says:

That he is a Vice President of Florida Power 8

Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said Licensee.

J. W. Williams, Jr.

I Subscribed and sworn to before me this

/~day of

, 19+

I

',.>-NO AAY PUBL C, in and for the County of Dade, State of Florida.

My commission expires:

o ARY PlSLlC STATE pp rLpIIIDA'AT LA/~

V CPMMISSION EXpIRE5 pEC q I984, T""" <<NEPAL I>S. WDEIIgPI TERS

/

P

~ h p

E'p f ~

V t'~