MAPPING DISCUSSION:
ILLUSTRATING HOW DRAFT NEI 96-07 APP D CAN UTILIZE INFO FROM DRAFT NEI 16-16 David Ramendick NEI 96-07 Appendix D Team Nuclear Energy Institute August 1, 2017
- Identify the Appendix D terminology that can be mapped to NEI 16-16.
- Describe the difference between Appendix D terminology and NEI 16-16 terminology.
- For the Appendix D terminology that can be mapped to NEI 16-16, illustrate how Appendix D utilizes the technical information from NEI 16-16 to respond to Evaluation Questions 1, 2, 5 and 6.
- Discuss Beyond Design Basis Terminology PURPOSE
TYPICAL DESIGN CHANGE PROCESS Perform Technical Evaluations Perform Licensing Review (i.e., apply 10 CFR 50.59)
Is the Licensing Conclusion Acceptable?
Establish Physical Design Implement Design YES NO APPENDIX D SEE NEXT SLIDE
(Appendix B, Criterion III)
- Power System Load Analysis Calculation
- HVAC Loading Calculation
- Cable Voltage Drop Calculation
- Breaker/Fuse Coordination
- Fault Current Analysis
- Instrument Uncertainty/Setpoint Calculation
- Seismic Analysis/Qualification
- EMI/RFI Analysis/Qualification
- Failure Modes and Effects Analysis
- Single Point Vulnerability Analysis
EXCERPT FROM NEI 16-16
- Establish new design requirements and/or verify existing design requirements
- Provide the technical justification for the implementation of the new design
- Support 10 CFR 50.59 conclusions (See NEI 96-07, Rev. 1, repeated references to technical/engineering information.)
USES OF TECHNICAL ANALYSES
TYPICAL DESIGN CHANGE PROCESS Perform Technical Evaluations Perform Licensing Review (i.e., apply 10 CFR 50.59)
Is the Licensing Conclusion Acceptable?
Establish Physical Design Implement Design YES NO APPENDIX D SEE NEXT SLIDE
Terminology to be Mapped APPENDIX D MAPPING TO NEI 16-16 EVALUATION QUESTION(S)
NEI 96-07, R1 / APPENDIX D TERMINOLOGY TO BE "MAPPED" LICENSING TERMINOLOGY ONLY?
NEI 16-16 TERMINOLOGY NOTES 1 & 2 ATTRIBUTABLE YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 NEGLIGIBLE/DISCERNABLE NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION 5
AS LIKELY TO HAPPEN AS THOSE PREVIOUSLY EVALUATED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION RELATED YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 6
AS LIKELY TO HAPPEN AS THOSE DESCRIBED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION
- NEI 16-16 Guidance and definitions are extracted from Draft 2, dated May 2017, and NRC comments on NEI 16-16 will not be addressed during this presentation.
- Appendix D Based on NRC Staff feedback and draft comments, some terminology used in this presentation is NOT the same as that contained in the May 16, 2017 version of Appendix D.
o CCF Credible/Not Credible will no longer be used.
o Assessment of Evaluation questions 1, 2, 5 and 6 will be based on CCF Likelihood Sufficiently Low or CCF Likelihood Not Sufficiently Low.
[See next slide]
NOTES
Discussion of Sufficiently Low Sufficiently low means much lower than the likelihood of failures that are considered in the UFSAR (e.g., single failures) and comparable to other common cause failures that are not considered in the UFSAR (e.g., design flaws, maintenance errors, calibration errors).
[
Reference:
NEI 01-01, Section 4.4.6, Page 4-20 (to be incorporated into Appendix D)]
NOTES (CONTINUED)
Terminology to be Mapped EVALUATION QUESTIONS 1 & 2 EVALUATION QUESTION(S)
NEI 96-07, R1 / APPENDIX D TERMINOLOGY TO BE "MAPPED" LICENSING TERMINOLOGY ONLY?
NEI 16-16 TERMINOLOGY NOTES 1 & 2 ATTRIBUTABLE YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 NEGLIGIBLE/DISCERNABLE NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION 5
AS LIKELY TO HAPPEN AS THOSE PREVIOUSLY EVALUATED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION RELATED YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 6
AS LIKELY TO HAPPEN AS THOSE DESCRIBED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION
FACTORS TO CONSIDER
- Use of Software
- Use of Digital Components
- Creation of Software CCF (SCCF)*
- Intended Benefits
- Design Attributes/Features
- Only this factor will be addressed.
EVALUATION QUESTIONS 1 & 2
- 50.59 Term: Attributable o Licensing terminology only [
Reference:
NEI 96-07, Rev. 1, Sections 4.3.1 and 4.3.2]
o Used as part of the qualitative assessment to determine if an impact on the accident frequency/malfunction likelihood is due to the activity itself and not something else
EVALUATION QUESTIONS 1 & 2
- 50.59 Term: Negligible/Discernable o Licensing terminology [
Reference:
NEI 96-07, Rev. 1, Sections 4.3.1 and 4.3.2], with associated technical terminology in NEI 16-16 o Used as part of the qualitative assessment to assess the magnitude of an impact on the accident frequency/malfunction likelihood due to the activity
- Mapping to NEI 16-16 o CCF Not Credible (Definition 2.5) o CCF Susceptibility Analysis (Section 4.2.2.2)
EVALUATION QUESTIONS 1 & 2
EVALUATION QUESTIONS 1 & 2 ASSESSMENT OF NEGLIGIBLE/DISCERNABLE
- Assess the impact of the likelihood of a CCF on the accident frequency/malfunction likelihood.
- From the CCF Susceptibility Analysis, identify the likelihood of a CCF outcome (NEI 16-16, Section 4.2.2.2) o NOT CREDIBLE (Definition 2.5) A CCF can be considered not credible only if the likelihood of a CCF caused by an I&C failure source is no greater than the likelihood of a CCF caused by other failure sources that are not considered in a deterministic safety analysis described in the [U]FSAR.
EVALUATION QUESTIONS 1 & 2
- If the NEI 16-16, Section 4.2.2.2 outcome is NOT CREDIBLE, then for Appendix D, the magnitude of an impact on the accident frequency/
malfunction likelihood due to the Creation of a SCCF factor is sufficiently low.
- With an Appendix D assessment of sufficiently low, the conclusion regarding the increase in magnitude due to the Creation of a SCCF factor is negligible.
[NOTE: Assessment of the other four factors still needs to be performed to determine of overall qualitative impact on accident frequency/malfunction likelihood.]
EVALUATION QUESTIONS 1 & 2
- If the NEI 16-16, Section 4.2.2.2 outcome is CREDIBLE, then for Appendix D, the magnitude of an impact on the accident frequency/
malfunction likelihood due to the Creation of a SCCF factor is NOT sufficiently low.
- With an Appendix D assessment of NOT sufficiently low, the conclusion regarding the increase in magnitude due to the Creation of a SCCF factor needs to be assessed using the discernable criterion.
[NOTE: Assessment of the other four factors still needs to be performed to determine of overall qualitative impact on accident frequency/malfunction likelihood.]
EVALUATION QUESTIONS 1 & 2
EVALUATION QUESTION 5 Terminology to be Mapped EVALUATION QUESTION(S)
NEI 96-07, R1 / APPENDIX D TERMINOLOGY TO BE "MAPPED" LICENSING TERMINOLOGY ONLY?
NEI 16-16 TERMINOLOGY NOTES 1 & 2 ATTRIBUTABLE YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 NEGLIGIBLE/DISCERNABLE NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION 5
AS LIKELY TO HAPPEN AS THOSE PREVIOUSLY EVALUATED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION RELATED YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 6
AS LIKELY TO HAPPEN AS THOSE DESCRIBED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION
- 50.59 Term: As likely to happen as o Licensing terminology, with associated technical terminology in NEI 16-16 o Used as part of the assessment to determine if the possibility for an accident of a different type has been created
- Mapping to NEI 16-16 o CCF Not Credible (Definition 2.5) o CCF Susceptibility Analysis (Section 4.2.2.2)
EVALUATION QUESTION 5
- To Assess As likely to happen as o Identify the likelihood of a CCF outcome from NEI 16-16 o Assess the impact of the likelihood of a CCF on the creation of a possible accident of a different type
- The scope of possible accidents must be credible in the sense of having been created within the range of assumptions previously considered in the licensing basis (e.g., random single failure, loss of off-site power, etc.).
[
Reference:
NEI 96-07, Rev. 1, Section 4.3.5]
EVALUATION QUESTION 5
- From the CCF Susceptibility Analysis, identify the likelihood of a CCF outcome (NEI 16-16, Section 4.2.2.2) o NOT CREDIBLE (Definition 2.5) A CCF can be considered not credible only if the likelihood of a CCF caused by an I&C failure source is no greater than the likelihood of a CCF caused by other failure sources that are not considered in a deterministic safety analysis described in the [U]FSAR.
EVALUATION QUESTION 5
- If the NEI 16-16, Section 4.2.2.2 outcome is NOT CREDIBLE, then for Appendix D, the impact on the creation of a possible accident of a different type is sufficiently low.
- With an Appendix D assessment of sufficiently low, the conclusion that the creation of a possible accident of a different type due to a CCF is not as likely to happen as those previously evaluated in the UFSAR (i.e., is not credible). [NOTE: The Bounded/Related criteria are not applied in this case.]
EVALUATION QUESTION 5
- If the NEI 16-16, Section 4.2.2.2 outcome is CREDIBLE, then for Appendix D, the impact on the creation of a possible accident of a different type is NOT sufficiently low.
- With an Appendix D assessment of NOT sufficiently low, the conclusion that the creation of a possible accident of a different type due to a CCF is as likely to happen as those previously evaluated in the UFSAR (i.e., is credible).
[NOTE: The Bounded/Related criteria are applied in this case.]
EVALUATION QUESTION 5
- 50.59 Term: Bounded o Licensing terminology [
Reference:
NEI 96-07, Rev. 1, Section 4.3.5], with similarly-worded technical terminology in NEI 16-16 o Used as part of the assessment to determine if the possibility for an accident of a different type has been created
- Mapping to NEI 16-16 Bounded (Definition 2.2)
EVALUATION QUESTION 5
EVALUATION QUESTION 5 DEFINITIONS
- NEI 16-16, Definition 2.2, BOUNDED A bounded conclusion means that the plant-level results of the CCF malfunction are no worse than the plant-level results of other malfunctions that have been previously analyzed in the [U]FSAR.
- NEI 96-07, Rev. 1, Section 4.3.5 Accidents of a different type are credible accidents that the proposed activity could create that are not bounded by UFSAR-evaluated accidents. (NOTE:
Using this excerpt, bounded refers to accidents currently evaluated in the UFSAR.)
==
Conclusion:==
NEI 16-16 usage NEI 96-07 usage
- 50.59 Term: Related o Licensing terminology only [
Reference:
NEI 96-07, Rev. 1, Section 4.3.5]
o Used as part of the assessment to determine if the possibility for an accident of a different type has been created
EVALUATION QUESTION 5
EVALUATION QUESTION 6 Terminology to be Mapped EVALUATION QUESTION(S)
NEI 96-07, R1 / APPENDIX D TERMINOLOGY TO BE "MAPPED" LICENSING TERMINOLOGY ONLY?
NEI 16-16 TERMINOLOGY NOTES 1 & 2 ATTRIBUTABLE YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 NEGLIGIBLE/DISCERNABLE NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION 5
AS LIKELY TO HAPPEN AS THOSE PREVIOUSLY EVALUATED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION RELATED YES N/A NO EQUIVALENT TECHNICAL TERM IN NEI 16-16 6
AS LIKELY TO HAPPEN AS THOSE DESCRIBED IN THE UFSAR NO ASSOCIATED TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION BOUNDED NO SIMILAR TERMINOLOGY EXISTS ADDRESSED IN PRESENTATION
- 50.59 Term: As likely to happen as o Licensing terminology, with associated technical terminology in NEI 16-16 o Used as part of the assessment to determine if the possibility for a malfunction with a different result has been created
- Mapping to NEI 16-16 o CCF Not Credible (Definition 2.5) o CCF Susceptibility Analysis (Section 4.2.2.2)
EVALUATION QUESTION 6
- To Assess As likely to happen as o Identify the likelihood of a CCF outcome from NEI 16-16 o Assess the impact of the likelihood of a CCF on the creation of a possible malfunction with a different result
- The possible malfunctions with a different result are limited to those that are as likely to happen as those described in the UFSAR. [
Reference:
NEI 96-07, Rev. 1, Section 4.3.6]
EVALUATION QUESTION 6
- From the CCF Susceptibility Analysis, identify the likelihood of a CCF outcome (NEI 16-16, Section 4.2.2.2) o NOT CREDIBLE (Definition 2.5) A CCF can be considered not credible only if the likelihood of a CCF caused by an I&C failure source is no greater than the likelihood of a CCF caused by other failure sources that are not considered in a deterministic safety analysis described in the [U]FSAR.
EVALUATION QUESTION 6
- If the NEI 16-16, Section 4.2.2.2 outcome is NOT CREDIBLE, then for Appendix D, the impact on the creation of a possible malfunction with a different result is sufficiently low.
- With an Appendix D assessment of sufficiently low, the conclusion that the creation of a possible malfunction with a different result due to a CCF is not as likely to happen as those previously evaluated in the UFSAR (i.e., is not credible).
[NOTE: The Bounded criterion is not applied in this case.]
EVALUATION QUESTION 6
- If the NEI 16-16, Section 4.2.2.2 outcome is CREDIBLE, then for Appendix D, the impact on the creation of a possible malfunction with a different result is NOT sufficiently low.
- With an Appendix D assessment of NOT sufficiently low, the conclusion that the creation of a possible malfunction with a different result due to a CCF is as likely to happen as those previously evaluated in the UFSAR (i.e., is credible). [NOTE: The Bounded criterion is applied in this case.]
EVALUATION QUESTION 6
- 50.59 Term: Bounded o Licensing terminology [
Reference:
NEI 96-07, Rev. 1, Section 4.3.6], with similarly-worded technical terminology in NEI 16-16 o Used as part of the assessment to determine if a possible malfunction with a different result has been created
- Mapping to NEI 16-16 Bounded (Definition 2.2)
EVALUATION QUESTION 6
EVALUATION QUESTION 6 DEFINITIONS
- NEI 16-16, Definition 2.2, BOUNDED A bounded conclusion means that the plant-level results of the CCF malfunction are no worse than the plant-level results of other malfunctions that have been previously analyzed in the [U]FSAR.
- NEI 96-07, Rev. 1, Section 4.3.6 Malfunctions of SSCs are generally postulated as potential single failures to evaluate plant performance. [NOTE: Using this excerpt, bounded refers to plant performance, which is the same as plant-level result(s).]
Intent: NEI 16-16 usage = NEI 96-07 usage
- NEI 96-07, Rev. 1, Section 1.2.4 10 CFR 50.59 controls changes to both 10 CFR 50.2 design bases and supporting design information contained in the UFSAR.
- NEI 96-07, Rev. 1, Section 4.3.8 The UFSAR contains design and licensing basis information for a nuclear power facility, including description on how regulatory requirements for design are met and how the facility responds to various design basis accidents and events.
- Unless required by Regulation (e.g., SBO per 50.63), beyond design basis conditions are not considered in a licensees UFSAR.
DESIGN BASIS
- NEI 16-16, Definition 2.4, CCF BEYOND DESIGN BASIS For this guideline, a CCF beyond the design basis conclusion is used only to determine the method and acceptance criteria for the analysis of a CCF malfunction result, not to preclude the need for that analysis.
- NEI 16-16, Definition 2.1, BEST ESTIMATE METHOD A method of analysis that can employ realistic/nominal initial plant conditions and equipment performance, relaxed acceptance criteria, no other assumed equipment failures, credit for beneficial control system action as well as credit for operator actions not described in the [U]FSAR, and allows conclusions based on qualitative expert judgment or quantitative analysis. Best estimate methods can be applied when a CCF is concluded to be beyond design basis.
BEYOND DESIGN BASIS
(BEYOND) DESIGN BASIS
SUMMARY
& CONCLUSION
- NEI 16-16 terminology refers to the selection of numerical analyses and the assumptions, inputs and acceptance criteria applied to the computational results.
- NEI 96-07, Rev. 1 terminology refers to the information contained in the UFSAR to satisfy 10 CFR 50.2.
NEI 16-16 terminology NEI 96-07 terminology
QUESTIONS / COMMENTS / FEEDBACK